null Skip to main content

Belimo Z2050Q-F+CQKX24-SR : 2-Way 1/2" ZoneTight Zone Valve, NPT, Cv 1.4, Electronic Fail-Safe Actuator, 24 VAC/DC, Modulating 2-10 VDC or 0.5-10 VDC Control Signal, 5-Year Warranty, (Customizable Product)

Belimo

MSRP: $529.00
Your Price:  $238.05
(You save $290.95 )
(No reviews yet) Write a Review
SKU:
Z2050Q-F+CQKX24-SR
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
ValveZ2050Q-F, 2-way, 1/2″ NPT
Cv1.4
ActuatorCQKX24-SR Electronic Fail-Safe
Power24 VAC/DC
ControlModulating 2-10 VDC or 0.5-10 VDC
Close-off75 psi
Warranty5 years

The Belimo Z2050Q-F+CQKX24-SR is a 2-way, 1/2″ NPT ZoneTight ball zone valve (Cv 1.4, 75 psi close-off, 0% leakage) factory-assembled with the CQKX24-SR, an electronic fail-safe actuator that drives the valve to its fail position (not printed on the supplied data sheet; see source note below) on loss of power. The actuator runs on AC 24 V and accepts a modulating 2...10 V control signal (4...20 mA with the ZG-R01 500 Ω resistor) and provides 2...10 V position feedback. This is an 'X' model: Belimo ships X-model actuators with a factory clip setting for the maximum flow, ordered to your design Cv.

Specifications on this page are taken from the Belimo Z2050Q-F+CQKX24-SR assembly technical data sheet (valve section revision 2024-06-12, CQKX24-SR actuator section revision 2024-06-27), the CQK quick-mount instruction manual 71775-00001.L and the Belimo ZoneTight brochure (PF_37, 05/25). Verified 2026-09-09.

Best For

Unit ventilators, fan coil units, VAV reheat coils, fin tube casing, radiant panels and duct coils in large commercial buildings (Belimo's listed QCV applications), with modulating zone control from a controller supplying 2...10 V or 0.5...10 V where the coil must fail to a defined position on power loss. Belimo lists the QCV for installations where higher close-off and the ability to change flow are desired, in space-restricted areas.

Key Features

Zero Leakage Shutoff

Belimo publishes a 0% leakage rate and a 75 psi close-off pressure for the Z2050Q-F, with a 360 psi body rating.

Field-Adjustable Maximum Flow

An end-stop clip on the actuator changes the angle of rotation in 2.5° increments to set the maximum flow, from Cv 0.1 up to the full Cv 1.4, without tools.

Tool-Free Snap Assembly

The actuator plugs onto the valve by hand in vertical movements only; pins must match the holes on the flange. Mounting orientation can be selected in 180° increments.

Electronic Fail-Safe

On loss of power the actuator drives the valve to its fail position (see source note) in under 60 s (published fail-safe running time), with a 2 s bridging time and 5...20 s pre-charging time.

Configurable Modulating Control

The data sheet publishes 2...10 V and 0.5...10 V operating ranges with matching 2...10 V / 0.5...10 V position feedback; 4...20 mA with the ZG-R01 500 Ω resistor. Signal direction, control range and end-stop position are configured at order.

Plenum Rated, cULus Listed

UL 2043 compliant for use in air plenums per NEC 300.22(C) and IMC 602; cULus listed to UL60730-1A/-2-14 and CAN/CSA E60730-1:02, UL Enclosure Type 2 / NEMA 2 / IP40.

