Belimo 22ADP-55QB : Active Diff Pressure Air, 8 DIP Ranges (-0.6 to 1 inch WC), Modbus RTU + 2 Outputs (0-5V / 0-10V), Flow Output with LCD Display + Auto-Zero, NEMA 4X, 24V, 5-Yr Warranty

Belimo

MSRP: $908.00
$408.60
(You save $499.40 )
(No reviews yet) Write a Review
SKU:
22ADP-55QB
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
TypeDifferential Pressure (Air)
Range-0.6 to 1 inch WC (-150 to 250 Pa)
Output2× 0–5V / 0–10V
CommsModbus RTU + Analog
Multirange8 DIP-selectable
DisplayePaper LCD
Auto-ZeroYes
Power24 VAC/VDC

The 22ADP-55QB is a Belimo active 24V differential pressure transducer for air, with a low / sensitive pressure range of -0.6 to 1 inch WC (-150 to 250 Pa) and eight DIP-switch-selectable measuring sub-ranges. One SKU adapts to multiple applications without re-specifying a range variant. The sensor uses a piezo measuring element with ±0.02 inch WC accuracy below 2 inch WC and ±0.04 inch WC above. Two active analog outputs deliver pressure and volumetric flow (0-5V or 0-10V switch-selectable), while Modbus RTU on RS-485 exposes all values to the BAS as a native bus device. The auto-zero feature automatically compensates for sensor drift at configurable intervals — critical for low-range applications. An integrated LCD display with backlight shows live values with programmable units. The orange polycarbonate housing is rated NEMA 4X / IP65 with UL 2043 plenum compliance. A 1/2" NPT conduit adapter, mounting plate, and duct connector kit ship in the box.

Best For

HVAC differential pressure monitoring in the -0.6 to 1 inch WC range: cleanroom and laboratory differential pressure monitoring, isolation room positive/negative pressure verification, biosafety cabinet face velocity, low-velocity duct measurement, and any application where measurements below 1 inch WC require high analog resolution. Same range, different configurations: 22ADP-55Q ($596), 22ADP-55QA ($777). For medium pressure (-0.4 to 10 inch WC, filter and damper applications), see the 22ADP-554 family.

Modbus RTU Communication

This sensor communicates with the BAS via Modbus RTU on RS-485, exposing all measured values (differential pressure, volumetric flow), selected sub-range, calibration status, and configuration parameters as Modbus registers. Modbus address, baud rate, and parity are configurable. Analog 0-5V/0-10V backup outputs remain available alongside.

Auto-Zero Feature

An internal solenoid valve periodically isolates the sensor from the pressure ports and re-zeros the reading automatically at a configurable interval. This eliminates the typical drift that affects piezo sensors at low pressure ranges, removing the need for frequent manual zero-point calibration. Especially valuable at the most sensitive sub-ranges (S5–S7) where a small offset translates to a large percentage error.

Manual Zero-Point Calibration

After initial commissioning, perform manual zero-point calibration to set the sensor's reference offset. Recommended interval depends on the active sub-range: ‚â§1 inch WC: every 3 months; ‚â§2 inch WC: every 6 months; >2 inch WC: every 12 months. Procedure: power the sensor for at least 15 minutes, release both tube connectors from the + and - pressure ports (calibration is required even if display reads 0), press and hold the calibration button until the LED illuminates steadily, then wait for the LED to flash and reinstall the tubes (observing + and - polarity). Note: this SKU also has the auto-zero feature that handles routine zero-point correction automatically — manual calibration is needed less frequently as a result.

5-YEAR WARRANTY
Backed by Belimo's industry-leading 5-year factory warranty. ZOT Supply is an authorized Belimo distributor with fast nationwide and international shipping — every unit ships factory-tested with full warranty support.

Key Features

Auto-Zero + LCD Display

Combines automatic zero-point correction (eliminates routine manual calibration drift) with an on-housing LCD display for live pressure and flow readout. Top-of-the-line variant for low-range and critical applications where both maintenance reduction and on-wall visibility matter.

8 DIP-Selectable Measuring Sub-Ranges

One SKU covers eight pressure ranges within the -0.6 to 1 inch WC envelope, selectable via on-board DIP switch. Narrower sub-ranges give higher analog resolution — particularly valuable for low-velocity filter monitoring and cleanroom applications. Settings can also be changed remotely via the bus.

Piezo Sensing Element with ±0.02 inch WC Accuracy

Belimo's proven piezo measuring element with ±0.02 inch WC accuracy below 2 inch WC and ±0.04 inch WC above. Long-term stability ±2.5% FSO over 4 years. Covers low-velocity duct measurements where a thermal-mass element would be too noisy.

160 inch WC Burst Pressure

Burst pressure tolerance of 160 inch WC (40 kPa) — survives transient overpressure events from damper closures, fan starts, and pressure tests without damage.

