Senva PW30W-C : Diff Pressure Transmitter, 4-20 mA / 0-5V / 0-10V Output, LCD Display, Plastic NEMA 4X, Conduit (field-wired), Transmitter Only, 12-30 VDC/24 VAC, 7-Year Warranty, Made in USA

Senva

MSRP: $7,151.03
$207.50
(You save $6,943.53 )
(No reviews yet) Write a Review
SKU:
PW30W-C
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
TypeWet-to-Wet Differential Pressure
Range1-500 PSID (sensor-dependent)
Sensor2x PWT Sold Separately
Output4-20 mA, 0-5V, 0-10V
DisplayLCD (High, Low, dP)
EnclosurePlastic NEMA 4X
CableConduit (field-wired)
BypassNone
Power12-30 VDC / 24 VAC
Warranty7-Year Electronics

The Senva PW30W-C is a wet-to-wet differential pressure transmitter using dual remote sensors to eliminate the bypass tubing, snubbers, and isolation valve assemblies that traditional flange-mount dP transmitters require. The remote sensors mount directly to pipe via 1/4 inch MNPT, and a DIN43650 plug-and-play connection eliminates wire twisting between the sensor and the transmitter head. This SKU is the transmitter only; pair with two matching PWT remote sensors (PWT050, PWT100, PWT250, or PWT500, sold separately) - one on each pressure leg - to set the working pressure range.

The transmitter housing is PC/ABS Plastic (NEMA 4X) with an LCD display showing high, low, and differential pressures, and DIP switches for range selection (16 ranges), uni/bi-directional mode, fast/slow response, port swap, and test mode. Output is switch-selectable between 2-wire 4-20 mA loop-powered and 3-wire 0-5V / 0-10V on the same terminal block. Electrical connection on this SKU is Conduit Connection (field-wired). The integrated surge snubber protects the sensor element from water hammer for reliable long-term performance, and manual + remote zero push-button capability maintains accuracy across the service life.

Best For

Wet differential pressure measurement where the working range is determined at install time by choosing the matching PWT remote sensor (PWT050/100/250/500): HVAC pump-speed control and demand measurement; Filter dP and clog detection; Process pressure control on water, glycol, and 316L SS-compatible media; System leak detection; Data center wet-side pressure sensing. The remote-sensor architecture eliminates the cost and labor of bypass plumbing on existing installs.

MADE IN USAManufactured at Senva's Beaverton, OR facility. Qualifies under Buy America Act (49 CFR 661.5(d)), Buy American Act (41 USC 10a), Build America Buy America Act (BABAA), Trade Agreements Act (TAA), and ARRA Section 1605. Domestic-component cost exceeds 65%. Conformance declaration available on request.
Remote Sensors (Sold Separately - Qty 2 Required)
Choose 2x PWT050 / PWT100 / PWT250 / PWT500

This is a transmitter-only SKU. To complete the measurement loop, pair this transmitter with two matching PWT remote sensors (one on each pressure leg) sized for your working pressure: PWT050 (0-50 PSIG), PWT100 (0-100 PSIG), PWT250 (0-250 PSIG), or PWT500 (0-500 PSIG). All PWT sensors are 316L SS with 1/4 inch MNPT process connection and plug into the transmitter via DIN43650 leads.

7-Year ElectronicsSenva 7-year warranty on transmitter electronics; 2-year warranty on replaceable elements (including remote sensors). Manufactured in the USA at Senva's Beaverton, OR facility (transmitter electronics).

Key Features

Remote-Sensor Architecture

Dual sensors mount directly to pipe via 1/4 inch MNPT - no bypass tubing, no needle valves, no snubbers, no plumbing-trade dependency. Faster install, fewer leak points.

16 Selectable Differential Ranges

DIP switches let one device cover 1-500 PSID. Field-changeable without tools or a HART communicator. Re-range for a different application without re-ordering hardware.

LCD: High, Low, and dP

Built-in LCD shows the high-side pressure, low-side pressure, AND the differential. Verification at a glance during balancing or commissioning, no DMM needed.

Output Switch-Selectable

2-wire 4-20 mA loop-powered, 3-wire 0-5V, or 3-wire 0-10V on the same terminal block. DIP switch selects the mode at install time.

