null Skip to main content
Image coming soon

BAPI BA/BIP-BLE-EZ : Wireless BACnet IP Output Module, Up to 28 Sensors, 10/100 Ethernet

BAPI

MSRP: $285.00
$127.68
(You save $157.32 )
(No reviews yet) Write a Review
SKU:
BA/BIP-BLE-EZ
Condition:
New
Availability:
Ships 3-5 days
Adding to cart… The item has been added
Part Number
BA/BIP-BLE-EZ
 
Protocol
BACnet IP
 
Sensors
Up to 28
 
Ethernet
10/100BASE-TX
 
Lost Comm
35 min
 
Warranty
5 Years

The BAPI BACnet IP Output Module (BA/BIP-BLE-EZ) converts data from up to 28 BAPI BLE wireless sensors into BACnet IP objects for direct integration into the BMS Ethernet network. BACnet IP is an open standard protocol, so this module works with any BACnet-compatible controller or BMS — no proprietary middleware required.

Best for: BAS integrators who need to bring BAPI BLE wireless sensor data directly into a BACnet IP network, eliminating the need for analog output modules when the BMS supports BACnet IP point integration.

5-Year Warranty

Carries BAPI's 5-year warranty. The module auto-discovers all sensors paired to the receiver and creates BACnet objects automatically. Configuration is done through a standard web browser — no proprietary software needed once the module is on the network.

Auto-Discovery — No Manual Object Configuration

When connected to the BAPI BLE Receiver, the BACnet IP module automatically discovers all paired sensors and creates Analog Input and Binary Input BACnet objects for each measured variable. Object names and COV delta values can be customized through the web interface after discovery.

BACnet IP for Up to 28 Sensors

Integrates wireless sensor data directly into the BMS Ethernet backbone. Supports temperature, humidity, setpoint, contact status, battery level, and signal strength objects per sensor.

Web-Based Configuration

Accessible via any browser at the module's DHCP-assigned IP address. Default: UDP port 47808, username admin, password admin. No proprietary software or USB cables needed.

Lost Comm Fault Reporting

If a sensor does not transmit for 35 minutes, the BACnet Event State changes to Fault and Reliability shows Communication Failure. Reverts to Normal within 5 seconds of the next transmission.

Powered Through Receiver or Separately

Powers in-line through the BAPI BLE Receiver, or separately at 15 to 24 VDC using the BA/AOM-CONN kit for remote mounting.

SpecificationValue
Part NumberBA/BIP-BLE-EZ
Supply Power15 to 24 VDC or powered through receiver
Power Consumption40 mA max @ 24 VDC
Ethernet Standard10/100BASE-TX
BACnet UDP Port47808 (default)
Default CredentialsUsername: admin / Password: admin
Lost Comm Timeout35 minutes
Operating Temp32 to 140°F (0 to 60°C)
MountingSurface, 2.75 in snaptrack, or 35mm DIN rail
AgencyRoHS (CE pending)
Warranty5 Years
Do I need to configure BACnet objects manually?
No. The module auto-discovers all sensors paired to the receiver and creates BACnet objects automatically after the sensor has transmitted at least once.
How do I access the web configuration interface?
Connect to a DHCP network, use a BACnet discovery tool to find the IP address, then open it in a browser. Default login: admin/admin.
How do I reset the module?
Hold the Service button 10 seconds to erase network and BACnet settings. Hold 30 seconds total to also erase all sensor objects.
What happens when a sensor stops transmitting?
After 35 minutes, the BACnet object Event State turns Fault and Reliability shows Communication Failure. Reverts to Normal within 5 seconds of the next transmission.