Volumetric Flow Output

Channel 2 outputs volumetric flow calculated from differential pressure and a configured K-factor. Selectable units: m³/h, m³/s, or cfm. Default range 0-750,000 cfm. Eliminates the need for a separate flow meter when the application has a known venturi or orifice K-factor.

NEMA 4X / IP65 + UL 2043 Plenum Rated

UV-resistant orange polycarbonate housing rated NEMA 4X / IP65 (UL Enclosure Type 4X). UL 2043 plenum compliant for return-air ducts. UL94 5VA flame class. NBR70 seal for chemical resistance against typical HVAC environment exposures.

5-Year Belimo Warranty

Industry-leading factory warranty backed by Belimo's worldwide service network.

Selectable Measuring Sub-Ranges (DIP Switch S0–S7)

The active measuring sub-range is set via on-board DIP switch (settings S0 through S7) or remotely via the bus. The factory default is S0 (full range); narrow the range to higher S-numbers for low-velocity applications where higher analog resolution matters.

Settinginch WCPaNote
S00–1 inch WC0–250 Pa‚òÖ Factory setting
S10–0.8 inch WC0–200 Pa
S20–0.6 inch WC0–150 Pa
S30–0.4 inch WC0–100 Pa
S40–0.2 inch WC0–50 Pa
S50–0.1 inch WC0–25 Pa
S60–0.04 inch WC0–10 Pa
S7-0.6–1 inch WC-150–250 PaFull bidirectional, factory commissioning

Technical Specifications

SpecificationDetail
Sensor StyleActive differential pressure transducer for air
Measured ValuesDifferential pressure, Volumetric flow
Measuring FluidAir and other non-aggressive, non-flammable gases
Sensing ElementPiezo measuring element
Output Signals2× active analog: Output 1 = Pressure, Output 2 = Volumetric Flow; 0-5V or 0-10V switch-selectable
Output Loadmin. 10 kΩ load resistance
CommunicationModbus RTU (RS-485)
Modbus ConfigurationAddress, baud rate, parity configurable via Modbus
Pressure Measuring Range (Default)-0.6 to 1 inch WC (-150 to 250 Pa) — DIP setting S0
Pressure Measuring Range (Selectable)8 sub-ranges via DIP switch S0–S7 within the low / sensitive pressure envelope
Pressure DirectionBidirectional
Pressure Accuracy‚â§2 inch WC: ±0.02 inch WC; >2 inch WC: ±0.04 inch WC
Long-Term Stability±2.5% FSO (Full Scale Output) per 4 years
Burst Pressure160 inch WC (40 kPa)
Volumetric Flow RangeDefault 0-750,000 cfm; configurable via Modbus
Volumetric Flow Unitsm³/h, m³/s, or cfm (parameterizable)
Typical Response TimeAdjustable: 0.8 s or 4.0 s
Manual Zero-Point CalibrationSingle-button with LED feedback; recommended every 3-12 months depending on range
Auto-Zero FeatureYes — internal solenoid valve periodically re-zeros at configurable interval
ApplicationAir monitoring — duct-mounted
MountingWall/duct mount with included A-22D-A10 mounting plate
Pressure ConnectionTwo ports (+/-) with included A-22AP-A08 duct connector kit (PVC tube + connectors)
Conduit1/2" NPT conduit adapter included; cable gland 2x ø6 mm with strain relief
Power Supply24 VAC/VDC (19-29 VAC, 15-35 VDC)
Power Consumption4.3 VA AC / 2.3 W DC
Electrical ConnectionPluggable spring-loaded terminal block, max 2.5 mm²
DisplayLCD 1.14×1.38" (29×35 mm) with backlight; programmable units (Pa, inch WC; m¬≥/h, m¬≥/s, cfm)
Housing MaterialPolycarbonate, orange — UL94 5VA, UV-resistant; NBR70 seal
Enclosure RatingNEMA 4X / IP65, UL Enclosure Type 4X
UL 2043 Plenum ComplianceSuitable for use in air plenums per NEC 300.22(C) and IMC Section 602
Protection ClassIEC/EN III, SELV (Safety Extra-Low Voltage)
Power Source ULClass 2 Supply
Pollution Degree3
Ambient HumidityMax. 95% RH, non-condensing
Ambient Temperature14-122°F (-10 to 50°C)
Fluid Temperature15-120°F (-10 to 50°C)
Storage Temperature-4 to 176°F (-20 to 80°C)
EU ConformityCE Marking
CertificationIEC/EN 60730-1 and IEC/EN 60730-2-6
Quality StandardISO 9001
ManufacturerBelimo
Manufacturer Part Number22ADP-55QB
Warranty5-year factory warranty

What's In the Box

Parts Included
  • 22ADP-55QB differential pressure transducer with LCD display with auto-zero feature in orange polycarbonate housing
  • A-22D-A10 mounting plate (L housing)
  • A-22AP-A08 duct connector kit — 2 m PVC tube, 2× plastic duct connectors
  • Cable gland with strain relief, ø6...8 mm
  • 1/2" NPT conduit adapter, 2× ø6 mm
  • Mounting dowels and screws

Compatible accessories sold separately: A-22AP-A01 metal duct connector (1.5" L, 0.2" tube connection) for steel ducts where the included plastic connectors are not preferred.

