Belimo 22DCV-51 : Active Duct Air Quality Transmitter, CO2 + VOC, 0-5V / 0-10V Output, NDIR Dual-Channel CO2, 2 Analog Outputs, NEMA 4X / IP65, 24 VAC/VDC (F + NPT), 5-Year Warranty

Belimo

MSRP: $1,428.00
$642.60
(You save $785.40 )
(No reviews yet) Write a Review
SKU:
22DCV-51
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
TypeDuct Air Quality
MeasuresCO2 + VOC
Output0–5V / 0–10V
Outputs2× analog
Hardware RevA-22D-A34 (incl. NPT)
Power24 VAC/VDC

The 22DCV-51 is a Belimo active 24V duct insertion air quality transmitter (2024 hardware revision: A-22D-A34 mounting flange, 1/2" NPT conduit adapter included) for measuring CO2 and VOC. The CO2 measurement uses NDIR (non-dispersive infrared) dual-channel technology with self-calibration and the VOC measurement uses a metal oxide semiconductor (MOS) gas sensor. Each measurement has its own analog output (2 total), jumper-selectable between 0–5V and 0–10V.

Best For

Indoor air quality monitoring where both CO2 (occupancy proxy) and VOC (off-gassing, cleaning chemicals, paint/printing) need separate signals to the BAS. Common in classrooms, conference rooms, and printing/lab spaces.

Hardware Revision: 2024 (A-22D-A34, 1/2" NPT adapter included)

This is the newer 2024 hardware revision — ships with the A-22D-A34 mounting flange and includes a 1/2" NPT conduit adapter in the box for direct compliance with US/Canadian/Mexican NFPA conduit installations. Electronics, sensing technology, and accuracy specifications are identical to the earlier 2022 hardware revision (A-22D-A35 flange, no NPT adapter included).

5-YEAR WARRANTY
Backed by Belimo's industry-leading 5-year factory warranty. ZOT Supply is an authorized Belimo distributor with fast nationwide and international shipping — every unit ships factory-tested with full warranty support.

Key Features

2× Independent Analog Outputs

Each measured value (CO2, VOC) has its own dedicated analog output, jumper-selectable between 0-5V and 0-10V. Each output drives its own BAS input independently — no need to time-multiplex or read different addresses.

NDIR Dual-Channel CO2 Sensing

Non-dispersive infrared CO2 measurement with dual optical channels for self-calibration. The dual-channel design eliminates manual recalibration and resists drift from background gases. ±(50 ppm + 3% of measured value) accuracy.

Metal Oxide Semiconductor VOC Sensor

MOS-type VOC sensor measures total volatile organic compounds (TVOC) across the 0–5000 ppb range. Detects off-gassing from materials, cleaning chemicals, solvents, and combustion products.

NEMA 4X / IP65 Outdoor-Rated Enclosure

UV-resistant orange polycarbonate enclosure with NBR70 seal. UL94 5VA flame class and UL 2043 plenum compliant for return-air ducts.

Configurable CO2 Range to 5000 ppm

Default CO2 range is 0-2000 ppm, suitable for most occupied-space DCV applications. With the A-22G-A05 accessory, the range extends to 0-5000 ppm for industrial and high-occupancy applications.

5-Year Belimo Warranty

Industry-leading factory warranty backed by Belimo's worldwide service network.

Technical Specifications

SpecificationDetail
Sensor StyleActive duct insertion air quality transmitter — CO2 + VOC
Measured ValuesCO2, VOC
Output Signals2× 0-5V or 0-10V (jumper-selectable, min 10 kΩ load)
Hardware RevisionA-22D-A34 with 1/2" NPT conduit adapter (2024 revision)
CO2 Sensing TechnologyNDIR (non-dispersive infrared), dual-channel with self-calibration
CO2 Measuring Range0-2000 ppm default; 0-5000 ppm with A-22G-A05 accessory
CO2 Accuracy±(50 ppm + 3% of measured value)
CO2 Long-Term Stability±50 ppm per year
CO2 Time Constant τ (63%)Typical 33 s @ 1 m/s air velocity
VOC Sensing TechnologyMetal Oxide Semiconductor (MOS) gas sensor
VOC Measuring Range0–100% VOC (0–5000 ppb TVOC equivalent)
ApplicationAir — duct insertion
Operating Air Flowmin. 1 ft/s (0.3 m/s); max. 40 ft/s (12 m/s)
MountingSingle-hole duct penetration; A-22D-A34 plastic mounting flange (up to 248°F / 120°C) included
Conduit1/2" NPT conduit adapter included + ø6-8 mm cable gland with strain relief
Power Supply24 VAC/VDC (19–29 VAC, 15–35 VDC)
Power Consumption4.3 VA AC / 2.3 W DC
Electrical ConnectionPluggable spring-loaded terminal block, max 2.5 mm²
Cable EntryCable gland with strain relief, ø6...8 mm
HousingUV-resistant polycarbonate, orange — UL94 5VA
Probe MaterialPA6, black
Enclosure RatingNEMA 4X / IP65 (UL Enclosure Type 4X), UL 2043 plenum compliant
Protection ClassIEC/EN III, SELV; UL Class 2 supply
CertificationIEC/EN 60730-1, CE Marking
ManufacturerBelimo
Manufacturer Part Number22DCV-51
Warranty5-year factory warranty

