null Skip to main content

Belimo 22DC-51 : Active Duct Air Quality Transmitter, CO2, 0-5V / 0-10V Output, NDIR Dual-Channel CO2, 1 Analog Outputs, NEMA 4X / IP65, 24 VAC/VDC (F + NPT), 5-Year Warranty

Belimo

MSRP: $872.00
$392.40
(You save $479.60 )
(No reviews yet) Write a Review
SKU:
22DC-51
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
TypeDuct Air Quality
MeasuresCO2
Output0–5V / 0–10V
Outputs1× analog
Hardware RevA-22D-A34 (incl. NPT)
Power24 VAC/VDC

The 22DC-51 is a Belimo active 24V duct insertion air quality transmitter (2024 hardware revision: A-22D-A34 mounting flange, 1/2" NPT conduit adapter included) for measuring CO2. The CO2 measurement uses NDIR (non-dispersive infrared) dual-channel technology with self-calibration. Each measurement has its own analog output (1 total), jumper-selectable between 0–5V and 0–10V.

Best For

Demand-controlled ventilation (DCV) on commercial AHUs — modulating outdoor air based on CO2 levels in return air or zone supply. The single CO2 output drives a damper actuator or feeds the BAS for variable OA setpoint logic.

Hardware Revision: 2024 (A-22D-A34, 1/2" NPT adapter included)

This is the newer 2024 hardware revision — ships with the A-22D-A34 mounting flange and includes a 1/2" NPT conduit adapter in the box for direct compliance with US/Canadian/Mexican NFPA conduit installations. Electronics, sensing technology, and accuracy specifications are identical to the earlier 2022 hardware revision (A-22D-A35 flange, no NPT adapter included).

5-YEAR WARRANTY
Backed by Belimo's industry-leading 5-year factory warranty. ZOT Supply is an authorized Belimo distributor with fast nationwide and international shipping — every unit ships factory-tested with full warranty support.

Key Features

1× Independent Analog Output

Each measured value (CO2) has its own dedicated analog output, jumper-selectable between 0-5V and 0-10V. Each output drives its own BAS input independently — no need to time-multiplex or read different addresses.

NDIR Dual-Channel CO2 Sensing

Non-dispersive infrared CO2 measurement with dual optical channels for self-calibration. The dual-channel design eliminates manual recalibration and resists drift from background gases. ±(50 ppm + 3% of measured value) accuracy.

NEMA 4X / IP65 Outdoor-Rated Enclosure

UV-resistant orange polycarbonate enclosure with NBR70 seal. UL94 5VA flame class and UL 2043 plenum compliant for return-air ducts.

Configurable CO2 Range to 5000 ppm

Default CO2 range is 0-2000 ppm, suitable for most occupied-space DCV applications. With the A-22G-A05 accessory, the range extends to 0-5000 ppm for industrial and high-occupancy applications.

5-Year Belimo Warranty

Industry-leading factory warranty backed by Belimo's worldwide service network.

Technical Specifications

SpecificationDetail
Sensor StyleActive duct insertion air quality transmitter — CO2
Measured ValuesCO2
Output Signals1× 0-5V or 0-10V (jumper-selectable, min 10 kΩ load)
Hardware RevisionA-22D-A34 with 1/2" NPT conduit adapter (2024 revision)
CO2 Sensing TechnologyNDIR (non-dispersive infrared), dual-channel with self-calibration
CO2 Measuring Range0-2000 ppm default; 0-5000 ppm with A-22G-A05 accessory
CO2 Accuracy±(50 ppm + 3% of measured value)
CO2 Long-Term Stability±50 ppm per year
CO2 Time Constant τ (63%)Typical 33 s @ 1 m/s air velocity
ApplicationAir — duct insertion
Operating Air Flowmin. 1 ft/s (0.3 m/s); max. 40 ft/s (12 m/s)
MountingSingle-hole duct penetration; A-22D-A34 plastic mounting flange (up to 248°F / 120°C) included
Conduit1/2" NPT conduit adapter included + ø6-8 mm cable gland with strain relief
Power Supply24 VAC/VDC (19–29 VAC, 15–35 VDC)
Power Consumption4.3 VA AC / 2.3 W DC
Electrical ConnectionPluggable spring-loaded terminal block, max 2.5 mm²
Cable EntryCable gland with strain relief, ø6...8 mm
HousingUV-resistant polycarbonate, orange — UL94 5VA
Probe MaterialPA6, black
Enclosure RatingNEMA 4X / IP65 (UL Enclosure Type 4X), UL 2043 plenum compliant
Protection ClassIEC/EN III, SELV; UL Class 2 supply
CertificationIEC/EN 60730-1, CE Marking
ManufacturerBelimo
Manufacturer Part Number22DC-51
Warranty5-year factory warranty

What's In the Box

Parts Included
  • 22DC-51 active duct CO2 transmitter with insertion probe
  • A-22D-A34 mounting flange (plastic, up to 248°F / 120°C)
  • 1/2" NPT conduit adapter

For extended-range CO2 monitoring (up to 5000 ppm) for industrial or high-occupancy applications, see the A-22G-A05 accessory.

Documentation

Frequently Asked Questions

What does the 22DC-51 measure?

This SKU measures CO2. Each measurement has its own dedicated analog output (1 outputs total), so each value can be wired to a separate BAS analog input simultaneously.

What output signals can this provide?

All 1 analog outputs are voltage-only: jumper-selectable between 0-5V and 0-10V per channel, minimum 10 kΩ load resistance. For a 4-20 mA output option, see the universal-output 22DC-53 variant of this same product.

How does NDIR dual-channel CO2 sensing work?

NDIR (non-dispersive infrared) measures CO2 by detecting how much infrared light the gas absorbs at a specific wavelength. The 'dual-channel' design uses a second reference wavelength that CO2 does NOT absorb — by comparing the two signals, the sensor automatically corrects for lamp aging, dirt accumulation on the optics, and background gas interference. This is why the sensor is self-calibrating and rated for ±50 ppm/year long-term stability without manual recalibration.

Does it need 24V power?

Yes. The 22DC-51 requires 24 VAC or 24 VDC (19-29 VAC, 15-35 VDC). Power consumption is 4.3 VA AC / 2.3 W DC — higher than single-variable temperature sensors due to the active CO2 NDIR sensing element.

What air velocity does it need to operate?

Operating air flow range is 1-40 ft/s (0.3-12 m/s). The CO2 NDIR cell needs some air movement past the probe to refresh the gas sample for accurate readings. Below 1 ft/s the reading lags actual duct air composition; above 40 ft/s the response stays accurate but probe vibration becomes a long-term wear concern.

Sensor Type:
Air Quality / Duct
Output Signal:
CO2
Output Style:
Active Transmitter (0-10V)
Power:
24 VAC/VDC
Number of Outputs:
1 analog
CO2 Element:
NDIR Dual-Channel
VOC Element:
None
Temperature Element:
None
Default Temperature Units:
Fahrenheit (°F)
Regional Configuration:
North American (°F + NPT)
CO2 Range:
0-2000 ppm (default); 0-5000 ppm with A-22G-A05
Humidity Element:
None
Display:
No Display
Setpoint:
No Setpoint
Override:
No Override
Supported Protocols:
None (analog)
Enclosure: