null Skip to main content

Senva PW30W-C : Wet-to-Wet Differential Pressure Transmitter, Plastic NEMA 4X Enclosure, Conduit Connection, Sensors Sold Separately, V/mA Output, LCD, Made in USA

Senva

MSRP: $7,151.03
$207.50
(You save $6,943.53 )
(No reviews yet) Write a Review
SKU:
PW30W-C
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
TypeWet-to-Wet Differential Pressure Transmitter
EnclosurePlastic NEMA 4X
Output Signal4-20 mA / 0-5V / 0-10V
Output SelectionSwitch-Selectable
Pressure Range1 to 500 PSID (16 selectable)
Cable ConnectionConduit
Remote SensorNot Included
Bypass ManifoldNone
DisplayLCD (High / Low / Diff)
Country of OriginMade in USA

The Senva PW30W-C is a wet-to-wet differential pressure transmitter using dual remote PWT sensors at the high and low ports - one of the few wet/wet differential transmitters on the market that eliminates the traditional bypass-plumbing requirement by sensing differential digitally across two independently-mounted absolute sensors. The transmitter is housed in a PC/ABS (Plastic), NEMA 4X / IP65 enclosure with Conduit Connection (1/2 inch fitting, customer-supplied cable). Sensors connect to the transmitter via DIN43650 quick-disconnect - no wire twisting, no plumbing.

The PW30 outputs the standard PW30 selectable output: 2-wire 4-20 mA loop, 3-wire 0-5 VDC, or 3-wire 0-10 VDC (one DIP switch on the main board picks the mode). The on-board LCD shows the high port pressure, low port pressure, and computed differential pressure simultaneously - a meaningful step up from single-output diff-pressure transmitters where you can't see the absolute readings the BAS depends on. Remote sensors are NOT included with this SKU - order one or two PWT-series sensors (PWT050 / PWT100 / PWT250 / PWT500) separately based on the working pressure of the system. The PW30 transmitter pairs with any combination of PWT sensors and supports up to 16 selectable differential ranges from 1 to 500 PSID without re-ordering. Made in USA by Senva Inc. of Beaverton, Oregon.

Best For

Field-configurable installs where the wiring trade pulls customer-supplied cable through conduit, and the controls engineer specs the PWT sensor PSI rating later based on the as-built pressure of each loop. Order the matching PWT050 / PWT100 / PWT250 / PWT500 separately - one or two per transmitter depending on whether differential or absolute measurement is needed.

MADE IN USA - BABAA COMPLIANTDesigned and manufactured by Senva Inc., Beaverton, Oregon. Listed on Senva's Buy America / BABAA / ARRA / TAA conformance statement for Wet Pressure products (PW30 versions without PWT transducers). RoHS and CE compliant.
Senva WarrantySenva 7-year limited warranty on the transmitter electronics. 2-year limited warranty on the PWT replaceable sensor element. RoHS and CE compliant.

Key Features

16 Selectable Differential Ranges (1-500 PSID)

One transmitter spans 1 PSID up to 500 PSID via DIP-switch range selection with the matching PWT sensor PSIG. Reduces SKU count on stocking shelves and lets controls engineers commission unknown-pressure loops without re-ordering a different transmitter mid-job.

Switch-Selectable Output: 4-20 mA / 0-5V / 0-10V

Single DIP switch picks the output mode: 2-wire 4-20 mA loop-powered (15-30 VDC, 250 Ohm max), 3-wire 0-5 VDC (12-30 VDC or 24 VAC), or 3-wire 0-10 VDC (13-30 VDC or 24 VAC). 20 mA max. consumption.

LCD Display: High, Low, & Differential

Built-in LCD shows the high-port pressure, low-port pressure, and computed differential pressure simultaneously - meaningful upgrade over single-output diff-pressure transmitters that hide the absolute readings from the field tech.

Enclosure: Plastic NEMA 4X / IP65

PC/ABS plastic housing rated NEMA 4X / IP65 - washdown-rated, corrosion-resistant, and stable in chemically aggressive environments like cooling-tower decks and chiller plants where chlorinated water mist is unavoidable.

Conduit Connection (1/2 inch)

Customer-supplied cable through a 1/2 inch conduit fitting. Use for long cable runs over 100 ft where pre-fabricated cable doesn't make sense, or for installations following local electrical codes that require conduit on all signal cabling.

