null Skip to main content

Belimo 01CT-5BL : Cable Temperature Sensor, Pt 1000 (1000Ω Platinum RTD), 4" Probe, 6.5 ft Tinned Copper Shielded Plenum Cable, 5-Year Warranty

Belimo

MSRP: $61.00
$27.45
(You save $33.55 )
(No reviews yet) Write a Review
SKU:
01CT-5BL
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
TypeCable Temp Sensor
ElementPt 1000
Probe Length4"
Range-40 to 300°F
Cable6.5 ft tinned copper plenum
EnclosureNEMA 4X / IP67
PowerPassive (no 24V)

The 01CT-5BL is a Belimo passive cable temperature sensor with a Pt 1000 (1000Ω Platinum RTD) sensing element on a 4" stainless steel probe and 6.5 ft of tinned copper shielded plenum cable, green jacket. Use it in an air duct with a separate mounting flange (linked below), or as an immersion sensor with a Belimo thermowell for chilled water, hot water, and process loops. The cable jacket is rated to -40 to 300°F; the stainless steel probe handles the same range. The signal returns directly to the controller as a resistance Ñ no 24V supply or signal conditioning required.

Best For

Duct air, supply and return air, and Ñ with the matching length thermowell Ñ direct immersion in chilled water, hot water, and condenser water. Compact in-line cable design fits clean conduit runs and panel terminations without an exterior junction box.

5-YEAR WARRANTY
Backed by Belimo's industry-leading 5-year factory warranty. ZOT Supply is an authorized Belimo distributor with fast nationwide and international shipping Ñ every unit ships factory-tested with full warranty support.

Key Features

NEMA 4X / IP67 Stainless Probe

Stainless steel sensing probe rated NEMA 4X / IP67. Suitable for duct air, mechanical-room environments, and Ñ with a thermowell Ñ direct fluid immersion.

Drift-Resistant Element

Factory-trimmed Pt 1000 element delivers stable long-term accuracy with no field calibration required.

Liquid-Compatible with Thermowell

Pair with the matching 4" Belimo thermowell (linked below) for direct immersion in chilled water, hot water, condenser water, and process loops.

Direct Resistance Output

Passive resistance returns directly to the controller Ñ no 24V supply, no signal conditioning, no scaling required.

6.5 ft Plenum-Rated Cable

6.5 ft of tinned copper shielded plenum cable, green jacket runs from the probe directly to the controller terminations Ñ no exterior junction box on the duct.

5-Year Belimo Warranty

Industry-leading factory warranty backed by Belimo's worldwide service network.

Technical Specifications

SpecificationDetail
Sensor StyleCable temperature sensor with stainless steel probe
Measured ValueTemperature
Sensing ElementPt 1000 (1000Ω Platinum RTD)
Measuring Range-40...300°F [-40...150°C]
Probe Length4" [100 mm]
Probe Diameter0.24" [6 mm]
Probe MaterialStainless steel
Cable6.5 ft [2 m] tinned copper shielded plenum cable, green jacket, 22AWG, 2-wire, 300 V
Applicationair, water (with thermowell)
MountingSeparate mounting flange (sold separately) for duct, or thermowell for fluid immersion
Process ConnectionCompatible with A-22D-A.. flanges (air) and 1/2" NPT thermowells A-22P-A.. (liquid)
Enclosure RatingNEMA 4X / IP67
Protection ClassIEC/EN III, Protective Extra-Low Voltage (PELV)
UL ApprovalcULus per UL60730-1A/-2-9, CAN/CSA E60730-1/-2-9
Power RequiredNone Ñ passive resistance element
Weight0.15 lb
ManufacturerBelimo
Manufacturer Part Number01CT-5BL
Warranty5-year factory warranty

Compatible Accessories

Mounting Flanges (Air / Duct)
Thermowells (Water / Process Ñ 4" insertion)
Installation Extras

Documentation

Frequently Asked Questions

Does this need 24V power?

No. The 01CT-5BL is a passive resistance temperature sensor Ñ the controller reads its element directly through the analog input. No 24V supply or signal conditioner needed.

What sensing element is in the 01CT-5BL?

The 01CT-5BL uses a Pt 1000 (1000Ω Platinum RTD). The first letter after '01CT-5' identifies the element: A=Pt 100, B=Pt 1000, E=Ni 1000 (JCI), L=NTC 10K Type II, M=NTC 10K Type III (Precon), Q=NTC 20K. Match this to your controller's input curve.

What does the probe length code mean?

The letter after the element code encodes probe length: H=2", L=4", P=8". This SKU has a 4" probe.

Can I use this on a water or chilled-water line?

Yes Ñ pair the sensor with the matching length thermowell from the Compatible Accessories section above. For this 4" probe, see the 4" stainless or brass thermowells listed.

Does it work with my BAS?

Any BAS controller with a temperature input configured for the Pt 1000 curve will read this sensor directly. See the linked Resistance Characteristics PDF for the full curve table at standard temperature points.

How is this different from the 01DT duct sensor?

The 01DT mounts in a NEMA 4X polymer enclosure on the duct exterior with terminals inside the box. The 01CT terminates directly via the cable Ñ no exterior junction box, cleaner installs into a controller panel. Both use the same passive elements and the same family of thermowells when used for liquid immersion.

Sensor Type:
Probe Only
Probe Length:
4 Inch
Temperature Element:
1K Platinum RTD
Lead Length:
6 Foot Plenum Rated Cable
Enclosure:
No Box
Supported Protocols:
None
Humidity Element:
None
CO2 Element:
None
Setpoint:
No Setpoint
Override:
No Override
Display:
No Display