null Skip to main content

Contemporary Controls EIS8-100T : 8-Port Unmanaged Ethernet Switch, UL 864 10th Edition Recognized Component for Fire Alarm Systems, 10/100 Mbps, UL 508 Listed, DIN-Rail or Panel Mount, 10-36VDC / 8-24VAC with Battery Backup Support

Contemporary Controls

MSRP: $801.00
$736.92
(You save $64.08 )
(No reviews yet) Write a Review
SKU:
EIS8-100T
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
UL 864Recognized Component
Ports8 × 10/100 RJ-45
Power Input10-36VDC / 8-24VAC
Battery BackupSupported (AC mode)
Operating Temp0°C to +60°C
MountingDIN-Rail or Panel
Warranty2 Years

The Contemporary Controls EIS8-100T EIS Ethernet Switch is an unmanaged Ethernet switch built for fire alarm and smoke control system applications. It is a UL 864 10th Edition Recognized Component, pre-qualified by UL for incorporation into UL Listed fire alarm system end-products without independent component-level retesting. The switch combines 8 RJ-45 copper ports (10/100 Mbps) providing pure-copper Ethernet expansion for fire alarm panels and control systems, with full plug-and-play operation requiring no IP address, web interface, or firmware setup. Power options include 10-36 VDC, 8-24 VAC, diode-isolated redundant DC inputs, and an AC + battery backup mode for fire alarm power continuity. An adjustable mounting bracket allows the same SKU to be either DIN-rail or panel mounted.

Best For
Fire alarm and smoke control systems requiring an all-copper UL 864 Recognized Component Ethernet switch with 8 device drops. UL 864 10th Edition Recognized Component for use in fire alarm and smoke control systems. Because the EIS series is pre-qualified by UL as a component, fire alarm system manufacturers and integrators can incorporate it into their UL Listed end products without independent component-level testing — significantly reducing certification time. Also UL 508 Listed for Industrial Control Equipment and ULC-S527-11 compliant for Canadian fire alarm installations. Indoor / climate-controlled enclosures only.
2-Year WarrantyBacked by Contemporary Controls' 2-year limited warranty against defects in materials and workmanship.

UL 864 Fire Alarm Compliance

  • UL 864 10th Edition Recognized Component
  • Pre-qualified for use in UL Listed fire alarm systems
  • ULC-S527-11 compliant (Canadian fire alarm)
  • UL 508 Listed for Industrial Control Equipment
  • Covered under UL Follow-Up Surveillance program

8 Copper Ports, Plug-and-Play

  • 8 × 10/100 Mbps shielded RJ-45 ports
  • Auto-negotiation of speed and duplex on all ports
  • Auto-MDIX accepts straight-through or crossover cables
  • Store-and-forward switching, non-blocking wire-speed
  • 2K MAC address table, 300 second aging
  • ANSI/IEEE 802.3 compliant

Flexible Power with Battery Backup

  • Wide-range input: 10-36 VDC (6 W) or 8-24 VAC (6 VA)
  • Diode-isolated redundant DC inputs supported
  • AC powered with battery backup mode (AC fail rollover)
  • 4-pin removable keyed power connector
  • Reverse-polarity protection on inputs

Adjustable Mount & Diagnostic LEDs

  • Adjustable bracket: TS-35 DIN-rail OR panel mount
  • Single SKU for both mounting styles
  • Power LED (green) for supply status
  • Per-port LINK LED (green): solid=link, flashing=data
  • Per-port HS LED (yellow): glows at 100 Mbps
  • Rugged metal enclosure
Specifications
Total Ports8
Ports8 × 10BASE-T/100BASE-TX, shielded RJ-45, Auto-MDIX
Data Rate10/100 Mbps, auto-negotiated, half or full duplex
Switching ModeStore-and-forward, non-blocking (full wire-speed)
MAC Address Table2,048 entries (2K), 300-second inactivity aging
Data Storage768 Kbits SRAM, 512 byte blocks
IEEE StandardANSI/IEEE 802.3
Flow ControlPAUSE function (full-duplex), backpressure (half-duplex)
Power Input10-36 VDC (6 W) or 8-24 VAC (6 VA), 47-63 Hz
Power Connector4-pin removable keyed connector
Power RedundancyDiode-isolated redundant DC inputs supported (both must supply rated power)
Battery BackupAC powered with battery backup mode (battery charged externally; switch does not charge)
Operating Temperature0°C to +60°C (+32°F to +140°F)
Storage Temperature-40°C to +85°C
Humidity10-95%, non-condensing
Protection RatingIP30
MountingTS-35 DIN-rail (clip pre-attached) OR panel mount via extendable brackets (#8 pan-head screws, not included)
Dimensions (DIN-rail)39 × 140 × 156 mm (1.53 × 5.51 × 6.14 in)
Dimensions (Panel)44.5 × 140 × 191 mm (1.75 × 5.51 × 7.52 in) with brackets extended
Shipping Weight1 lb (0.45 kg) data sheet; 2 lb (0.9 kg) install guide
EnclosureRugged metal
Wire Size (Power)16-20 AWG solid, 16-18 AWG stranded
RegulatoryUL 864 10th Ed. Recognized Component (Fire Alarm Systems), UL 508 Listed (Industrial Control Equipment), c-UL Listed (CSA 22.2 No. 14-M91), ULC-S527-11, CE Mark, FCC Part 15 Class A, RoHS
UL 508A CompatibilityDirectly acceptable as UL 508 Listed Industrial Control Equipment in UL 508A panels
Warranty2-year limited (Contemporary Controls)

