Skip to main content

Dwyer AVUL-5DB1-LCD : Duct Mount Air Velocity Transmitter, 5% Accuracy, Field selectable 1000, 2000, 3000, 4000 FPM, BACnet MS/TP and 4-20 mA, 0-5 VC, 0-10 VDC Outputs, LCD Display 5 Year Warranty

Dwyer

MSRP: $368.40
$349.98
(You save $18.42 )
(No reviews yet) Write a Review
SKU:
AVUL-5DB1-LCD
Condition:
New
Availability:
Ships in 7-10 Days
Adding to cart… The item has been added

Dwyer AVUL-5DB1-LCD : Duct Mount Air Velocity Transmitter, 5% Accuracy, Field selectable 1000, 2000, 3000, 4000 FPM, BACnet MS/TP and 4-20 mA, 0-5 VC, 0-10 VDC Outputs, LCD Display 5 Year Warranty

The Series AVUL Air Velocity Transmitters deliver precise and efficient measurement of air velocity or volumetric flow, available in both imperial and metric units. Each model features simultaneous current and voltage outputs, ensuring seamless integration with a variety of monitoring systems. Configuration of output ranges, units, and 0 to 5/10 VDC or 4-20 mA output is made simple using onboard DIP switches. With BACnet MS/TP communication protocols, these transmitters support daisy-chaining and provide access to comprehensive data, including velocity, flow, and air temperature.

Features

  • Minimal preventative maintenance as the sensing element is covered with an engineered protective coating.
  • Easy field setup via the onboard DIP switches for range and unit configuration.

Product Applications

  • Variable Air Volume (VAV) systems
  • Building duct monitoring

Specifications: 

Service: Clean air and non-combustible, compatible gases.
Range: 1000, 2000, 3000, 4000 FPM (5, 10, 15, 20 m/s); Field selectable.
Accuracy: ±(5% of reading +0.2 m/s)
Temperature Limits: 32 to 122°F (0 to 50°C).
Power Requirements: 24 VDC ±20% or 24 VAC ±20%.
Humidity Limits: 5 to 95% RH, non-condensing.
Output Signal: 4-20 mA, 0-5 VC, 0-10 VDC.
Response Time (90%): 10 s (typ).
Zero and Span Adjustments: Digital push buttons.
Current Consumption: 60 mA max.
Display (Optional): 5 digit LCD.
Communication (Optional): Connections: BACnet MS/TP: 3-wire removable European style terminal block for 16 to 26
AWG; Supported baud rates: 9600, 19200, 38400, 57600, 76800, 115200.
Device Load: 1/8 unit load.
Electrical Entry: 1/2˝ NPS thread; Accessory (A-151): Cable gland for 5 to 10 mm diameter cable.
Enclosure Rating: NEMA 4X (IP66).
Weight: 6.0 oz (160 g).
Compliance:
CE.

 

Datasheets

pdf logo Dwyer AVUL Series | Air Velocity Transmitter | Data Sheet
pdf logo Dwyer AVUL Series | Air Velocity Transmitter | Catalog Page
pdf logo Dwyer AVUL Series | BACnet Communication | Installation and Operating Instructions