null Skip to main content

Belimo 22ADP-584 : Active Differential Pressure Transducer for Air, Piezo Element, 8 DIP-Selectable Ranges (-0.4 to 10 inch WC), 2 Analog Outputs (0–5V / 0–10V / 4–20 mA), Volumetric Flow Output, NEMA 4X / IP65, 24 VAC/VDC, 5-Year Warranty

Belimo

MSRP: $487.00
$219.15
(You save $267.85 )
(No reviews yet) Write a Review
SKU:
22ADP-584
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
TypeDifferential Pressure (Air)
Range-0.4 to 10 inch WC (-100 to 2500 Pa)
Output2× 0–5V / 0–10V / 4–20 mA
CommsAnalog only (no bus)
Multirange8 DIP-selectable
DisplayNo display
Power24 VAC/VDC

The 22ADP-584 is a Belimo active 24V differential pressure transducer for air, with a medium pressure range of -0.4 to 10 inch WC (-100 to 2500 Pa) and eight DIP-switch-selectable measuring sub-ranges. One SKU adapts to multiple applications without re-specifying a range variant. The sensor uses a piezo measuring element with ±0.02 inch WC accuracy below 2 inch WC and ±0.04 inch WC above. Two active analog outputs deliver pressure and volumetric flow — switch-selectable between 0-5V, 0-10V, and 4-20 mA. Analog-only variant: no bus communication. The orange polycarbonate housing is rated NEMA 4X / IP65 with UL 2043 plenum compliance. A 1/2" NPT conduit adapter, mounting plate, and duct connector kit ship in the box.

Best For

HVAC differential pressure monitoring in the -0.4 to 10 inch WC range: filter status (clogged-filter alarms at 0.5-1 inch WC delta-P), fan V-belt slippage detection, smoke/fire damper position verification, and general duct static pressure for pressure-independent VAV control. Same range, different configurations: 22ADP-554 ($596), 22ADP-584A ($623). For higher pressure (up to 28 inch WC), see the 22ADP-556 family. For lower / more sensitive (-0.6 to 1 inch WC, cleanroom/lab), see the 22ADP-55Q family.

Manual Zero-Point Calibration

After initial commissioning, perform manual zero-point calibration to set the sensor's reference offset. Recommended interval depends on the active sub-range: ≤1 inch WC: every 3 months; ≤2 inch WC: every 6 months; >2 inch WC: every 12 months. Procedure: power the sensor for at least 15 minutes, release both tube connectors from the + and - pressure ports (calibration is required even if display reads 0), press and hold the calibration button until the LED illuminates steadily, then wait for the LED to flash and reinstall the tubes (observing + and - polarity).

5-YEAR WARRANTY
Backed by Belimo's industry-leading 5-year factory warranty. ZOT Supply is an authorized Belimo distributor with fast nationwide and international shipping — every unit ships factory-tested with full warranty support.

Key Features

Universal Output (V or mA)

Two analog outputs switch-selectable between 0-5V, 0-10V, AND 4-20 mA. Works with any BAS controller — voltage inputs for short runs, 4-20 mA current loops for long cable runs or harsh electrical environments. No need to spec a different SKU for V vs mA applications.

8 DIP-Selectable Measuring Sub-Ranges

One SKU covers eight pressure ranges within the -0.4 to 10 inch WC envelope, selectable via on-board DIP switch. Narrower sub-ranges give higher analog resolution — particularly valuable for low-velocity filter monitoring and cleanroom applications.

Piezo Sensing Element with ±0.02 inch WC Accuracy

Belimo's proven piezo measuring element with ±0.02 inch WC accuracy below 2 inch WC and ±0.04 inch WC above. Long-term stability ±2.5% FSO over 4 years. Covers low-velocity duct measurements where a thermal-mass element would be too noisy.

160 inch WC Burst Pressure

Burst pressure tolerance of 160 inch WC (40 kPa) — survives transient overpressure events from damper closures, fan starts, and pressure tests without damage.

Volumetric Flow Output

Channel 2 outputs volumetric flow calculated from differential pressure and a configured K-factor. Selectable units: m³/h, m³/s, or cfm. Default range 0-750,000 cfm. Eliminates the need for a separate flow meter when the application has a known venturi or orifice K-factor.

