null Skip to main content

Dent Instruments PS48HD-P-D-N : PowerScout 48 HD Multi-Circuit Power Submeter, 48-Channel, BACnet/Modbus, Mounting Plate with Display

Dent Instruments

MSRP: $3,095.00
Your Price:  $2,073.50
(You save $1,021.50 )
(No reviews yet) Write a Review
SKU:
PS48HD-P-D-N
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
Channels48 Channels
Service1Φ / 3Φ (WYE & Delta)
CapacityUp to 16 x 3Φ / 48 x 1Φ
AccuracyANSI C12.20-2010 Class 0.2
ProtocolsBACnet & Modbus
ConnectivityEthernet + RS-485
MountingMounting Plate
DisplayYes (4-line tri-color)

PS48HD-P-D-N — PowerScout 48 HD Multi-Circuit Power Submeter

The Dent Instruments PS48HD-P-D-N is the PowerScout 48 HD, DENT's networked 48-channel, three-phase submeter. The PS48HD-P-D-N measures voltage, current, power, energy, and many other electrical parameters on any combination of single- and three-phase loads — up to 16 three-phase or 48 single-phase circuits across two voltage references — and can network with other PowerScout HD meters to cover multiple loads across a facility.

Looking ahead? The PowerScout FLEX 48 is DENT's next-generation replacement for the PowerScout HD — faster commissioning with FLEXPoint™, browser-based FLEXPoint™ GO, flexible Virtual Meters, and 7.2 kHz sampling.

See the PowerScout FLEX 48 →

The PS48HD-P-D-N delivers revenue-grade performance with 1.8 kHz sampling, a 1-second update rate, and ANSI C12.20-2010 Class 0.2 accuracy (depending on CT). It supports both Modbus (SunSpec IEEE-754) and BACnet over RS-485 or Ethernet, includes four digital pulse inputs, and provides a 12 VDC auxiliary output. DENT's patented PhaseChek™ circuitry (U.S. Patent 7,612,552) confirms correct CT orientation during commissioning.

Built as a UL-Recognized circuit board on a mounting plate, the PS48HD-P-D-N is delivered in the Mounting Plate configuration and is configured through ViewPoint HD PC software or a web browser. It operates as an endpoint reporting to a building management system, RTU, data acquisition device, or DENTCloud™ host.

Best for

  • High-density tenant and accountability submetering — up to 48 circuits from one device
  • Bi-directional metering and demand-response monitoring
  • Real-time power monitoring of building mains and equipment loads
  • Networked metering of many loads alongside other PowerScout HD meters
  • Projects requiring Made in USA / BAA / TAA equipment

Key Features

Revenue-Grade Accuracy + PhaseChek™

The PS48HD-P-D-N meets ANSI C12.20-2010 Class 0.2 revenue-grade accuracy (dependent on CT) with NIST-traceable calibration, and patented PhaseChek™ circuitry (U.S. Patent 7,612,552) flags mis-phased or backwards CTs during commissioning.

Dual-Protocol + 4 Pulse Inputs

The PS48HD-P-D-N communicates over Modbus (SunSpec IEEE-754) or BACnet using RS-485 or Ethernet (Modbus RTU, BACnet MS/TP, Modbus TCP, or BACnet IP) and adds four digital pulse inputs for gas, water, or other meters.

48 Channels, One Device

Meter up to 16 three-phase or 48 single-phase circuits across two voltage references from a single PS48HD-P-D-N, reducing hardware and panel space versus single-circuit meters.

ViewPoint HD Setup

Configure the PS48HD-P-D-N from ViewPoint HD or a web browser, scan the network to find and name every PowerScout HD meter, and pre-build configuration templates — even without the meter on hand — for fast, repeatable deployment.

Universal CT Compatibility

Use the PS48HD-P-D-N with DENT 333 mV Split Core or RōCoil™ (Rogowski) CTs, including revenue-grade options, measuring up to 4000 A depending on the CT selected.

Made in USA, BAA & TAA Compliant

Per the DENT data sheet, the PowerScout 48 HD is Made in USA and marked Buy American Act (BAA) and TAA compliant, supporting government, healthcare, and institutional procurement requirements.

