-
ACI
ACI CO-D-RB-D : Carbon Monoxide Sensor, 0-125 PPM Default, (250 PPM Max), Duct Mount, 4-20mA or 2-10VDC Output, LCD, Relay & Buzzer
MSRP: $1,164.00Your Price: $564.50 -
ACI
ACI CO-R-RB-D : Carbon Monoxide Sensor, 0-125 PPM Default, (250 PPM Max), Room Mount, 4-20mA, 2-10VDC Output, LCD, Relay & Buzzer
MSRP: $986.00Your Price: $478.20 -
Senva
Senva TG0R-CB : Value Room Recessed CO Sensor, 0-10 VDC Output, Relay, LED and Audible Alarms, Made in USA, 7-Year Warranty
MSRP: $651.40Your Price: $272.84 -
Senva
Senva TGM-BCN-A : Metal Wall Mount Dual Toxic Gas CO/NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, 7-Year Warranty
MSRP: $1,478.85Your Price: $619.40 -
-
-
-
-
Senva
Senva TGM-ACN-AS : Metal Wall Mount Dual Toxic Gas CO/NO2 Sensor/Controller, 0-10V, 0-5V, 1-5V and 4-20mA Selectable Output, LCD Display, Solid Cover, 7-Year Warranty
MSRP: $1,293.99Your Price: $541.98 -
-
ACI
ACI CO-R : Carbon Monoxide Sensor, 0-125 PPM Default, (250 PPM Max), Room Mount, 4-20mA, 2-10VDC Output
MSRP: $807.00Your Price: $391.40 -
-
-
Senva
Senva TGD-BCX-AS : Duct Mount Toxic Gas CO Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, Solid/Opaque Enclosure, 7-Year Warranty
MSRP: $1,016.72Your Price: $425.84 -
-
-
-
ACI
ACI B5C-CO-1000P-O-X : Carbon Monoxide Toxic Gas Transmitter, 0-1000 ppm, BACnet MSTP, 3 SPDT Relays, ETL, NEMA 4X
MSRP: $1,506.00Your Price: $730.40 -
ACI
ACI B5C-CO-250P-O-X : Carbon Monoxide Toxic Gas Transmitter, 0-250 ppm, BACnet MSTP, 3 SPDT Relays, ETL, NEMA 4X
MSRP: $1,283.00Your Price: $622.30 -
ACI
ACI CO-D : Carbon Monoxide Sensor, 0-125 PPM Default, (250 PPM Max), Duct Mount, 4-20mA or 2-10VDC Output
MSRP: $1,061.00Your Price: $514.60
Carbon Monoxide
Building automation carbon monoxide sensors can monitor multiple toxic gases in a single mounted unit. These sensors not only detect elevated gas levels but also alert occupants and allow direct control of exhaust fans. Features include network auto-configuration, programmable fan and alarm relays, LED indicators, an integrated display, and an audible alarm, ensuring prompt notification of potential issues. The analog output model adds flexibility with menu-selectable 0-5/10V, 1-5V, and 4-20mA outputs, while dual outputs support cost-effective sensing and control of large areas through daisy chain wiring.
The versatility of the BACnet/Modbus model extends to its support for BACnet MS/TP and Modbus RTU networks, simplifying integration with auto-configuration capabilities that detect network parameters. These sensors offer high reliability, minimizing callbacks, thanks to temperature-compensated elements for maximum accuracy and a UL2034 recognized electrochemical CO sensing element.