Skip to main content

ACI PXP7.3 : Analog Input (0-5VDC), Pressure Output (0-15PSI), Single Valve, 0.007" Bleed Orifice, (0-10V, 0-15V, 0-20mA Selectable)

ACI

MSRP: $246.00
$112.87
(You save $133.13 )
(No reviews yet) Write a Review
SKU:
PXP7.3
Condition:
New
Availability:
Ships in 2 Days
Adding to cart… The item has been added

ACI PXP7.3 : Analog Input (0-5VDC), Pressure Output (0-15PSI), Single Valve, 0.007" Bleed Orifice, (0-10V, 0-15V, 0-20mA Selectable)

The PXP*.3 is an electric-to-pneumatic transducer that converts an analog electrical input signal into a proportional pneumatic output. It automatically adjusts its control valve(s) to maintain the branch line pressure at a selected set point determined by the input signal. The PXP*.3 offers four selectable input ranges, resulting in a 0 to 15 psig modulating output (note that the EPC product provides 0 to 20 psig outputs). It also provides a 0-5 VDC feedback signal that corresponds linearly to the branch pressure (0 volts = 0 psig, 5 volts = 15 psig).

PXP1.3, 5.3, and 7.3 are constant bleed controllers, and their branch exhaust response time depends on the bleed orifice size and pressure differentials. In case of a power failure, they continue to release air through the bleed orifice until branch pressure reaches zero psig. A three-way solenoid valve assembly can be used to revert control to the local controller in case of power failure.

Specifications

Supply Voltage: 24 VAC (+/-10%), 50 or 60Hz, 24 VDC (+10%/- 5%)
Supply Current: 160 mA maximum, 200 mA on fail safe models
Input Signal Source (@ Impedance): 0-5 VDC @ 10,000 Ω | 0-10 VDC @ 10,000Ω | 0-15 VDC @ 10,000Ω | 0-20 mA @ 250Ω
Feedback Signal Output Range: 0-5 VDC = Output Span
Output Pressure Range: Field Calibration Possible: 0 to 15 psig (0-103.421 kPa) maximum
Air Supply Pressure: Maximum: 25 psig (172.369 kPa) | Minimum: 18 psig (124.106 kPa)
Air Consumption: See Ordering Grid
Output Pressure Accuracy: 1% full scale @ room temperature | 2% full scale across operating temperature range
Manual / Auto Override: MAN function = output can be varied | AUTO function = output is controlled from input signal
Air Flow: Supply valves @ 20 psig (138 kPa) main/15 psig (103 kPa) out, 750 scim (1400 on LG model) Branch Line requires 2 in3 or 33.78 cm3 (min.). Branch line min. of 25 feet of 1/4” O.D. poly tubing
Filtering: Furnished with integral-in-barb 80-100 micron filter (Part # PN004) except for PXP2LG which is furnished with external 5 micron in-line filter (PN021)
Connections: 90° Pluggable Screw Terminal Blocks
Wire Size: 16 (1.31 mm2) to 26 AWG (0.129 mm2)
Terminal Block Torque Rating: 0.5 Nm (Minimum); 0.6 Nm (Maximum)
Connections | Pneumatic Tubing Size-Type: 1/4" O.D. nominal (1/8” I.D.) polyethylene
Pneumatic Fitting: Removeable brass barbed fittings for Main and Branch in machined aluminum manifold Plugged 1/8-27-FNPT gauge port | Gauge installed at additional cost
Gauge Pressure Range (Gauge Models): 0-30 psig (0-200 kPa)
Gauge Pressure Accuracy (Gauge Models): ± 2.5% Midscale (± 3.5% Full Scale)
Operating Temperature Range: 35 to 120°F (1.7 to 48.9°C)
Operating Humidity Rage: 10 to 95% non-condensing
Storage Temperature: -20 to 150°F (-28.9 to 65.5°C)
Snaptrack Material: Polyvinyl Chloride (PVC)
Snaptrack Flammability Rating: UL94 V-0
Product Dimensions: No Gauge: (L) 3.25” (W) 2.18” (H) 1.87” (82.55 x 55.37 x 47.49 mm)
With Gauge: (L) 3.25” (W) 2.18” (H) 2.95” (82.55 x 55.37 x 74.9 mm)
Product Weight:
PXP1.3: 0.40 lbs. (0.1814 Kg) | PXP2.3: 0.47 lbs. (0.2126 Kg) | PXP1.3G: 0.49 lbs. (0.2211 Kg) PXP2.3G & PXP2.3GFS: 0.59 lbs. (0.2693 Kg)
Agency Approvals: RoHS2, WEEE

 

Data Sheets

Input Signal:
Analog
Output Signal:
Pressure
Guage:
No Gauge
Failsafe:
No Failsafe
Valves:
1 Valve