null Skip to main content

Belimo 22RTH-5U00D : Room Temperature/Humidity Sensor, Modbus RTU + BACnet MS/TP digital + 1x Digital Input, MP-Bus + Modbus RTU + BACnet MS/TP, ePaper Touch Display + LED, Setpoint Adjustment, White (RAL 9003), 5-Year Warranty

Belimo

MSRP: $763.00
$343.35
(You save $419.65 )
(No reviews yet) Write a Review
SKU:
22RTH-5U00D
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
Measured ValuesRH / Dew Point / Temperature
Output SignalModbus/BACnet
CommunicationBACnet/Modbus
DisplayePaper Touch
SetpointYes
Warranty5 Years

The Belimo 22RTH-5U00D is a wall-mount active room sensor measuring Relative Humidity, Dew Point, and Temperature with native Modbus RTU and BACnet MS/TP communication for direct integration with any modern building automation system, plus an MP-Bus channel for Belimo network applications. The high-contrast ePaper touch display (2.72 x 2.44 inch) provides on-device readout of all measured values and direct setpoint adjustment by the occupant — no smartphone required. The sleek white (RAL 9003) housing matches commercial interior finishes and mounts to a single-gang box or flat to drywall.

Best ForConference rooms, hotel guest rooms, executive offices, and demand-controlled spaces where humidity control matters as much as temperature — dehumidification reset, dew-point control, freeze protection, and occupant comfort all benefit from a combined RH + temperature point.
5-Year WarrantyBacked by Belimo's 5-year warranty against defects in materials and workmanship. UL/cULus listed per UL60730-1, CE marked, IEC/EN 60730-1 compliant, ISO 9001 manufacturing.

Key Features

Native BACnet MS/TP + Modbus RTU

Direct integration with any major BAS — no gateway, no protocol converter. The room sensor exposes all measured values, setpoints, and configuration parameters as standard BACnet objects or Modbus registers. MP-Bus is also available for Belimo damper actuator networks.

ePaper Touch Display

2.72 x 2.44 inch high-contrast ePaper touch screen shows live values for all measured parameters. Occupants tap directly on the display to nudge the temperature setpoint. Optional 4-digit access code blocks unauthorized adjustments.

Capacitive Humidity Sensor

Long-term-stable capacitive RH element with ±2% accuracy between 0-90% RH at 25°C and ±0.25% RH/year drift. Dew point is calculated and provided as an additional measured value.

Configurable Setpoint Range

Define how far the occupant can shift the setpoint above or below the BAS schedule. All limits, scaling, and offsets are configurable via the Belimo Assistant App or BAS object writes — no DIP switches, no jumpers.

Technical Specifications

Specification
Measured ValuesRelative Humidity, Dew Point, Temperature
Output SignalModbus RTU + BACnet MS/TP digital + 1x Digital Input
CommunicationMP-Bus + Modbus RTU + BACnet MS/TP
Temperature Range32...122°F [0...50°C] (default, configurable)
Temperature Accuracy±0.3°C @ 25°C [±0.5°F @ 77°F]
Humidity Range0...100% RH (default, configurable)
Humidity Accuracy±2% between 0...90% RH @ 77°F [25°C]
Humidity Long-Term Stability±0.25% RH per year
Dew Point Range-58...122°F [-50...50°C]
DisplayePaper Touch Display + LED
Setpoint AdjustmentYes (via Display App or ePaper touch)
Nominal VoltageAC/DC 24 V
Voltage Range19.2...28.8 V (AC or DC)
Power Consumption1 VA AC / 0.5 W DC
Electrical ConnectionSpring-loaded terminal 0.25-1.5 mm²
Cable EntryBack, top, and bottom side
HousingPC, white, RAL 9003
ProtectionIP30 / NEMA 1
Ambient Temperature32...122°F [0...50°C]
Ambient HumidityMax 95% RH, non-condensing
Storage Temperature-40...160°F [-40...70°C]
Display Size2.72 x 2.44 in [69 x 62 mm] ePaper touch
CertificationsUL/cULus per UL60730-1, IEC/EN 60730-1, CE, ISO 9001
Warranty5 Years

Documentation

Frequently Asked Questions

What does the 22RTH-5U00D actually measure?

The 22RTH-5U00D measures relative humidity, dew point, temperature (calculated). All values are available simultaneously over mp-bus + modbus rtu + bacnet ms/tp.

Does the BACnet/Modbus version still need analog wiring?

No. The 5U00 series provides all measured values and accepts setpoint writes over Modbus RTU or BACnet MS/TP — only power (24 V) and the digital network conductors are required at the wall sensor. A digital input is also provided on-board for window-open, occupancy, or override contacts.

How does the occupant change the setpoint?

The ePaper touch display shows the current setpoint and accepts touch input directly on the device. An optional 4-digit access code can be enabled to prevent unauthorized changes, and the BAS can constrain how far the setpoint may deviate from the schedule.

What's the power requirement?

AC/DC 24 V nominal (19.2-28.8 V tolerance). Power consumption is 1 VA AC or 0.5 W DC. Use Class 2 supply per UL60730-1; cable type CL2 or higher for USA/Canada installations.

How does this mount?

PC housing in white RAL 9003 mounts directly to a single-gang electrical box (back-side cable entry) or flat to drywall (top or bottom cable entry). Spring-loaded terminals accept 0.25-1.5 mm² conductors — no screws to overtighten.

Sensor Type:
Wall Mount
Temperature Element:
BACnet/Modbus
Supported Protocols:
BACnet/Modbus
Humidity Element:
2%
CO2 Element:
None
Setpoint:
Setpoint
Override:
No Override
Display:
ePaper Display
Material:
Plastic