NEMA 4X / IP65 + UL 2043 Plenum Rated

UV-resistant orange polycarbonate housing rated NEMA 4X / IP65 (UL Enclosure Type 4X). UL 2043 plenum compliant for return-air ducts. UL94 5VA flame class. NBR70 seal for chemical resistance against typical HVAC environment exposures.

5-Year Belimo Warranty

Industry-leading factory warranty backed by Belimo's worldwide service network.

Selectable Measuring Sub-Ranges (DIP Switch S0–S7)

The active measuring sub-range is set via on-board DIP switch (settings S0 through S7). The factory default is S0 (full range); narrow the range to higher S-numbers for low-velocity applications where higher analog resolution matters.

Settinginch WCPaNote
S00–10 inch WC0–2500 Pa★ Factory setting
S10–8 inch WC0–2000 Pa
S20–6 inch WC0–1500 Pa
S30–4 inch WC0–1000 Pa
S40–2 inch WC0–500 Pa
S50–1 inch WC0–250 Pa
S60–0.4 inch WC0–100 Pa
S7-0.4–0.4 inch WC-100–100 PaBidirectional, most sensitive

Technical Specifications

SpecificationDetail
Sensor StyleActive differential pressure transducer for air
Measured ValuesDifferential pressure, Volumetric flow
Measuring FluidAir and other non-aggressive, non-flammable gases
Sensing ElementPiezo measuring element
Output Signals2× active analog: Output 1 = Pressure, Output 2 = Volumetric Flow; 0-5V, 0-10V, or 4-20 mA switch-selectable
Output Loadmin. 10 kΩ load resistance; mA output: max. 500 Ω loop resistance
Pressure Measuring Range (Default)-0.4 to 10 inch WC (-100 to 2500 Pa) — DIP setting S0
Pressure Measuring Range (Selectable)8 sub-ranges via DIP switch S0–S7 within the medium pressure envelope
Pressure DirectionBidirectional
Pressure Accuracy≤2 inch WC: ±0.02 inch WC; >2 inch WC: ±0.04 inch WC
Long-Term Stability±2.5% FSO (Full Scale Output) per 4 years
Burst Pressure160 inch WC (40 kPa)
Volumetric Flow RangeDefault 0-750,000 cfm; configurable
Volumetric Flow Unitsm³/h, m³/s, or cfm (parameterizable)
Typical Response TimeAdjustable: 0.8 s or 4.0 s
Manual Zero-Point CalibrationSingle-button with LED feedback; recommended every 3-12 months depending on range
Auto-Zero FeatureNo (manual zero-point calibration only)
ApplicationAir monitoring — duct-mounted
MountingWall/duct mount with included A-22D-A10 mounting plate
Pressure ConnectionTwo ports (+/-) with included A-22AP-A08 duct connector kit (PVC tube + connectors)
Conduit1/2" NPT conduit adapter included; cable gland 2x ø6 mm with strain relief
Power Supply24 VAC/VDC (19-29 VAC, 15-35 VDC)
Power Consumption4.3 VA AC / 2.3 W DC
Electrical ConnectionPluggable spring-loaded terminal block, max 2.5 mm²
DisplayNo display on this variant
Housing MaterialPolycarbonate, orange — UL94 5VA, UV-resistant; NBR70 seal
Enclosure RatingNEMA 4X / IP65, UL Enclosure Type 4X
UL 2043 Plenum ComplianceSuitable for use in air plenums per NEC 300.22(C) and IMC Section 602
Protection ClassIEC/EN III, SELV (Safety Extra-Low Voltage)
Power Source ULClass 2 Supply
Pollution Degree3
Ambient HumidityMax. 95% RH, non-condensing
Ambient Temperature14-122°F (-10 to 50°C)
Fluid Temperature15-120°F (-10 to 50°C)
Storage Temperature-4 to 176°F (-20 to 80°C)
EU ConformityCE Marking
CertificationIEC/EN 60730-1 and IEC/EN 60730-2-6
Quality StandardISO 9001
ManufacturerBelimo
Manufacturer Part Number22ADP-584
Warranty5-year factory warranty

What's In the Box

Parts Included
  • 22ADP-584 differential pressure transducer in orange polycarbonate housing
  • A-22D-A10 mounting plate (L housing)
  • A-22AP-A08 duct connector kit — 2 m PVC tube, 2× plastic duct connectors
  • Cable gland with strain relief, ø6...8 mm
  • 1/2" NPT conduit adapter, 2× ø6 mm
  • Mounting dowels and screws

Compatible accessories sold separately: A-22AP-A01 metal duct connector (1.5" L, 0.2" tube connection) for steel ducts where the included plastic connectors are not preferred.

