The Dwyer ADPS-08-2-N is a compact, cost-effective adjustable differential pressure switch for HVAC, ventilation, and building-automation applications. It covers a setpoint range of 0.08-1.20 in WC (20-300 Pa), uses a silicone diaphragm and SPDT relay output, and is field-adjusted with a dual-scaled knob (in WC and pascals) that lets a technician set the trip point without a separate manometer. Electrical entry is via M20x1.5 cable gland, and the housing is rated NEMA 13 (IP54) for typical HVAC indoor installation. The ADPS-08-2-N is CE marked for general HVAC use, and is rated for air and other non-combustible, non-aggressive gases only.
WARRANTY
Key Features
Dual-Scale Field-Adjustable Knob
Setpoint is dialed in with a labeled knob graduated in both inches WC and pascals. Technicians can commission the switch without a separate digital manometer, which cuts installation and balancing time on large jobs.
Compact 4.4 oz Form Factor
Switch weighs just 125 grams and mounts directly to wall, sheet metal, or via the optional A-288 L-bracket or A-289 S-bracket. The base also accepts snap-on rail clips, so the same SKU works for permanent installs and quick service replacements.
SPDT Relay for BAS/DDC Integration
Single-pole double-throw relay rated 1.5 A resistive / 0.4 A inductive at 250 VAC. Common, normally-open, and normally-closed contacts are available on push-on screw terminals - drops straight into DDC, BAS, or stand-alone control wiring.
Three-Side Cable Entry
M20x1.5 cable gland with integral strain relief can be installed at any of three housing positions, which lets the installer route cable from whichever side keeps the run cleanest. Seal accepts 7 mm or 10 mm cable sheaths.
Long Mechanical Life
Silicone diaphragm and over 1,000,000 mechanical switching operations rated. The switch is designed for continuous duty in HVAC service with no scheduled maintenance beyond periodic calibration checks.
Cost-Effective HVAC Workhorse
The ADPS family is engineered as a high-volume, low-cost replacement for legacy differential pressure switches in HVAC and BAS service. Same external footprint as competing brands, drop-in compatible on most retrofits.
Technical Specifications
| Specification | Value |
|---|---|
| Model | ADPS-08-2-N |
| Operating Range | 0.08-1.20 in WC (20-300 Pa) |
| Approx. Deadband at Min. Setpoint | 0.04 in WC (10 Pa) |
| Approx. Deadband at Max. Setpoint | 0.05 in WC (12 Pa) |
| Service | Air and non-combustible, compatible gases (not for natural gas or other combustibles) |
| Wetted Materials | Diaphragm: silicone. Housing: POM. Switch body: PA 6.6. Cover: polystyrene. |
| Pressure Limit, Max Operating | 40 in WC (10 kPa) for all ranges |
| Temperature Limits, Process & Ambient | -4 to 185 F (-20 to 85 C) |
| Temperature Limits, Storage | -40 to 185 F (-40 to 85 C) |
| Switch Type | 1 Form C relay, SPDT |
| Electrical Rating | Max 1.5 A resistive / 0.4 A inductive @ 250 VAC, 50/60 Hz |
| Max Switching Rate | 6 cycles/min |
| Electrical Connections | Push-on screw terminals; M20x1.5 cable gland entry |
| Process Connections | 5/16 in (7.94 mm) OD tubing, 1/4 in (6.0 mm) ID tubing |
| Enclosure Rating | NEMA 13, IP54 |
| Mounting Orientation | Vertical, pressure connections pointing downwards |
| Setpoint Adjustment | Dual-scale rotary knob (inches WC + pascals) |
| Mechanical Life | Over 1,000,000 switching operations |
| Weight | 4.4 oz (125 g) |
| Compliance | CE marked (general HVAC use) |
| Manufacturer Part Number | ADPS-08-2-N |
Documentation
Frequently Asked Questions
What pressure range does the ADPS-08-2-N cover?
What does the dual-scale adjustment knob do?
Can the ADPS-08-2-N be used with natural gas or other combustible gases?
What's the difference between ADPS-08-2-N (-2-N) and the -1-N variant?
How is the ADPS different from the EDPS?
How do I plumb the process tubing to this switch?
- Brand:
- Dwyer
- Series:
- ADPS
- Product Type:
- HVAC Differential Pressure Switch
- Operating Range:
- 0.08-1.20 in WC (20-300 Pa)
- Range Code:
- -08
- Deadband at Min Setpoint:
- 0.04 in WC (10 Pa)
- Deadband at Max Setpoint:
- 0.05 in WC (12 Pa)
- Service:
- Air, Noncombustible Gases (not natural gas)
- Switch Type:
- SPDT, 1 Form C Relay
- Electrical Rating:
- Max 1.5 A resistive, 0.4 A inductive at 250 VAC, 50/60 Hz
- Max Switching Rate:
- 6 cycles/min
- Process Connection:
- 5/16 in (7.94 mm) OD tubing
- Electrical Entry:
- M20x1.5 cable gland
- Pressure Limit (Max Operating):
- 40 in WC, 10 kPa
- Temperature Range (Process and Ambient):
- -4 to 185 F, -20 to 85 C
- Temperature Range (Storage):
- -40 to 185 F, -40 to 85 C
- Enclosure Rating:
- NEMA 13, IP54
- Wetted Materials:
- Silicone diaphragm, POM housing, PA 6.6 switch body, polystyrene cover
- Diaphragm Material:
- Silicone
- Mechanical Life:
- Over 1,000,000 switching operations
- Mounting Orientation:
- Vertical, ports down
- Setpoint Adjustment:
- Dual-Scale Rotary Knob (inches WC and Pa)
- Certifications:
- CE (general HVAC use)
- Weight:
- 4.4 oz, 125 g