Dwyer AVLV-2DA1-LCD : Duct Mount Low Air Velocity Transmitter, 2% Accuracy, Field selectable 100, 200, 300, 400 FPM, 4-20 mA, 0-5 VC, 0-10 VDC Outputs, LCD Display, 5 Year Warranty

Dwyer

MSRP: $338.30
$321.39
(You save $16.91 )
(No reviews yet) Write a Review
SKU:
AVLV-2DA1-LCD
Condition:
New
Availability:
Ships in 7-10 Days
Adding to cart… The item has been added

Dwyer AVLV-2DA1-LCD : Duct Mount Low Air Velocity Transmitter, 2% Accuracy, Field selectable 100, 200, 300, 400 FPM, 4-20 mA, 0-5 VC, 0-10 VDC Outputs, LCD Display, 5 Year Warranty

The Series AVLV Air Velocity Transmitter offers precise measurement of air velocity or volumetric flow in both imperial and metric units. Featuring simultaneous current and voltage outputs, it ensures compatibility with a wide range of monitoring equipment. The device's output range, units, and 0-5/10 VDC or 4-20 mA signals are easily configurable through local DIP switches. Users can monitor and configure process values conveniently with the optional integral display or a portable remote tool.

The transmitter includes low-velocity ranges to meet diverse application needs. Designed for high accuracy and lower ranges, these units are ideal for quality-sensitive environments, such as the pharmaceutical industry.

Product Applications:

  • VAV systems
  • Building ducts
  • Clean room systems

Specifications: 

Service: Clean air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Range: 100, 200, 300, 400 FPM (0.5, 1, 1.5, 2 m/s); field selectable.
Temperature Limits: 32 to 122°F (0 to 50°C).
Power Requirements: 24 VDC ±20% or 24 VAC ±20%.
Humidity Limits: 5 to 95% RH, non-condensing.
Output Signal: 4-20 mA, 0-5 VDC, 0-10 VDC.
Response Time (90%): 4 s, typical; 1 s at constant temperature.
Zero and Span Adjustments: Digital push buttons.
Output Load Resistance:
Current output: 0 to 1100 Ω max.; Voltage output: Minimum load resistance 1 kΩ.
Current Consumption: 60 mA max.
Display (Optional): 5 digit LCD (optional).
Electrical Connections:
Analog: Power and output: four wire removable European style terminal block for 16 to 26 AWG
Device Load: 1/8 unit load.
Electrical Entry: 1/2˝ NPS thread. Accessory: Cable gland for 5 to 10 mm diameter cable, A-151.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation:
Flow direction must be parallel to the sensor tip.
Weight: 6.0 oz (160 g).
Compliance:
BTL, CE.

 

Datasheets

pdf logo Dwyer AVLV Series | Low Air Velocity Transmitter | Data Sheet
pdf logo Dwyer AVLV Series | Low Air Velocity Transmitter | Catalog Pages
pdf logo Dwyer AVLV Series | Installation and Operating Instructions