Frequently Asked Questions

What does UL 864 10th Edition Recognized Component mean for me?

The EIS8-100T has been pre-qualified by UL as a Recognized Component for use in fire alarm and smoke control systems under UL 864 10th Edition. This is different from a UL Listed end-product: a Recognized Component is intended to be incorporated into a larger UL Listed system (such as a fire alarm panel) where the system manufacturer takes responsibility for the end-product listing. Using a UL Recognized Component streamlines the qualification process for the end-product because the component itself has already been tested against UL's component-level safety standards. For fire alarm system suppliers, this means no additional component-level testing is required to incorporate the EIS8-100T into a UL 864-listed end product.

What standards does UL 864 10th Edition cover?

UL 864 10th Edition governs the safety of fire alarm systems and equipment in accordance with NFPA 12 (CO2), NFPA 12A (Halon 1301), NFPA 13 (Sprinkler Systems), NFPA 15 (Water Spray), NFPA 16 (Foam-Water), NFPA 17/17A (Dry/Wet Chemical), NFPA 70 (National Electrical Code), NFPA 72 (National Fire Alarm Code), NFPA 92A/92B (Smoke Control), and NFPA 2001 (Clean Agent). All new fire alarm and smoke control systems claiming UL 864 compliance must comply with this latest 10th Edition.

What if I need a fibre backbone for fire alarm interconnects?

The EIS8-100T is the all-copper variant (8 RJ-45 ports). If your installation requires a fibre uplink for galvanic isolation, lightning protection, or longer cable runs between cabinets, see the EIS6-100T/FC (multimode SC, 2 km), EIS6-100T/FT (multimode ST, 2 km), or EIS6-100T/FCS (single-mode SC, 15 km). All EIS6 variants are also UL 864 Recognized Components.

How does the AC + battery backup mode work?

The EIS8-100T can operate from AC power with a backup battery providing power if the AC source fails. The 4-pin power connector accepts both AC inputs and a backup battery terminal. Important: the EIS8-100T does NOT charge the battery — you must provide separate battery charging provisions in the system design. This is typical for fire alarm system architectures where a dedicated charger and battery monitor handle the battery health, and the switch simply consumes power from whichever source is available.

Can the EIS8-100T be installed in a UL 508A control panel as well?

Yes. In addition to the UL 864 Recognized Component status for fire alarm systems, the EIS8-100T is UL 508 Listed and c-UL Listed for Industrial Control Equipment. UL 508-listed components are directly acceptable for use in UL 508A panels when supplied from a Class 2 limited-energy source per the panel's circuit requirements.

Does the switch require any configuration?

No. The EIS8-100T is fully unmanaged and plug-and-play. It has no IP address, no web interface, and no firmware to set up. Each port auto-negotiates speed (10/100) and duplex (half/full). Auto-MDIX accepts straight-through or crossover cables on copper ports.

Can I mount it on a DIN-rail or directly to a panel?

Both. The EIS8-100T ships with a TS-35 (35 mm) DIN-rail clip pre-attached. To switch to panel mount, remove the clip, extend the integrated mounting brackets at top and bottom, and secure with two #8 pan-head screws (not included). This single-SKU dual-mount design simplifies inventory and field changes. Note: with brackets extended, the unit is approximately 7.5 inches tall; with brackets retracted (DIN mode), it is approximately 6.1 inches tall.

What do the front-panel LEDs indicate?

A single PWR LED (green) glows when proper power is applied to the switch. Each port has two LEDs: a LINK LED (green) that glows solid when a valid Ethernet link is established and flashes during data transfer, and an HS LED (yellow) that glows when the port is operating at 100 Mbps.

Sub-Category:
Smoke and Fire UL 864