Micro-Machined Silicon Strain Gauge

Each PWT sensor uses a micro-machined silicon strain-gauge transducer behind a 316L stainless steel diaphragm. Long-term stability: +/-0.25% FS per year. Pressure cycles: >100 million. Over-range protection: 200% rated pressure.

Sensor-Side Configuration Features

On-board DIP switches handle: range selection (16 differentials), uni/bi-directional mode, slow or fast response filtering, port swap (corrects field-wiring mistakes without re-plumbing), absolute mode, and test-mode output forcing for BAS commissioning.

Push-Button Zero & Span

Pushbutton zero re-zeros the transmitter in 5 seconds. Hold for 10 seconds to restore factory settings. Remote-zero terminal block input allows BAS-initiated re-zero on a schedule.

Surge Snubber Built-In

Integrated surge snubber protects the sensor from water-hammer transients - common cause of premature diff-pressure-sensor failure on pump-cycling loops. Adds significant service life on hydronic systems with variable-speed pumps.

Made in USA - Senva Inc., Beaverton, OR

Designed and manufactured by Senva Inc. in Beaverton, Oregon. RoHS and CE compliant. 7-year warranty on transmitter electronics, 2-year on the replaceable PWT sensor element.

Technical Specifications

SpecificationValue
ManufacturerSenva Inc.
Manufacturer Part NumberPW30W-C
SeriesPW30P (PW30 Wet-to-Wet Differential Pressure)
Sensor TypeWet-to-Wet Differential (Dual Remote Strain-Gauge Sensors)
Sensing ElementMicro-Machined Silicon Strain Gauge (316L SS Diaphragm)
Differential Ranges16 selectable from 1 to 500 PSID (DIP-switch)
Output Signal (Switch-Selectable)2-wire 4-20 mA, 3-wire 0-5 VDC, or 3-wire 0-10 VDC
Power Supply (Voltage Mode)12-30 VDC or 24 VAC, 20 mA max
Power Supply (4-20 mA Mode)15-30 VDC (0 Ohm load) up to 18-30 VDC (500 Ohm), 20 mA max
Sensor Accuracy<+/-0.25% BFSL (sensor element)
System Accuracy+/-1% FS on 1%-class ranges; +/-2% FS on 2%-class ranges (see PW Accuracy Table)
Long-Term Stability+/-0.25% FS per year
Over-Range Protection200% of rated sensor pressure
Pressure Cycles>100 million
Transmitter Operating Temperature-22 to 158 degF (-30 to 70 degC)
Media CompatibilityWater, other 316 SS-compatible liquids
Media Temperature32 to 250 degF (0 to 125 degC); steam requires siphon tube
Operating Humidity0 to 90% RH, non-condensing
Compensated Operating Range14 to 158 degF (-10 to 70 degC)
Vibration Rating10G peak, 20 to 2000 Hz
Zero AdjustmentPushbutton (5s = re-zero, 10s = factory restore) + remote zero input
ConfigurationDIP switches: range, test mode, uni/bi-directional, slow/fast response, port swap, absolute mode
DisplayLCD - shows high port, low port, and differential pressure
EnclosurePC/ABS (Plastic), NEMA 4X / IP65
Cable ConnectionConduit Connection (1/2 inch fitting, customer-supplied cable)
Remote SensorSensors Sold Separately (PWT series)
Sensor-to-Transmitter ConnectionDIN43650 Form-A Quick-Disconnect
Process Connection (PWT Sensor)1/4 inch MNPT
PWT Conduit Fitting1/2 inch
Sensor Body Material304 Stainless Steel
Sensor Wetted Material316L Stainless Steel Diaphragm
Mounting OrientationUnrestricted
Warranty7 years on transmitter electronics; 2 years on PWT replaceable element
Agency ComplianceCE, RoHS
Country of OriginMade in USA - Senva Inc., Beaverton, Oregon

Documentation

Required Sensors (Sold Separately)

This transmitter ships without sensors. Order 1 or 2 PWT remote sensors to complete the wet-to-wet differential install. Match the sensor PSIG rating to the working pressure of the system:

Remote Sensor
Senva PWT050 - 50 PSIG Rating

Use for working differential pressures up to 50 PSID. 1/4 inch MNPT, 316L SS diaphragm, DIN43650 plug-and-play.

