ACI A/RH1-TT1K-D-4X-4 : Duct Relative Humidity Sensor, 1% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 1K Ohms Temperature Transmitter (4 to 20 mA), NEMA 3R Duct Enclosure, Made in USA

ACI

MSRP: $861.00
$327.32
(You save $533.68 )
(No reviews yet) Write a Review
SKU:
A/RH1-TT1K-D-4X-4
Condition:
New
Availability:
Ships in 2-4 Days
Adding to cart… The item has been added

ACI A/RH1-TT1K-D-4X-4 : Duct Relative Humidity Sensor, 1% Accuracy, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 1K Ohms Temperature Transmitter (4 to 20 mA), NEMA 3R Duct Enclosure, Made in USA

The ACI Relative Humidity with Temperature Transmitter Duct Series is a versatile device used in various applications to measure relative humidity and temperature. It incorporates a thermoset polymer capacitive sensing element, which is resistant to moisture and is equipped with a hydrophobic filter to further enhance its moisture resistance. The multilayer construction of the sensing element ensures excellent resistance to dust, dirt, oils, and common environmental chemicals typically encountered in different environments.

The RH duct sensors come with on-board DIP switches that provide user-configurable options for selecting the desired output signal. Additionally, these sensors can be powered by both AC and DC power sources, allowing for greater flexibility in installation.

Calibration of the RH duct sensors can be easily performed in the field. By using the increment and decrement calibration DIP switches, the user can adjust the calibration curve in +/- 0.5% increments with each toggle of the corresponding switches. This feature enables precise calibration without the need to replace the sensors. The ACI RH duct sensors find applications in various settings such as humidification and dehumidification systems, supply and return RH sensing, economizers, clean rooms, data centers, and process control.

Specifications

RH Supply Voltage (Reverse Polarity Protected):

4-20 mA: 250 Ohm Load: 15 - 40 VDC / 18 - 28 VAC | 500 Ohm Load: 18 - 40 VDC / 18 - 28 VAC

0-5 VDC: 12 - 40 VDC / 18 - 28 VAC | 0-10 VDC: 18 - 40 VDC / 18 - 28 VAC

RH Output Signal: 2-wire: 4 - 20 mA (Factory Default) | 3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable)
RH Measurement Range: 0-100%
Operating RH Range: 0 to 95% RH, non-condensing
RH Stability | Repeatability | Sensitivity: Less than 2% drift / 5 years | 0.5% RH | 0.1% RH

 

Datasheets

pdf logo ACI Duct Relative Humidity Temperature Transmitter Data Sheet
pdf logo ACI Duct Relative Humidity Temperature Transmitter Install Sheet

 

Sensor Type:
Duct
Humidity Element:
1%
Output Signal:
4-20mA, 0-5 VDC, or 0-10 VDC
Temperature Element:
Transmitter
CO2 Element:
None
Display:
No Display
VOC Element:
None
Probe Length:
8
Enclosure:
NEMA 4X Enclosure
Supported Protocols:
None