Belimo 22HL-520 : Liquid Leakage Switch, Conductivity Sensing (~10 uS), Rope/Cable Detection 65 ft (20 m), SPDT Relay (1A @ 24V) Output, LED Indicator (Green/Red), Automatic Reset, 24 VAC/VDC, 1/2" NPT Conduit, NEMA 4 / IP65, 5-Year Warranty

Belimo

MSRP: $778.00
$350.10
(You save $427.90 )
(No reviews yet) Write a Review
SKU:
22HL-520
Condition:
New
Availability:
Ships Today
Adding to cart… The item has been added
TypeLeakage Switch
SensingConductivity (~10 µS)
DetectionRope/Cable (65 ft / 20 m)
Output1× SPDT dry contact
Sw Current1 A @ 24 V
LEDGreen / Red
ResetAutomatic
EnclosureNEMA 4 / IP65

The 22HL-520 is a Belimo leakage switch for detecting liquid leaks in HVAC and building applications: false floors, suspended ceilings, mechanical rooms, server room sub-floors, AHU drain pans, container monitoring, and any installation where unintended water or water-glycol presence requires alarm or control response. The sensor uses rope/cable detection via a 65 ft (20 m) long leak-detection sensing cable — any liquid contact anywhere along the cable triggers the alarm, with a conductivity threshold of approximately 10 µS — sensitive enough for clean water but immune to humidity and ambient moisture. Output is one SPDT changeover relay with dry contact rated for max. 1 A switching current at 24 V — wires directly into a controller alarm input, or in series with a Belimo shut-off valve to interrupt water flow automatically when a leak is detected. The unit features an on-housing LED indicator (green for power OK, red for active leak detection) and automatic reset after the sensing contacts dry — no manual reset required after a transient event. The polycarbonate housing (transparent top cover for LED visibility, orange UL94 5VA bottom) is rated NEMA 4 / IP65 for wet and washdown environments. A 1/2" NPT conduit adapter ships with the unit for direct connection to standard electrical conduit.

Best For

Area leak detection over an extended path — server room sub-floors, data center cold aisles, suspended ceilings above critical equipment, computer rooms, telecommunications equipment rooms, and any large area where a leak could happen anywhere along the perimeter. The 65 ft (20 m) detection cable runs along the floor or in a tray; contact with liquid at any point along the cable triggers the relay. Particularly valuable in IT/data-center applications where leak detection is mandated by mission-critical facility standards (Tier III/IV uptime). Other 22HL variants: 22HL-50 (point detection), 22HL-502 (point detection, dual relay output), 22HL-505 (16.4 ft detection cable).

On-Housing LED Indicator

The on-housing LED gives a clear visual status without needing to check the BAS: green when powered and sensing normally, red when liquid is detected at the sensing contacts. The transparent polycarbonate top cover lets the LED be read at a glance during walkthroughs or service calls. The unit automatically resets to green once the contacts dry — no manual reset, no field re-arming.

5-YEAR WARRANTY
Backed by Belimo's industry-leading 5-year factory warranty. ZOT Supply is an authorized Belimo distributor with fast nationwide and international shipping — every unit ships factory-tested with full warranty support.

Key Features

Rope/Cable Detection — 65 ft (20 m)

Leak-detection sensing cable runs along floors, equipment perimeters, or suspended drain trays — liquid contact ANYWHERE along the cable length triggers the relay. Covers extended areas (server room cold aisles, data center sub-floors, multi-equipment skids) with a single sensor — vs deploying multiple point sensors and aggregating their outputs.

Conductivity-Based Sensing (~10 µS Threshold)

Detection triggers at approximately 10 µS conductivity — sensitive enough to detect tap water and water-glycol mixtures, but immune to ambient humidity and condensation on the housing exterior. The sensing contacts respond to actual liquid presence, not damp air.

On-Housing Status LED (Green / Red)

Green LED indicates normal power-on operation; red LED indicates active leak detection. Visible through the transparent PC top cover — facility staff and service technicians can verify sensor status at a glance without checking the BAS or opening the housing.

Automatic Reset After Drying

The relay returns to normal state automatically once the sensing contacts dry. No manual reset button, no field re-arming after a transient event — particularly valuable for installations where access is difficult (suspended ceilings, sub-floors) or where leak events may be brief and self-clearing.

