null Skip to main content

Belimo 22WP-514 : Active Liquid Pressure Sensor, Strain Gauge on Stainless Steel Membrane, 0-50 psi Range, 0-10V Output, 1/4" NPT, Stainless Steel Housing, NEMA 4 / IP65, 24 VAC/VDC, 5-Year Warranty

Belimo

MSRP: $518.00
$233.10
(You save $284.90 )
(No reviews yet) Write a Review
SKU:
22WP-514
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
TypeLiquid Pressure Sensor
Range0–50 psi
Output0–10V
Overpressure100 psi
Burst150 psi
Connection1/4" NPT
HousingStainless Steel
EnclosureNEMA 4 / IP65

The 22WP-514 is a Belimo active 24V pressure sensor for liquids — designed for water, water-glycol mixtures, refrigerants, and other non-aggressive gases in HVAC systems. The sensor covers a Medium (0–50 psi) measuring range with 0-10V active output. The sensing element is a strain gauge on a stainless steel membrane with <±0.5% FS accuracy at 70°F (slightly relaxed across the wider operating temperature envelope) and ±0.1% per year long-term stability. The stainless steel 1.4301 housing with FKM (silicone-free) seal is rated IP65 / NEMA 4 and survives operating ambient from -40 to 221°F. The 1/4" NPT pressure connection threads directly into standard hydronic tappings, and the MVS plug (DIN EN 175301-803 Type A) electrical connector accepts 0.5–1.5 mm¬≤ wire. Burst pressure tolerance is 150 psi — 3× the high end of the measuring range — protecting the sensor from transient overpressure events common in hydronic systems (pump starts, sudden valve closures, water hammer).

Best For

Pressure monitoring on liquid HVAC systems where the working pressure falls in the 0–50 psi range: typical commercial chilled-water and hot-water hydronic systems, primary loop pressure, pump discharge monitoring. For the same pressure range with 4-20 mA output instead (useful for long cable runs or controllers preferring current loops), see 22WP-534. Same output style, other ranges: 22WP-511 (Low (0–15 psi)), 22WP-516 (High (0–100 psi)).

5-YEAR WARRANTY
Backed by Belimo's industry-leading 5-year factory warranty. ZOT Supply is an authorized Belimo distributor with fast nationwide and international shipping — every unit ships factory-tested with full warranty support.

Key Features

Medium (0–50 psi) Pressure Range

Strain gauge on stainless steel membrane sized for the 0–50 psi range — matched to typical commercial HVAC hydronic working pressures with high analog resolution and 3× burst pressure tolerance (150 psi) for water-hammer protection.

Stainless Steel 1.4301 Housing

Welded stainless steel housing with FKM (Viton-class) seal, silicone-free — compatible with refrigerants, hot water, chilled water, and water-glycol mixtures where silicone outgassing would contaminate the medium. IP65 / NEMA 4 rated for wet and washdown environments.

Strain Gauge Sensing Element

<±0.5% FS (Full Scale) accuracy at 70°F (21°C), <±1.5% FS across the 14-122°F operating range, <±2% FS across the full -40 to 221°F range. Long-term stability ±0.1% per year — no field calibration required for the lifetime of the sensor.

150 psi Burst Pressure

Burst pressure tolerance of 150 psi — 3× the high end of the measuring range. Survives transient overpressure events from pump starts, sudden valve closures, and water hammer without sensor damage or calibration drift. Negative overpressure tolerance -1 bar (-14.5 psi) handles vacuum-side transients from pump cavitation events.

Multi-Fluid Compatibility

Rated for water, water-glycol mixtures (any concentration), refrigerants, and non-aggressive gases. Steam inlet acceptable up to 100 kPa (15 psi). FKM seal and stainless steel wetted parts compatible with all common HVAC heat-transfer fluids. Open-loop systems are acceptable (unlike ultrasonic flow sensors which require closed-loop).

1/4" NPT Pressure Connection

Standard 1/4" male NPT thread on the pressure port — installs into any standard hydronic tee or pressure tap without adapters. Use thread sealant (PTFE tape or pipe dope rated for the fluid temperature) on installation.

Low Power Consumption

0.3 VA AC / 0.15 W DC — compatible with standard 24V control transformers shared with actuators and other sensors. AC/DC 24V both supported.

5-Year Belimo Warranty

Industry-leading factory warranty backed by Belimo's worldwide service network.