What's In the Box

Parts Included
  • 22DCV-51 active duct CO2 + VOC transmitter with insertion probe
  • A-22D-A34 mounting flange (plastic, up to 248°F / 120°C)
  • 1/2" NPT conduit adapter

For extended-range CO2 monitoring (up to 5000 ppm) for industrial or high-occupancy applications, see the A-22G-A05 accessory.

Documentation

Frequently Asked Questions

What does the 22DCV-51 measure?

This SKU measures CO2, VOC. Each measurement has its own dedicated analog output (2 outputs total), so each value can be wired to a separate BAS analog input simultaneously.

What output signals can this provide?

All 2 analog outputs are voltage-only: jumper-selectable between 0-5V and 0-10V per channel, minimum 10 kΩ load resistance. For a 4-20 mA output option, see the universal-output 22DCV-53 variant of this same product.

How does NDIR dual-channel CO2 sensing work?

NDIR (non-dispersive infrared) measures CO2 by detecting how much infrared light the gas absorbs at a specific wavelength. The 'dual-channel' design uses a second reference wavelength that CO2 does NOT absorb — by comparing the two signals, the sensor automatically corrects for lamp aging, dirt accumulation on the optics, and background gas interference. This is why the sensor is self-calibrating and rated for ±50 ppm/year long-term stability without manual recalibration.

What does VOC measure and what range does it cover?

VOC = Volatile Organic Compounds — gases released by paints, solvents, cleaning products, off-gassing materials, cooking, and combustion. The metal oxide semiconductor sensor measures total VOC (TVOC) from 0-100% relative concentration (equivalent to roughly 0-5000 ppb TVOC). Output scales linearly across the range. VOC is typically monitored as a relative trend rather than a calibrated absolute value — a sudden VOC spike is a meaningful BAS event regardless of the absolute ppb number.

How do I choose between DCK, DCM, and DCV?

DCK = CO2 + VOC + Temperature + CO2/VOC Mix (4 outputs, max IAQ coverage). DCM = CO2 + VOC + Temperature (3 outputs, no mix value). DCV = CO2 + VOC only (2 outputs, no temperature). Choose by which signals your BAS actually uses — there's no benefit to paying for outputs you won't wire. If you need temperature at the same duct location and want to consolidate sensors, DCM or DCK eliminate a separate 22DT install.

Does it need 24V power?

Yes. The 22DCV-51 requires 24 VAC or 24 VDC (19-29 VAC, 15-35 VDC). Power consumption is 4.3 VA AC / 2.3 W DC — higher than single-variable temperature sensors due to the active CO2 NDIR sensing element.

What air velocity does it need to operate?

Operating air flow range is 1-40 ft/s (0.3-12 m/s). The CO2 NDIR cell needs some air movement past the probe to refresh the gas sample for accurate readings. Below 1 ft/s the reading lags actual duct air composition; above 40 ft/s the response stays accurate but probe vibration becomes a long-term wear concern.

Can I configure this sensor with the Belimo Duct Sensor Assistant App?

Yes. The Belimo Duct Sensor Assistant App (iOS / Android) connects to this sensor via the A-22G-A05 Bluetooth dongle for parametrization — adjusting CO2 scaling (2000 / 5000 ppm), output mapping, and (on multi-variable sensors) the CO2/VOC mix ratio. Most installations don't require this — the sensor arrives pre-configured with sensible defaults — but it's available for advanced or non-standard applications. See the Documentation section above for the app brochure.

Sensor Type:
Air Quality / Duct
Output Signal:
CO2 + VOC
Output Style:
Active Transmitter (0-10V)
Power:
24 VAC/VDC
Number of Outputs:
2 analog
CO2 Element:
NDIR Dual-Channel
VOC Element:
Metal Oxide Semiconductor
Temperature Element:
None
Default Temperature Units:
Fahrenheit (°F)
Regional Configuration:
North American (°F + NPT)
CO2 Range:
0-2000 ppm (default); 0-5000 ppm with A-22G-A05
Humidity Element:
None
Display:
No Display
Setpoint:
No Setpoint
Override:
No Override
Supported Protocols:
None (analog)
Enclosure:
NEMA 4X Enclosure