SPDT Changeover Dry Contact

Single dry-contact relay output — max 1 A switching current at 24 V, min 3 mA at 10 V. Wires directly to controller alarm inputs, Belimo motorized valve coils (for direct in-series shut-off), or third-party annunciator panels. Dry contact (no internal power source) — installer supplies the load-side voltage.

NEMA 4 / IP65 Enclosure

Transparent polycarbonate top cover (for LED visibility) with orange UL94 5VA polycarbonate bottom, sealed with NBR70 gasket. UV-resistant for installations near exterior light. Rated NEMA 4 / IP65 for wet and washdown environments — appropriate for the leak-detection application where the sensor itself may be exposed to the liquid it's monitoring for.

24V AC/DC Power

Compatible with standard 24V control transformers shared with actuators and other sensors. AC 21.6-26.4V or DC 13.5-26.4V supported. Power consumption: 1.5 VA AC / 0.6 W DC — very low draw.

1/2" NPT Conduit Adapter Included

Conduit adapter ships in the box for direct connection to standard 1/2" NPT electrical conduit. Cable gland with strain relief supports ø6-8 mm cable diameter for installations without conduit. Pluggable spring-loaded terminal block (max 2.5 mm²) for sensor and load-side wiring.

5-Year Belimo Warranty

Industry-leading factory warranty backed by Belimo's worldwide service network.

Technical Specifications

SpecificationDetail
Sensor StyleLiquid leak detection switch
Measured ValueLiquid presence (conductivity-based)
Measuring FluidWater, water-glycol mixtures
Sensing PrincipleConductivity
Switching Threshold≈10 µS
Detection MethodRope/cable detection — 65 ft (20 m) sensing cable
Sensing Cable Length65 ft (20 m)
Output Type1× SPDT changeover dry contact
Max Switching Current1 A @ 24 V
Min Switching Current3 mA @ 10 V
ResetAutomatic after contacts dry
DisplayLED — Green (power OK), Red (leak/liquid present)
Power Supply24 VAC/VDC (AC 21.6-26.4V / DC 13.5-26.4V)
Power Consumption1.5 VA AC / 0.6 W DC
Electrical ConnectionPluggable spring-loaded terminal block, max 2.5 mm²
Cable EntryCable gland with strain relief, ø6-8 mm; 1/2" NPT conduit adapter included
Housing — Top CoverPolycarbonate, transparent (UV resistant, UL94 5VA)
Housing — BottomPolycarbonate, orange (UV resistant, UL94 5VA)
Housing SealNBR70, black
Cable GlandPA6, black
Enclosure RatingNEMA 4 / IP65
Protection ClassIEC/EN III, PELV (Protective Extra-Low Voltage)
Pollution Degree3
Type of ActionType 1.B
Rated Impulse Voltage0.8 kV
Ambient Temperature-4 to 158°F (-20 to 70°C); brief excursion to 185°F (85°C) max 10 minutes
Fluid Temperature-4 to 158°F (-20 to 70°C)
Ambient HumidityMax. 95% RH, non-condensing
EU ConformityCE Marking
CertificationIEC/EN 60730-1
Quality StandardISO 9001
ManufacturerBelimo
Manufacturer Part Number22HL-520
Warranty5-year factory warranty

What's In the Box

Parts Included
  • 22HL-520 leakage switch in transparent/orange polycarbonate housing
  • 65 ft (20 m) factory-supplied leak detection sensing cable
  • 1/2" NPT conduit adapter
  • Cable tie
  • Mounting dowels
  • Mounting screws

Documentation

Frequently Asked Questions

What does the 22HL-520 detect and how does it signal a leak?

It detects the presence of liquid (water or water-glycol mixtures) via conductivity sensing at the sensing contacts, with a threshold of approximately 10 µS. Detection happens anywhere along a 65 ft (20 m) sensing cable that runs along the floor or area being monitored. When liquid is detected, the SPDT relay activates, changing state from normal to alarm position. The on-housing red LED illuminates to show the alarm condition visually. After the sensing contacts dry, the unit automatically resets — no manual intervention needed.

How do I install a 65-ft leak detection cable?

The sensing cable runs along the floor, perimeter, or critical area where you want leak coverage. Common deployment: lay the cable in serpentine pattern under a raised floor in a server room, or along the perimeter of a mechanical equipment skid, or in trays beneath suspended cooling coils. Secure with installer-supplied cable ties (one is included for the sensor housing itself, but additional ties for the run length are not supplied). The cable's outer jacket is conductive on two parallel conductors — when water bridges them at any point along the length, the conductivity threshold is crossed and the sensor triggers. Avoid running the cable directly under HVAC drip pans where condensation could cause nuisance alarms; aim for the floor itself where only real leak water would pool.

