Break Glass Stations
Pilla break glass emergency stations are UL Listed control stations that require the physical breaking of a glass lens or panel to actuate — providing an irreversible, auditable activation record at the point of emergency. Common applications include emergency electrical disconnect, boiler shut-down, chiller stop, generator stop, HVAC shut-down, fuel shut-off, ventilation control, and refrigerant purge across commercial and industrial facilities.
ZOT Supply stocks the full Pilla ST120 break glass line as an authorized distributor — surface-mount and flush-mount configurations across NEMA 1, 3R, 4&12, 4X nonmetallic, and 304 stainless steel enclosures. Most models are available with no push button (auto-release when glass broken), a momentary button behind glass, or a maintained button behind glass. Contact blocks are ordered separately and most stations accept 1–6 stackable contact blocks.
Shop by Series
ST120SN Series
Surface-Mount Break Glass — Multiple NEMA Ratings
›NEMA 1 metallic (SN1) — dry indoor locations
›NEMA 3R (SN3R) — outdoor rain exposure
›NEMA 4&12 (SN4) — indoor/outdoor, dust & splash
›NEMA 4X all-nonmetallic (SN4XNM) — corrosion resistant
›NEMA 4&12 304 stainless steel (SN4XS304)
›Maximum duty model available (SN4MDYSL)
›Fits 1–6 contact blocks • UL Listed
ST120FN Series
Flush-Mount Break Glass — NEMA 1 & NEMA 4&12
›Flush-mount NEMA 1 (FN1) — standard backbox included
›Flush-mount NEMA 4&12 (FN4) — wet location rated
›FWB series — flush-mount NEMA 1 without backbox
›No button, momentary (BP1), or maintained (BP2) behind glass
›Wide range of application-specific legends available
›Fits 1–6 contact blocks • UL Listed
WPSBR Series
Wall Plate Break Glass — Single-Gang Stainless Steel
›Flush single-gang stainless steel plate with hammer & chain
›NEMA 1 (indoor) rated
›Emergency Power Off, Emergency Stop, Shut-Off & custom legends
›Specialty N.O./N.C. contact block (PILKA1BR)
›Replacement lenses (PILKBR) available separately
›Fits standard single-gang electrical box
Operator Options Available Behind Glass
Available legends include: Emergency Electrical Disconnect, Emergency Boiler Shut-Down, Emergency Chiller Stop, Emergency Fuel Shut-Off, Emergency Gas Shut-Off, Emergency Generator Stop, Emergency HVAC Shut-Down, Emergency Power Off, Emergency Refrigeration Stop, Emergency Shut-Down, Emergency Shut-Off, Emergency Stop, Emergency Ventilation On/Start/Stop/Shut-Down, Exhaust Fan, Refrigerant Purge, and custom labels — most available across all enclosure types and operator configurations.