Skip to main content

ACI A/AN-DO-8"-6'CL2P : Duct Temperature Sensor, 10K Type III Thermistor, 8" Probe Length, 6 ft (1.83m), 2 Conductor Plenum Rated Cable, Flange Mount

ACI

MSRP: $47.00
$16.76
(You save $30.24 )
(No reviews yet) Write a Review
SKU:
A/AN-DO-8"-6'CL2P
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

ACI A/AN-DO-8"-6'CL2P : Duct Temperature Sensor, 10K Type III Thermistor, 8" Probe Length, 6 ft (1.83m), 2 Conductor Plenum Rated Cable, Flange Mount

ACI duct-mounted thermistors, crafted with rugged stainless steel probes and double-encapsulated for superior moisture resistance, deliver accurate air temperature readings in even the tightest spaces. High-quality thermal epoxy ensures fast response times, while the included insulation pad dampens vibration and seals your duct seamlessly. Choose the perfect sensor length to reach your duct's center (width or diameter) and monitor supply, discharge, return, and mixed air temperatures with ease. Ideal for roof-top units and air handlers, ACI Thermistor Duct Sensors are the key to optimal airflow control and system performance.

Key Features:

  • Double encapsulation: ACI's unique double encapsulation process protects the sensor from moisture and ensures fast response times.
  • Accurate and reliable: These thermistors offer exceptional accuracy (±0.2°C) and a quick response time (10 seconds).
  • Wide range of applications: Suitable for monitoring air temperatures in roof top units, air handlers, and supply,discharge, return, and mixed air ducts.
 

Specifications:

Sensor Type | Sensor Curve: Thermistor | Non-Linear, NTC (Negative Temperature Coefficient)
Number Sensing Points | Number Wires: One | Two (Non-Polarity Sensitive)
Sensor Output @ 25°C (77°F) | (Lead Wire Colors): A/AN (Type III): 10KΩ nominal | (White/White)
Sensor Accuracy 0-70°C (32-158°F): +/-0.2°C (+/-0.36°F)
Response Time (63% Step Change): 10 Seconds nominal
Sensor Operating Temperature Range: -40°C (-40°F) to 150°C (302°F)
Operating Humidity Range: 10 to 95% RH, non-condensing
Probe Material | Probe Diameter: 304 Stainless Steel | 0.250” (6.35mm)
Fitting Material | Flammability Rating: Polyamide 66 (High Performance Nylon) | UL94-HB
Foam Pad Material | Flammability Rating: Neoprene/EPDM/SBR Polymer | UL94-HBF; FMVSS-302; MIL-R-6130C
Conductor Size: 22 AWG (0.65 mm)
Agency Approvals: CE, RoHS2, WEEE

 

Data Sheets

pdf logo Technical Data Sheet – ACI Duct No Box Thermistor Temperature Sensor
pdf logo Instruction – ACI Duct Thermistor Temperature Sensor

 

Sensor Type:
Duct
Temperature Element:
10K Type III
Probe Length:
8
Enclosure:
No Box / Flange
Lead Length:
6 ft Plenum Rated Cable
Supported Protocols:
None
Humidity Element:
None
CO2 Element:
None
Setpoint:
No Setpoint
Override:
No
Display:
No Display