BAPI BA/DOM-BLE-EZ : Wireless BACnet MS/TP and Modbus RTU Output Module, RS-485, Up to 28 Sensors

BAPI

MSRP: $285.00
$127.68
(You save $157.32 )
(No reviews yet) Write a Review
SKU:
BA/DOM-BLE-EZ
Condition:
New
Availability:
Ships 3-5 days
Adding to cart… The item has been added
Part Number
BA/DOM-BLE-EZ
 
Protocol
BACnet MS/TP or Modbus RTU
 
Sensors
Up to 28
 
Physical Layer
RS-485
 
Config
USB-C
 
Warranty
5 Years

The BAPI BACnet MS/TP and Modbus RTU Output Module (BA/DOM-BLE-EZ) converts data from up to 28 BAPI BLE wireless sensors for integration into RS-485 field networks. The output protocol is field-selectable using the free BAPI Device Configuration utility — one module covers both BACnet MS/TP and Modbus RTU without stocking separate part numbers.

Best for: BAS integrators integrating BAPI BLE wireless sensors into RS-485 field bus networks. Field-selectable protocol is ideal for contractors working across multiple controller platforms where either BACnet MS/TP or Modbus RTU may be required.

5-Year Warranty

Carries BAPI's 5-year warranty. Configuration connects via USB-C and does not require external power to the module — the USB cable provides necessary power during setup.

One Module, Two Protocols — Field Selectable

Download the BAPI Device Configuration utility from bapihvac.com. Connect a USB-C cable (no external power needed). Select BACnet MS/TP or Modbus RTU, configure baud rate and device address, and click Restart. In Modbus mode, the utility generates a downloadable Excel Modbus map with all register addresses for controller programming.

Field-Selectable Protocol

One device covers BACnet MS/TP and Modbus RTU. Select protocol at configuration time using the free BAPI Device Configuration utility. No need to stock separate variants.

USB-C Config — No External Power Needed

The USB-C port powers the module from the computer during setup. No panel power required to configure protocol, baud rate, device address, or object names.

Auto-Discovery of Sensors

Auto-discovers all sensors paired to the receiver. Objects populate after the module receives at least one transmission from each sensor.

Downloadable Modbus Map

In Modbus RTU mode, the utility generates an Excel Modbus map with register addresses, data types, and scaling for every sensor object — ready to use in controller programming.

SpecificationValue
Part NumberBA/DOM-BLE-EZ
Supply Power15 to 24 VDC or powered through receiver
Power Consumption40 mA max @ 24 VDC
Physical LayerRS-485
Output ProtocolField-selectable: BACnet MS/TP or Modbus RTU
Configuration PortUSB-C (powers module during config — no external power needed)
Bus Cable Distance4,000 ft (1,200 m)
Lost Comm Timeout35 minutes
Operating Temp32 to 140°F (0 to 60°C)
MountingSurface, 2.75 in snaptrack, or 35mm DIN rail
AgencyRoHS (CE pending)
Warranty5 Years
How do I select BACnet MS/TP vs Modbus RTU?
Download the BAPI Device Configuration utility from bapihvac.com. Connect via USB-C (no external power needed), select the protocol, configure baud rate and address, then click Restart.
What does the Modbus map download include?
An Excel spreadsheet with register addresses, data types, input ranges, and notes for every sensor object — ready for controller programming.
What happens when a sensor stops transmitting?
In Modbus mode, an error register for the sensor changes to 1 after 35 minutes. In BACnet mode, Event State turns Fault and Reliability shows Communication Failure.