Technical Specifications — Valve

SpecificationDetail
Valve TypeZoneTight (QCV) ball zone valve, 2-way
Valve Size1/2″ [DN 15]
Pipe ConnectionInternal thread, NPT (female)
Cv1.4
Flow CharacteristicEqual percentage
Leakage Rate0%
FluidChilled or hot water, up to 60% glycol
Fluid Temperature Range (water)36...212°F [2...100°C]
Body Pressure Rating360 psi
Close-off Pressure Δps75 psi
Differential Pressure Δpmax40 psi
Angle of RotationOperating range 15...90°
Controllable Flow Range75°
Flow DirectionDirection of flow in both directions possible
Installation OrientationUpright to horizontal (in relation to the spindle); not in a hanging position with the stem pointing downwards
ServicingMaintenance-free
Valve BodyForged brass
StemBrass
Stem SealEPDM O-ring
SeatPTFE, O-ring EPDM
O-ringEPDM (lubricated)
BallChrome plated brass
Suitable ActuatorsNon fail-safe CQB(X); electronic fail-safe CQKB(X)
Valve Weight0.31 lb [0.14 kg] (TDS rev 2026-02-07); 0.15 lb [0.070 kg] (2024-06-12 revision) — see note
Assembly Dimensions (CQK actuator)A 4.5″ [114] · B 2.0″ [52] · C 3.3″ [83] · D 2.7″ [69] · E 0.9″ [24] · F 0.9″ [24] — drawing on data sheet p. 3
Field Flow Setting (end-stop clip)position 1 = Cv 0.1; position 3- = Cv 0.2; position 4+ = Cv 0.4; position 5+ = Cv 0.6; position 6 = Cv 0.8; position N = Cv 1.2; position No end stop = Cv 1.4 (V'nom)
Source note (valve weight): Belimo's Z2050Q-F technical data sheet revision 2026-02-07 lists the valve body at 0.31 lb [0.14 kg]; the 2024-06-12 revision of the same valve section, still bundled in most Belimo assembly data sheets, lists 0.15 lb [0.070 kg]. Both figures are shown here as published; the newer revision is listed first.

Technical Specifications — CQKX24-SR Actuator

SpecificationDetail
ActuatorCQKX24-SR — Modulating, Electronic fail-safe, 24 V, ZoneTight CQK family
X Model (configurable)Belimo lists CQKX24-SR as a configurable actuator. Selected at order in the Belimo configurator: setup 3 NO/FO, 4 NO/FC, 5 NC/FO or 6 NC/FC; control range 2...10 V or 0.5...10 V; angle limitation (end-stop position); delivery position open or closed (belimo.com configurator, 2026-09-07). The data sheet does not fix a normally open or normally closed designation.
ControlModulating 2...10 V (4...20 mA with ZG-R01 500 Ω resistor)
Nominal VoltageAC 24 V
Nominal Voltage Frequency50/60 Hz
Nominal Voltage RangeAC 19.2...28.8 V / DC 21.6...28.8 V
Power Consumption in Operation2.5 W
Power Consumption in Rest Position0.5 W
Transformer Sizing5 VA
Electrical Connection22 GA plenum cable, 3 ft [1 m], 10 ft [3 m] or 16 ft [5 m], with 1/2″ NPT conduit connector
Overload Protectionelectronic throughout 0...90° rotation
Electrical Protectionactuators are double insulated
Operating Range Y2...10 V
Operating Range Y (note)4...20 mA w/ ZG-R01 (500 Ω, 1/4 W resistor)
Operating Range Y (variable)0.5...10 V
Position Feedback U2...10 V
Position Feedback U (variable)0.5...10 V
Bridging Time (PF)2s
Pre-charging Time5...20 s
Angle of Rotation90°, adjustable with mechanical stop
Running Time (Motor)75 s / 90°
Running Time Fail-Safe<60 s
Noise Level, Motor35 dB(A)
Noise Level, Fail-Safe35 dB(A)
Position Indicationpointer
Power Source ULClass 2 Supply
Degree of Protection IEC/ENIP40
Degree of Protection NEMA/ULNEMA 2
EnclosureUL Enclosure Type 2
Agency ListingcULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02 CE acc. to 2014/30/EU and 2014/35/EU
Quality StandardISO 9001
UL 2043Suitable for use in air plenums per Section 300.22(C) of the NEC and Section 602 of the IMC
Ambient HumidityMax. 95% RH, non-condensing
Ambient Temperature35...104°F [2...40°C]
Storage Temperature-40...176°F [-40...80°C]
Housing MaterialUL94-5VA
Actuator Weight0.43 lb [0.20 kg]
ManufacturerBelimo
Manufacturer Part NumberZ2050Q-F+CQKX24-SR
Warranty5 years
Source note (supply): the CQKX24-SR data sheet prints a nominal voltage of AC 24 V while its nominal voltage range and installation notes also list DC 21.6...28.8 V / DC 24 V.