Port Swap

DIP switch reverses the high/low channel assignment in firmware, correcting plumbing errors without re-piping. Includes uni/bi-directional mode and absolute mode.

Integrated Surge Snubber

Surge protection on each sensor input shields the strain-gauge element from water hammer, extending service life on pump-controlled and valve-actuated systems.

Manual + Remote Zero

Local push-button zero (5-second hold) and remote zero via terminal-block input. Hold for 10 seconds to restore factory defaults. Maintains accuracy across the service life.

DIN43650 Sensor Connection

Remote sensors come standard with DIN43650 plug-in connection - no wire twisting, no mis-wired polarity, faster swap-out for replacement or pressure-range change.

NEMA 4/IP65 Enclosure

This SKU's housing is PC/ABS Plastic (NEMA 4X). Suitable for indoor and outdoor mechanical-room installation.

Made in USA Electronics

Transmitter electronics manufactured at Senva's Beaverton, OR facility. The transmitter itself (without a PWT remote sensor) qualifies for BABAA, TAA, and Buy America procurement.

Technical Specifications

SpecificationValue
SeriesPW30 Remote Wet-to-Wet Differential Pressure Transmitter
Sensor TypeMicro-machined silicon strain gauge
Pressure Range16 DIP-selectable, 1-500 PSID (sensor dependent)
Output Signal2-wire 4-20 mA (loop-powered), 3-wire 0-5V, 3-wire 0-10V (switch-selectable)
Accuracy+/-1% typ, +/-2% on lowest sub-range
Sensor Performance Accuracy<+/-0.25% BFSL
Stability (1 year)+/-0.25% FS typical
Over-range Protection200% rated pressure
Pressure Cycles> 100 million
Compensated Operating Range14 to 158 degF (-10 to 70 degC)
Operating Temperature (Transmitter)-22 to 158 degF (-30 to 70 degC)
Operating Humidity0 to 90% RH non-condensing
Media Temperature32 to 250 degF (0-125 degC); siphon tube required for steam
Media CompatibilityWater and other 316L SS-compatible media
Vibration10G peak, 20 to 2000 Hz
Power Supply (0-5V mode)12-30 VDC / 24 VAC, 20 mA max
Power Supply (0-10V mode)13-30 VDC / 24 VAC required for 10V FS output
Power Supply (4-20 mA mode)15-30 VDC (0 Ohm) / 16-30 VDC (250 Ohm) / 18-30 VDC (500 Ohm), 20 mA max
Power Consumption5 W max
Zero AdjustmentAutomatic, push-button (5 sec re-zero, 10 sec factory restore), remote zero input
DIP Switch FunctionsRange, test mode, uni/bi-directional, slow/fast response, port swap, absolute mode
Transmitter EnclosurePC/ABS Plastic (NEMA 4X)
Transmitter Enclosure RatingNEMA 4X / IP65
Electrical ConnectionConduit Connection (field-wired)
Bypass ManifoldNone (optional service valve PWBV sold separately)
Remote SensorSold Separately (transmitter only - requires 2 PWT sensors)
Sensor Construction316L SS, 1/4 inch MNPT process, 1/2 inch conduit fitting
Sensor Connection to TransmitterDIN43650 plug-and-play lead
ApprovalsCE, RoHS, ISO
Country of Origin (Transmitter)Made in USA - Beaverton, OR
Country of Origin (PWT Remote Sensor)N/A (sold separately)
Warranty (Electronics)7 Years
Warranty (Replaceable Elements)2 Years
Manufacturer Part NumberPW30W-C

Selectable Differential Pressure Ranges

Remote Sensor2% Accuracy Ranges1% Accuracy Ranges
PWT050 (0-50 PSIG)0-10 / 0-15 PSID0-20 / 0-25 / 0-30 / 0-40 / 0-50 PSID
PWT100 (0-100 PSIG)0-15 / 0-20 / 0-25 / 0-30 PSID0-40 / 0-50 / 0-75 / 0-100 PSID
PWT250 (0-250 PSIG)0-30 / 0-40 / 0-50 PSID0-75 / 0-100 / 0-125 / 0-150 / 0-250 PSID
PWT500 (0-500 PSIG)0-75 / 0-100 / 0-125 PSID0-150 / 0-250 / 0-500 PSID

Note: Senva recommends not using an output range less than 10% of the sensor's total PSIG due to lower accuracy at the extreme low end. FS is defined as the full scale of the selected sub-range, including non-linearity, hysteresis, and repeatability.