Where should I install this sensor?

Run the 65 ft sensing cable along the floor or critical perimeter of the area you want to protect. Server room sub-floors, data center cold aisles, telecommunications equipment rooms, suspended ceilings above critical equipment, and large mechanical room floors are typical applications. The sensor itself (the housing) mounts on a wall or panel near the cable's start point, with the cable extending out from there. Avoid running the cable directly under HVAC drip pans where normal condensation could cause nuisance alarms.

What media can this sensor detect?

Water and water-glycol mixtures — anything with conductivity above the ~10 µS threshold. This includes essentially all hydronic system fluids (chilled water, hot water, condenser water, glycol loops). The sensor will NOT reliably detect: deionized water (too low conductivity), oils, refrigerants, fuels, or non-conductive solvents. For oil or fuel leak detection, a different sensing technology is required (typically optical or hydrocarbon-specific). Operating fluid temperature range is -4 to 158°F (-20 to 70°C).

How is the relay output wired?

SPDT (Single Pole Double Throw) changeover dry contact — three terminals: Common (C), Normally Open (NO), Normally Closed (NC). The relay is a passive dry contact, no internal voltage source. Wire the load circuit's voltage through C and NO (for normally-open behavior — circuit closes on alarm) or through C and NC (for normally-closed behavior — circuit opens on alarm, fail-safe). Max switching current is 1 A at 24 V; min is 3 mA at 10 V. Use NC wiring for fail-safe applications where loss of sensor power should also trigger the alarm condition.

Does the sensor reset automatically after a leak event?

Yes. After the sensing contacts dry (no longer detect conductive liquid), the relay automatically returns to normal state and the LED returns to green. No manual reset button to press, no field re-arming required. This is particularly valuable for installations in hard-to-access locations (suspended ceilings, sub-floors) where a manual-reset sensor would require an extra service call after every transient event. If the BAS needs to record the alarm event for audit purposes, the controller should latch the alarm signal internally — the sensor's own reset is automatic and doesn't preserve event history.

How does this differ from the other 22HL variants?

All 22HL variants share the same chassis, conductivity sensing principle, auto-reset behavior, NEMA 4 / IP65 housing, and 24 VAC/VDC power. The differences are: 22HL-50 = point detection on housing, 1× SPDT 1A relay; 22HL-502 = point detection, 2× SPDT 3A relays (dual, isolated); 22HL-505 = 16.4 ft (5 m) rope/cable detection, 1× SPDT; 22HL-520 = 65 ft (20 m) rope/cable detection, 1× SPDT. Choose point detection for known leak locations (drain pans, equipment bases); choose rope detection for extended areas (server rooms, data center sub-floors). Choose the dual-relay 22HL-502 when you need simultaneous valve-shutoff and BAS-alarm actions from a single sensor.

Does it need 24V power?

Yes. 24 VAC or 24 VDC supported (AC 21.6-26.4V / DC 13.5-26.4V). Power consumption is 1.5 VA AC / 0.6 W DC — very low draw, compatible with standard 24V control transformers shared with actuators and other sensors. Note that the relay output is a dry contact (passive) — the supply voltage to the load circuit must be provided externally.

Sensor Type:
Leakage Switch / Liquid Detection
Sensing Principle:
Conductivity
Switching Threshold:
≈10 µS
Compatible Media:
Water / Water-Glycol Mixture
Detection Method:
Rope/Cable (65 ft / 20 m)
Sensing Cable Length:
65 ft (20 m)
Output Type:
1× SPDT changeover dry contact
Number of Relays:
1
Max Switching Current:
1 A @ 24 V
Reset Type:
Automatic (after contacts dry)
Display:
LED (Green / Red)
Power:
24 VAC/VDC
Power Consumption:
1.5 VA AC / 0.6 W DC
Conduit:
1/2 NPT (included)"
Housing Material:
Polycarbonate (transparent top + orange bottom)
Seal Material:
NBR70
Enclosure:
NEMA 4 / IP65
Mounting:
Surface (wall/floor)
Supported Protocols:
Dry contact relay (no bus, no analog)