Technical Specifications

SpecificationDetail
Sensor StyleActive pressure sensor for liquids and non-aggressive gases
Measured ValueRelative pressure (gauge pressure vs atmospheric)
Measuring FluidWater, water-glycol mixtures, refrigerants, steam (‚â§100 kPa / 15 psi inlet), non-aggressive gases
Sensing ElementStrain gauge on stainless steel membrane
Output Signal1× active analog: 0-10 V, min. 5 kΩ load resistance
Pressure Measuring Range0–50 psi
Overpressure Tolerance (Positive)100 psi
Overpressure Tolerance (Negative)-1 bar (-14.5 psi) — handles pump cavitation transients
Burst Pressure150 psi — 3× nominal range
Pressure Accuracy at 70°F<±0.5% FS (Full Scale)
Pressure Accuracy 14–122°F<±1.5% FS
Pressure Accuracy -40–221°F<±2% FS (full operating envelope)
Long-Term Stability±0.1% FS per year
Typical Response Timemax. 2 ms
Power SupplyAC/DC 24V (AC 21.6-26.4V / DC 13.5-26.4V); 0.3 VA AC / 0.15 W DC
Power Consumption0.3 VA AC / 0.15 W DC
Electrical ConnectionMVS plug per DIN EN 175301-803 Type A, accepts 0.5-1.5 mm² wire
Pressure Connection1/4" NPT (external thread)
Housing MaterialStainless steel 1.4301 (304 stainless)
Seal MaterialFKM fluororubber (Viton-class), silicone-free
Enclosure RatingNEMA 4 / IP65 (suitable for wet and washdown environments)
Protection ClassIEC/EN III, PELV (Protective Extra-Low Voltage)
Ambient Temperature-40 to 221°F (-40 to 105°C)
Fluid Temperature-40 to 255°F (-40 to 125°C) — frost protection required below 36°F (2°C)
Ambient HumidityMax. 95% RH, non-condensing
EU ConformityCE Marking
CertificationIEC/EN 60730-1
Quality StandardISO 9001
ManufacturerBelimo
Manufacturer Part Number22WP-514
Warranty5-year factory warranty

What's In the Box

Parts Included
  • 22WP-514 liquid pressure sensor in stainless steel housing with FKM seal
  • MVS plug electrical connector (DIN EN 175301-803 Type A)

Note: thread sealant (PTFE tape or pipe dope rated for the working fluid temperature) is NOT included — use installer-supplied sealant rated for the specific medium and temperature.

Documentation

Frequently Asked Questions

What does the 22WP-514 measure and output?

It measures gauge pressure (pressure relative to atmospheric) of liquids and non-aggressive gases — water, water-glycol mixtures, refrigerants, and steam (up to 15 psi inlet). The pressure range is 0–50 psi, and the output is 0-10V active (voltage signal compatible with most modern BAS controllers).

What is the burst pressure rating?

Burst pressure is 150 psi — 3× the high end of the measuring range. This protects the sensor from transient overpressure events common in hydronic systems: pump starts (water hammer), sudden valve closures, hydrostatic test events during commissioning, and chiller compressor cycling. The sensor will continue to read accurately at 100 psi (overpressure tolerance) — only physical damage occurs above the burst rating. Negative overpressure tolerance is -1 bar (-14.5 psi) to handle pump cavitation transients.

What media can I use this sensor with?

The stainless steel 1.4301 wetted parts and FKM (Viton-class) silicone-free seal are compatible with: water (hot, chilled, condenser), water-glycol mixtures (any concentration), refrigerants (R-410A, R-32, R-134a, R-1234ze, R-1234yf, and others), steam up to 100 kPa (15 psi) inlet pressure, and non-aggressive gases. NOT compatible with: chlorinated brine, ammonia (NH3 — corrodes copper and may damage stainless), aggressive industrial chemicals, or fluids above 255°F.

How is the sensor installed?

Thread the 1/4" NPT male connection into a standard hydronic tap or tee, using PTFE thread sealant or pipe dope rated for the fluid temperature. The MVS plug electrical connector (DIN EN 175301-803 Type A) lands on the back of the sensor housing — wire it with 0.5–1.5 mm¬≤ conductors. Mount in any orientation; the strain gauge is gravity-independent. For installations with significant vibration (near pumps), use a flexible pipe section or pulsation dampener upstream of the sensor.

What is the accuracy at typical HVAC operating temperatures?

Pressure accuracy varies with ambient temperature: <±0.5% FS at 70°F (21°C — the calibration reference), <±1.5% FS across the typical HVAC ambient range of 14-122°F (-10 to 50°C), and <±2% FS across the full operating envelope of -40 to 221°F. For a 50 psi range sensor, that's worst-case ±0.8 psi error in a normal mechanical room, ±1.0 psi at extreme ambient temperatures.

Where can I install this sensor — indoor or outdoor?

Indoor or outdoor — the stainless steel housing with IP65 / NEMA 4 rating handles wet, washdown, and outdoor environments. Operating ambient temperature range is -40 to 221°F. The most common applications are mechanical rooms (boiler/chiller plant), penthouse air-handler rooms, and rooftop hydronic loops. The fluid temperature range (-40 to 255°F) covers all standard HVAC heat-transfer fluids; frost protection is required below 36°F (2°C) on the fluid side to prevent freezing in the sensor cavity.

How is this different from other 22WP variants?

All 22WP variants share the same chassis (stainless steel housing, strain gauge on stainless steel membrane, 1/4" NPT connection, FKM seal). The differences are pressure range and output type. This SKU: 0–50 psi range with 0-10V active output. Same range with the alternate output: 22WP-534. Other ranges with 0-10V active output: 22WP-511 (Low); 22WP-516 (High); 22WP-517 (Very High).

Does it need 24V power?

Yes — 24 VAC or 24 VDC supported (AC 21.6-26.4V / DC 13.5-26.4V). Power consumption 0.3 VA AC / 0.15 W DC — very low draw, suitable for sharing a 24V transformer with multiple sensors and small actuators.

Series:
22WP
Pressure Range Class:
psi Range
Pressure Range:
0-50 psi
Direction:
Unidirectional
Output Signal:
4-20 mA + Voltage
Display:
None
Accuracy Class:
Unspecified
Mounting:
Inline
Probe:
No Probe
Made in USA:
Unspecified