Technical Specifications

SpecificationPS48HD-P-D-N
Model / Part NumberPS48HD-P-D-N
SeriesPowerScout 48 HD (48-channel, 3-phase)
Channel CapacityUp to 16 three-phase or 48 single-phase circuits; 2 voltage references
Service TypeSingle Phase, Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta)
PowerFrom L1 Phase to L2 Phase. 90-600 VAC RMS, CAT III, 50/60 Hz, 500 mA AC Max
Auxiliary Power OutUnregulated 12 VDC, 200 mA, self-resetting fuse (requires 100 VAC minimum input)
AC Protection0.5 A fuse, 200 kA interrupt capacity
Voltage Channels90-346 VAC Line-to-Neutral, 600 V Line-to-Line, CAT III; two voltage reference inputs
Current Channels48 channels, 0.525 VAC max, 333 mV CTs, 0-4000 A depending on CT
Maximum Current Input150% of CT rating (mV CTs) to maintain accuracy; up to 4000 A with RōCoil CTs
Pulse Inputs4 inputs to a customer dry-contact pulse output; max pulse rate 10 Hz (50 ms min transition)
Measurement TypeTrue RMS using high-speed DSP with continuous sampling
Accuracy0.2% — ANSI C12.20-2010 Class 0.2; NIST traceable calibration
Resolution32-bit IEEE-754 single-precision floating point
Line Frequency50/60 Hz (45-70 Hz measurable range); measured L1-N
Waveform Sampling1.8 kHz
Parameter Update Rate1.0 second
MeasurementsVolts, Amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, Import/Export/Net kWh, kVAh and kVARh, THD, Theta, Frequency — per phase and element total
Display4-line LCD with tri-color backlight
Communications HardwareRS-485, Ethernet, and USB (USB for configuration only)
Supported ProtocolsModbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP (Modbus based on SunSpec IEEE-754)
Communication Rate9600 (default), 19200, 38400, 57600, 76800, 115200 baud
Max Communication Length1200 m at 100K bits/second or less
Alarm OutputPhase-loss / undervoltage (open collector, 30 VDC max)
Web Page Security2 levels of PIN protection (Read/Write or Read-Only)
MountingOpen circuit board on a mounting plate for installation in the UL-approved enclosure of your choice
High-Voltage CoverNot included on mounting-plate version
EnclosureABS plastic, 94-V0 flammability rating; 1 in EMT conduit connections
Dimensions26.2 x 24.1 x 8.0 cm (10.3 x 9.5 x 3.1 in)
Wire Connections12-28 AWG, 600 VAC; voltage connection must be #14 AWG or larger and 600 VAC rated
Operating Temperature-20 to 60 °C (-4 to 140 °F)
Humidity5% to 95% non-condensing
CertificationsUL Recognized (E186827, UL 61010-1 3rd Ed.; CSA C22.2 No. 61010-1); CE (LVD EN61010-1, EMC EN61326-1); RoHS 2 (EN50581); ANSI C12.20 Class 0.2; Made in USA; BAA and TAA compliant
Configuration SoftwareViewPoint HD (Windows 7 / 8 / 10 / 11) and web browser

Documentation

Frequently Asked Questions

How many circuits can the PS48HD-P-D-N meter?

The PS48HD-P-D-N has 48 current channels and can meter up to 16 three-phase or 48 single-phase circuits, networked with other PowerScout HD meters to cover multiple loads across a facility.

What protocols does the PS48HD-P-D-N support?

The PS48HD-P-D-N supports Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP (Modbus based on SunSpec IEEE-754) over RS-485 or Ethernet, plus four digital pulse inputs.

Which current transformers work with the PS48HD-P-D-N?

The PS48HD-P-D-N uses DENT 333 mV Split Core or RōCoil™ (Rogowski) CTs, including revenue-grade options, and measures up to 4000 A depending on the CT selected.

What is the form factor of the PS48HD-P-D-N?

The PS48HD-P-D-N is supplied as a UL-Recognized circuit board on a mounting plate in the Mounting Plate configuration, measuring 26.2 x 24.1 x 8.0 cm (10.3 x 9.5 x 3.1 in).

Is the PS48HD-P-D-N revenue grade?

The PS48HD-P-D-N meets ANSI C12.20-2010 Class 0.2 revenue-grade accuracy, dependent on the CT selected, and ships with a NIST-traceable calibration.

What is the difference between the PS48HD-P-D-N and the PowerScout FLEX 48?

The PowerScout FLEX 48 is the next-generation replacement for the PowerScout 48 HD, adding FLEXPoint™ setup tools, browser-based FLEXPoint™ GO, Virtual Meters, and 7.2 kHz sampling. The PS48HD-P-D-N remains available; if you are specifying a new system, consider the PowerScout FLEX 48.

Is the PS48HD-P-D-N Made in USA?

Yes. Per the DENT data sheet the PowerScout 48 HD, including the PS48HD-P-D-N, is Made in USA and is marked BAA and TAA compliant.

Warranty

DENT Instruments, Inc. warrants that PowerScout Series instruments and accessories are free from substantial defects in material and workmanship under normal use, given proper installation and maintenance, for 5 years (60 months) from the invoice date.

More broadly, DENT Instruments promises that any product it sells is free from material defects in design, materials, or manufacturing for the period shown on that product's current data sheet, beginning from the date of manufacture. This warranty does not extend to ordinary wear and tear, or to normally replaceable components such as batteries and humidity sensor elements.

Coverage & Remedy

During the warranty period, DENT Instruments may, at its sole option, repair, replace, service, or credit any product found to be defective and returned freight prepaid by the buyer, at no charge to the buyer for the warranty repair or replacement. Refurbished material may be used. DENT covers ground shipping for advance warranty replacements; if the customer requests expedited shipping, the customer pays the difference.

The warranty remains in effect provided the product: (1) was installed, operated, and maintained properly; (2) has not been abused or misused; (3) has not been repaired, altered, or modified outside of DENT Instruments' authorized facilities; and (4) was not sold subject to other warranty terms specified at the time of sale.

Limitation & Disclaimer

This warranty replaces all other warranties, expressed or implied, including any warranties of merchantability and fitness for a particular purpose, and is the sole and exclusive remedy. In no event will DENT Instruments be liable for any special, incidental, or consequential damages or commercial losses, even if advised of the possibility. Correction of defects by repair, replacement, service, or credit at the seller's option constitutes fulfillment of all warranty obligations. All transactions are governed by the laws of the State of Oregon, U.S.A.

Warranty Service

To request warranty service, contact DENT Instruments Technical Support at 541.388.4774 or 800.388.0770, or email support@dentinstruments.com. A Returned Material Authorization (RMA) number is required before returning any product.

Product Line:
PowerScout HD
Revenue Grade:
Yes
Accuracy Class:
ANSI C12.20 Class 0.2
Communication:
Modbus RTU
Communication:
BACnet MS/TP
Current Input:
333 mV
Current Input:
Rogowski
Mounting:
Mounting Plate
Country of Origin:
USA

Videos Hide Videos Show Videos