Skip to main content

ACI A/RH2-TT1K-R2-2 : Room Air Relative Humidity Sensor, 2% Accuracy, RH Outputs: 0-5 VDC or 0-10 VDC, 1K Ohms Temperature Transmitter (2 to 10 VDC), Room (R2) Aries Enclosure (White), Made in USA

ACI

MSRP: $505.00
$191.98
(You save $313.02 )
(No reviews yet) Write a Review
SKU:
A/RH2-TT1K-R2-2
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

ACI A/RH2-TT1K-R2-2 : Room Air Relative Humidity Sensor, 2% Accuracy, RH Outputs: 0-5 VDC or 0-10 VDC, 1K Ohms Temperature Transmitter (2 to 10 VDC), Room (R2) Aries Enclosure (White), Made in USA

The ACI Relative Humidity with Temperature Transmitter Room Series utilizes a thermoset polymer capacitive sensing element with a factory applied hygroscopic filter to deliver a proportional analog current or voltage output signal. The hygroscopic filter provides added resistance to moisture, dust, and other chemicals for greater long term reliability. The RH Room transmitter features integral DIP switches for field selection of the proper output signal and supply voltage to meet your applications requirements. Each unit also contains 0%, 50%, and 100% test options to verify that the transmitter is both working and wired properly. Field calibration can be performed by using the increment and decrement calibration DIP switches without the need to replace the sensing element. These enhancements provide increased flexibility and outstanding long-term reliability. The temperature transmitter must be powered with 13.5 to 24 VDC power source and can be ordered as either a two-
wire 4-20 mA or 3-wire voltage output sensor. The temperature transmitter is installed on the back of the enclosure and must be mounted over a single gang junction box in the wall. There are two styling options in this series which should satisfy most commercial decors. Both styles feature four-way airflow to minimize self-heating.

Specifications

RH Supply Voltage (Reverse Polarity Protected):

4-20 mA: 250 Ohm Load: 15 - 40 VDC / 18 - 28 VAC | 500 Ohm Load: 18 - 40 VDC / 18 - 28 VAC

0-5 VDC: 12 - 40 VDC / 18 - 28 VAC | 0-10 VDC: 18 - 40 VDC / 18 - 28 VAC

RH Output Signal: 2-wire: 4 - 20 mA (Factory Default) | 3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable)
RH Measurement Range: 0-100%
Operating RH Range: 0 to 95% RH, non-condensing
RH Stability | Repeatability | Sensitivity: Less than 2% drift / 5 years | 0.5% RH | 0.1% RH

 

Datasheets

Sensor Type:
Wall Mount
Humidity Element:
2%
Humidity Ouput:
0-5 VDC, or 0-10 VDC
Temperature Element:
Transmitter
CO2 Element:
None
Display:
No Display
Supported Protocols:
None
Setpoint:
No Setpoint
Override:
No Override
Material:
Plastic