Documentation

Frequently Asked Questions

What does the 22ADP-55QB measure and output?

It measures differential air pressure (between the + and - ports) and outputs volumetric flow calculated from that pressure plus a configured K-factor. Two analog outputs: AO1 = pressure, AO2 = flow, both switch-selectable between 0-5V and 0-10V. All values are also exposed via Modbus RTU on RS-485.

Why 8 measuring ranges? Which to use?

The 8 sub-ranges (S0–S7) let one sensor body cover applications across the -0.6 to 1 inch WC envelope. Choose the narrowest range that covers your expected reading — narrower ranges give higher analog resolution. Set via DIP switch or remotely via Modbus RTU.

How does the Auto-Zero feature work?

An internal solenoid valve briefly isolates the sensor from the pressure ports at a configurable interval, reads its own zero reference, and updates the offset correction. Eliminates the drift that affects piezo sensors at low ranges — especially important for cleanroom/lab applications where a 0.05 inch WC offset would be a 5-50% reading error. Belimo still recommends annual manual zero-point verification.

What does the LCD display show?

The 1.14×1.38" backlit LCD cycles through differential pressure (Pa or inch WC) and volumetric flow (m¬≥/h, m¬≥/s, or cfm). Status icons show fault state, service due, and current sub-range. Useful for commissioning and service-call diagnostics without a laptop.

How is volumetric flow calculated?

Volumetric flow Q = K × ‚àö(ŒîP), where K is a K-factor specific to your venturi, orifice plate, or pitot tube. K-factor is set via Modbus RTU. Default 0-750,000 cfm full scale. Without a known K-factor, use only AO1 (pressure).

What is the burst pressure rating?

160 inch WC (40 kPa). Survives transient overpressure events (fan starts, damper closures, pressure tests) without calibration drift or seal damage.

How often is manual calibration needed?

Interval depends on active sub-range: 3 months at S5-S7 (‚â§1 inch WC), 6 months at S3/S4 (‚â§2 inch WC), 12 months at S0-S2 (>2 inch WC). Lower ranges drift more noticeably. Auto-Zero on this variant handles routine correction automatically.

How is this different from other 22ADP variants?

All 22ADP variants share the same chassis and piezo element. This SKU is the low / sensitive-range variant (-0.6 to 1 inch WC). Other ranges: 22ADP-554 (medium, -0.4 to 10 inch WC); 22ADP-556 (high, 0 to 28 inch WC). Output styles: -58x = V+mA analog only, -55x = V + Modbus RTU, -56x = V + BACnet MS/TP. Choose by BAS protocol and range.

Where can I install this sensor?

Wall or duct mount indoors, NEMA 4X / IP65. UL 2043 plenum compliant for return-air ducts (NEC 300.22(C)). Operating: 14-122°F ambient, 15-120°F fluid. Mounting plate and duct connector kit (2 m PVC tubing) included.

Power requirements?

24 VAC or 24 VDC (19-29 VAC, 15-35 VDC). Power consumption 4.3 VA AC / 2.3 W DC — compatible with standard 24V control transformers shared with actuators.

Sensor Type:
Differential Pressure / Air
Sensing Element:
Piezo
Output Signal:
Pressure + Volumetric Flow
Output Style:
Active Transmitter (V) + Modbus RTU
Output Voltage Options:
0-5V / 0-10V
Power:
24 VAC/VDC
Number of Outputs:
2 analog
Pressure Range (Default):
-0.6 to 1 inch WC (-150 to 250 Pa)
Pressure Range Variant:
Low / Sensitive
Multi-Range:
8 DIP-selectable sub-ranges
Pressure Direction:
Bidirectional
Pressure Accuracy:
±0.02 inch WC (‚â§2 in WC range), ±0.04 inch WC (>2 in WC)
Burst Pressure:
160 inch WC (40 kPa)
Volumetric Flow Output:
Yes (default 0-750,000 cfm)
Auto-Zero:
Yes
Display:
LCD with Backlight
Supported Protocols:
Modbus RTU + Analog
Mounting:
Duct/Wall (Indoor)
Conduit:
1/2 NPT (included)"
Enclosure:
NEMA 4X / IP65 / UL 2043 Plenum