Documentation

Related Products

Frequently Asked Questions

What is the Belimo Z2050Q-F+CQKX24-SR?

It is Belimo's Z2050Q-F 2-way 1/2″ NPT ZoneTight zone valve (Cv 1.4) supplied as a factory assembly with the CQKX24-SR electronic fail-safe actuator, which accepts a modulating 2...10 V control signal (4...20 mA with the ZG-R01 500 Ω resistor) and provides 2...10 V position feedback and runs on AC 24 V.

What happens on loss of power?

The CQKX24-SR is electronic fail-safe: Belimo publishes a fail-safe running time of under 60 s to its fail position (see source note above), with a 2 s bridging time and a 5...20 s pre-charging time after power-up.

What transformer or supply does the CQKX24-SR need?

Belimo lists a nominal voltage of AC 24 V (range AC 19.2...28.8 V / DC 21.6...28.8 V, 50/60 Hz), transformer sizing 5 VA, power consumption 2.5 W in operation and 0.5 W at rest. Actuators may be connected in parallel; power consumption and input impedance must be observed.

What control signal does the CQKX24-SR accept?

Modulating 2...10 V, with 2...10 V position feedback. A 500 Ω ZG-R01 resistor converts a 4...20 mA control signal to 2...10 V.

What does the X in CQKX24-SR mean?

X-model ZoneTight actuators are Belimo's configurable versions. The ZoneTight brochure instructs to order X models for a factory clip (end-stop) setting, so maximum flow is set at the factory rather than shipping at the full Cv 1.4. Belimo's configurator for CQKX24-SR also selects the setup (NO/FO, NO/FC, NC/FO, NC/FC), 2...10 V or 0.5...10 V control range and delivery position.

Can the maximum flow of the Z2050Q-F be adjusted in the field?

Yes. The actuator end-stop clip changes the angle of rotation in 2.5° increments; published Z2050Q(S)-F positions are position 1 = Cv 0.1; position 3- = Cv 0.2; position 4+ = Cv 0.4; position 5+ = Cv 0.6; position 6 = Cv 0.8; position N = Cv 1.2; position No end stop = Cv 1.4 (V'nom). On modulating actuators an adaptation must be triggered after any clip change.

Is the CQKX24-SR rated for plenum installation?

Yes. Belimo lists it as UL 2043 compliant and suitable for use in air plenums per NEC Section 300.22(C) and IMC Section 602, with UL Enclosure Type 2 / NEMA 2 / IP40 protection.

What is the warranty on the Z2050Q-F+CQKX24-SR?

Belimo warrants ZoneTight components for 5 years from the date of production. Belimo notes the warranty is invalidated if the fluid exceeds 212°F due to a boiler control failure.

5-YEAR WARRANTYBelimo warrants all ZoneTight components for a period of 5 years from the date of production (Belimo Zone Valve Guide Specification, Section 230900, rev. July 22, 2025; the ZoneTight brochure lists a comprehensive 5-year warranty). ZOT Supply is an authorized Belimo distributor with fast nationwide and international shipping; every unit ships factory-fresh with full warranty support. Note from the Belimo data sheet: if fluid temperature exceeds the 212°F operating range due to a boiler control failure the valve will contain the water, but the manufacturer's warranty becomes invalid.
Valve Pattern:
2-Way
Valve Size:
1/2 Inch
Connection Type:
NPT
CV Rating:
1.4
Actuator Type:
Fail-Safe
Voltage:
24VAC/DC
Control Signal:
2-10VDC
Auxillary Switch:
None