View PWT050 »
Remote Sensor
Senva PWT100 - 100 PSIG Rating

Use for working differential pressures up to 100 PSID. 1/4 inch MNPT, 316L SS diaphragm, DIN43650 plug-and-play.

View PWT100 »
Remote Sensor
Senva PWT250 - 250 PSIG Rating

Use for working differential pressures up to 250 PSID. 1/4 inch MNPT, 316L SS diaphragm, DIN43650 plug-and-play.

View PWT250 »
Remote Sensor
Senva PWT500 - 500 PSIG Rating

Use for working differential pressures up to 500 PSID. 1/4 inch MNPT, 316L SS diaphragm, DIN43650 plug-and-play.

View PWT500 »

Frequently Asked Questions

What ranges does this transmitter cover?

16 selectable differential ranges from 1 PSID to 500 PSID, set via on-board DIP switches. The actual accuracy class (1% or 2%) depends on the PWT sensor PSIG rating selected for the install - see the PW Transmitter Accuracy table on the datasheet for the exact range/accuracy mapping per sensor.

Do I need to plumb a bypass loop for this differential transmitter?

No - that's the entire design intent of the PW30 series. Two remote PWT sensors mount directly to the high and low ports of the process pipe via 1/4 inch MNPT, and the transmitter computes differential pressure digitally. No bypass tee, no isolation valves required (manifold versions are still available for legacy process conventions).

How is the analog output configured?

One DIP switch on the transmitter board picks between 2-wire 4-20 mA loop, 3-wire 0-5 VDC, or 3-wire 0-10 VDC. Voltage modes accept 12-30 VDC or 24 VAC supply (13-30 VDC required for 10V FS). Current mode is loop-powered with 15-30 VDC at 0 Ohm load, up to 18-30 VDC at 500 Ohm.

What is the difference between PW30M and PW30W?

PW30M uses a powder-coated steel enclosure rated NEMA 3R / IP65 - outdoor and drip-proof. PW30W uses PC/ABS plastic rated NEMA 4X / IP65 - washdown-rated and corrosion-resistant for chlorinated / chemical environments like cooling-tower decks. Identical internals and identical specs otherwise.

Which PWT sensor do I order with this transmitter?

Match the PWT PSIG rating to the working pressure of your system. Common choices: PWT050 for small hydronic loops (under 50 PSID), PWT100 for typical pump-curve / filter monitoring, PWT250 for high-pressure chiller plant loops, PWT500 for fire-pump or industrial-process applications. Order two sensors for full differential, or one for absolute.

Can I retrofit a PW30 onto an existing single-sensor application?

Yes - configure the transmitter in absolute mode and use a single PWT sensor on the high port. The LCD will show the absolute pressure on the active port and zero on the unused port; the differential reading equals the absolute reading. Useful when an existing 4-20 mA pressure input on the BAS needs a more accurate replacement sensor with no other infrastructure changes.

What is the warranty?

7 years on the transmitter electronics. 2 years on the replaceable PWT sensor element. The split warranty reflects the design philosophy - electronics never wear, but the sensor diaphragm sees full process exposure and is the field-replaceable component.

Where is this product made?

Designed and manufactured by Senva Inc. in Beaverton, Oregon, USA. RoHS and CE compliant.

Brand:
Senva
Series:
PW30W (Plastic NEMA 4X)
Product Role:
Wet-to-Wet Differential Pressure Transmitter
Enclosure:
Plastic NEMA 4X / IP65 (PC/ABS)
Output Signal:
Switch-Selectable: 4-20 mA / 0-5V / 0-10V
Cable Connection:
Conduit Connection (1/2 inch fitting)
Bypass Manifold:
None
Sensor PSIG:
Sensors Sold Separately (PWT050 / PWT100 / PWT250 / PWT500)
Pressure Range:
1 to 500 PSID (16 selectable ranges via DIP switch)
Display:
LCD (High / Low / Differential simultaneous)
Sensor Wetted Material:
316L Stainless Steel Diaphragm
Country of Origin:
Made in USA - BABAA / ARRA / TAA Compliant (Senva conformance list)