Dwyer 2000-10CM : Magnehelic Differential Pressure Gage, Range 0-10 cm, 4" (101.6 mm) Diameter Dial Face, +/-2% Accuracy

Dwyer

MSRP: $126.85
$105.54
(You save $21.31 )
(No reviews yet) Write a Review
SKU:
2000-10CM
Condition:
New
Availability:
Less Than 1 Week
Adding to cart… The item has been added

Dwyer 2000-10CM : Magnehelic Differential Pressure Gage, Range 0-10 cm, 4" (101.6 mm) Diameter Dial Face, +/-2% Accuracy

The Series 2000 Magnehelic Differential Pressure Gauge is the industry’s most trusted and widely used low-pressure gauge, offering high accuracy, durability, and ease of installation. This patented differential pressure gauge is designed to measure air and non-combustible gases, ensuring precision in HVAC systems, clean rooms, hospital isolation rooms, and industrial applications.

Key Benefits & Features

  • Precision Measurement: Frictionless Magnehelic® movement ensures highly accurate readings for positive, negative, or differential pressure
  • Durability & Longevity: Shock, vibration, and overpressure-resistant with a 5-year warranty for long service life.
  • Installation Flexibility: IP67-rated weatherproof housing with diecast aluminum construction, ideal for harsh environments.
  • Low Maintenance: No external power required for operation, reducing system costs and complexity.
  • Wide Application Range: Suitable for monitoring air filters, ducts, clean rooms, hospitals, dust collectors, fan pressure, fume exhaust systems, and more.
  • Easy-to-Read Dial: The 4" dial face with a clear acrylic cover provides undistorted viewing, even from a distance.

Applications of the Series 2000 Magnehelic Gauge

  • Filter Monitoring in HVAC Systems: Quickly detects pressure drops across filters, signaling when maintenance or replacement is needed.
  • Industrial Dust Collectors: Monitors pressure differentials to determine when filter cleaning or replacement is necessary, preventing system failures.
  • Hospital Isolation Rooms: Maintains proper negative pressure to prevent pathogen spread in medical facilities.
  • Clean Rooms & Laboratory Environments: Ensures required positive pressure conditions for contamination control.
  • Duct & Room Pressure Monitoring: Measures building pressurization and airflow to maintain energy efficiency and regulatory compliance.
  • Blower & Fan Performance: Detects inefficiencies in blower and fan systems, allowing proactive maintenance.

Technical Specifications

Note: For applications with high cycle rate within gage total pressure rating, next higher rating is recommended. See Options page.

Service Media: Air and non-combustible, compatible gases (natural gas option available). Note: May be used with hydrogen. Order a
Buna-N diaphragm. Pressures must be less than 35 psi.
Wetted Materials Consult factory.
Housing Die cast aluminum case and bezel, with acrylic cover, exterior finish is coated gray to withstand 168 hour salt spray corrosion
test.
Accuracy ±2% of FS (±3% on -0, -100 Pa, -125 PA, -10 mm and ±4% on -00, -60 Pa, -6 mm ranges), throughout range at 70°F
(21.1°C).
Pressure Limits 20 in Hg to 15 psig (-0.677 bar to 1.034 bar); MP option; 35 psig (2.41 bar), HP option; 80 psig (5.52 bar).
Enclosure Rating IP67.
Overpressure Relief plug opens at approximately 25 psig (1.72 bar), standard gages only. See Overpressure Protection note on catalog
page.
Temperature Limits 20 to 140°F (-6.67 to 60°C). -20°F (-28°C) with low temperature option.
Size 4″ (101.6 mm) diameter dial face.
Mounting Orientation Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections 1/8″ female NPT duplicate high and low pressure taps - one pair side and one pair back.
Weight 1 lb 2 oz (510 g); MP and HP 2 lb 2 oz (963 g).
Standard Accessories Two 1/8″ NPT plugs for duplicate pressure taps, two 1/8″ pipe thread to rubber tubing adapters and three flush mounting
adapters with screws. (Mounting and snap ring retainer substituted for three adapters in MP and HP gage accessories).
Compliance Meets the technical requirements of EU Directive 2011/65/EU (RoHS II)

 