Documentation

Frequently Asked Questions

What does the 22ADP-584 measure and output?

It measures differential air pressure (between the + and - ports) and outputs volumetric flow calculated from that pressure plus a configured K-factor. Two analog outputs: AO1 = pressure, AO2 = flow, both switch-selectable between 0-5V, 0-10V, and 4-20 mA. Analog-only variant — no bus communication.

Why 8 measuring ranges? Which to use?

The 8 sub-ranges (S0–S7) let one sensor body cover applications across the -0.4 to 10 inch WC envelope. Choose the narrowest range that covers your expected reading — narrower ranges give higher analog resolution. Set via DIP switch.

Why use 4-20 mA instead of 0-10V?

4-20 mA current loops are immune to voltage drop on long cable runs (>~150 ft). The loop also has built-in fault detection: 0 mA = broken loop, vs 0V on a voltage output which could mean either zero reading OR broken wiring.

How is volumetric flow calculated?

Volumetric flow Q = K × √(ΔP), where K is a K-factor specific to your venturi, orifice plate, or pitot tube. K-factor is set via Belimo Assistant 2 / dongle. Default 0-750,000 cfm full scale. Without a known K-factor, use only AO1 (pressure).

What is the burst pressure rating?

160 inch WC (40 kPa). Survives transient overpressure events (fan starts, damper closures, pressure tests) without calibration drift or seal damage.

How often is manual calibration needed?

Interval depends on active sub-range: 3 months at S5-S7 (≤1 inch WC), 6 months at S3/S4 (≤2 inch WC), 12 months at S0-S2 (>2 inch WC). Lower ranges drift more noticeably.

How is this different from other 22ADP variants?

All 22ADP variants share the same chassis and piezo element. This SKU is the medium-range variant (-0.4 to 10 inch WC). Other ranges: 22ADP-556 (high, 0 to 28 inch WC); 22ADP-55Q (low, -0.6 to 1 inch WC). Output styles: -58x = V+mA analog only, -55x = V + Modbus RTU, -56x = V + BACnet MS/TP. Choose by BAS protocol and range.

Where can I install this sensor?

Wall or duct mount indoors, NEMA 4X / IP65. UL 2043 plenum compliant for return-air ducts (NEC 300.22(C)). Operating: 14-122°F ambient, 15-120°F fluid. Mounting plate and duct connector kit (2 m PVC tubing) included.

Power requirements?

24 VAC or 24 VDC (19-29 VAC, 15-35 VDC). Power consumption 4.3 VA AC / 2.3 W DC — compatible with standard 24V control transformers shared with actuators.

Sensor Type:
Differential Pressure / Air
Sensing Element:
Piezo
Output Signal:
Pressure + Volumetric Flow
Output Style:
Active Transmitter (V/mA)
Output Voltage Options:
0-5V / 0-10V / 4-20 mA
Power:
24 VAC/VDC
Number of Outputs:
2 analog
Pressure Range (Default):
-0.4 to 10 inch WC (-100 to 2500 Pa)
Pressure Range Variant:
Medium
Multi-Range:
8 DIP-selectable sub-ranges
Pressure Direction:
Bidirectional
Pressure Accuracy:
±0.02 inch WC (≤2 in WC range), ±0.04 inch WC (>2 in WC)
Burst Pressure:
160 inch WC (40 kPa)
Volumetric Flow Output:
Yes (default 0-750,000 cfm)
Auto-Zero:
No (manual zero-point calibration)
Display:
No Display
Supported Protocols:
Analog only (no bus)
Mounting:
Duct/Wall (Indoor)
Conduit:
1/2 NPT (included)"
Enclosure:
NEMA 4X / IP65 / UL 2043 Plenum