Documentation

Frequently Asked Questions

Does the PW30W-C include remote sensors?

No. This is a transmitter-only SKU. You need to pair it with two PWT remote sensors (one per pressure leg) - sold separately: PWT050 (0-50 PSIG), PWT100 (0-100 PSIG), PWT250 (0-250 PSIG), or PWT500 (0-500 PSIG). Choose the sensor pair that comfortably covers your system's maximum static pressure - your differential reading then uses a sub-range selected by DIP switch on the transmitter.

Why would I buy the transmitter without sensors?

Two common reasons: (1) you have existing PWT sensors on the pipe from a previous install and only need to replace the transmitter head; (2) you're standardizing on a field-stocked single transmitter SKU and want to pick the PWT sensor size at install time based on field conditions. Also, the transmitter-only SKUs qualify for Buy America / BABAA / TAA; the PWT sensors do not.

What enclosure does the PW30W-C use?

The transmitter housing on this SKU is PC/ABS Plastic (NEMA 4X). The plastic enclosure is rated NEMA 4X / IP65, corrosion-resistant, and well-suited to washdown, cooling-tower, and outdoor applications.

How do I wire this transmitter?

This is a conduit-connection SKU - field-supply your own cable through the conduit fitting and terminate at the screw terminals inside the housing. Use 18-22 AWG shielded twisted-pair for analog signals; ground the shield at the controller end only.

What media can the PW30 measure?

Water and any liquid compatible with 316L stainless steel (316L is the wetted material of the PWT diaphragm). Glycols, treated condensate, and most HVAC hydronic fluids are compatible. Steam applications require a siphon tube to keep the sensor below its 250 degF media temperature limit.

How do I switch between 4-20 mA, 0-5V, and 0-10V output?

A DIP switch on the transmitter board selects the output mode. The same terminal block is used for all three; the difference is the wiring topology (2-wire loop-powered for 4-20 mA, 3-wire for voltage). The transmitter ships configured for 4-20 mA from the factory unless ordered otherwise.

How do I zero the transmitter after installation?

Pressurize both sensor ports equally (or use the bypass manifold if equipped) so the differential is true zero. Then press and hold the local zero button for 5 seconds - the LCD will indicate zero. To restore factory defaults, hold the button for 10 seconds. A remote zero input is also wired to the terminal block for panel-mounted or BAS-triggered re-zero.

Is this transmitter approved for hazardous locations?

No. The PW30 is a standard (non-hazardous) location transmitter. For Class I Division 1 or 2 areas, use the Dwyer / Omega 3100D explosion-proof DP transmitter family instead.

Does this SKU qualify for Buy America / federal procurement?

Yes. The PW30W-C transmitter is manufactured at Senva's Beaverton, OR facility and is listed in Senva's BABAA / TAA / ARRA Conformance Declaration (dated 04/21/2026) as a USA-manufactured product with domestic-component cost exceeding 65%. It qualifies under Buy America Act (49 CFR 661.5(d)), Buy American Act (41 USC 10a), BABAA, TAA, and ARRA Section 1605. Note: if you add PWT remote sensors to this transmitter (two are required for a differential measurement), those sensors are imported and are NOT covered by the declaration.

Brand:
Senva
Series:
PW30W
Pressure Range Category:
Multi-Range (sensor-defined, 1-500 PSID)
Output Signal:
4-20 mA, 0-5V, 0-10V
Hazardous Location:
Standard
Display:
LCD Display
Enclosure:
Plastic (NEMA 4X)
Bypass Manifold:
None
Cable Type:
Conduit Connection
Power Supply:
12-30 VDC / 24 VAC
Wetted Material:
316L Stainless Steel
Country of Origin:
Made in USA