null Skip to main content

Dwyer DM-1109 : DigiMag Digital Differential Pressure Gage, Range 0 to 15 in w.c., 4-Digit LCD, NEMA 4X (IP66)

Dwyer

MSRP: $272.90
Your Price:  $217.30
(You save $55.60 )
(No reviews yet) Write a Review
SKU:
DM-1109
Condition:
New
Availability:
0 In Stock | Lead Time: 4 weeks
Adding to cart… The item has been added
The Dwyer DM-1109 is a Series DM-1000 DigiMag digital differential pressure gage with a range of 0 to 15 in w.c. (0 to 3738 Pa). It is rated +/-1% F.S. with 0.010 in w.c. resolution on a 4-digit LCD, runs on a 9V battery or 9-24 VDC line power, and fits a standard Magnehelic gage cut-out with a NEMA 4X (IP66) rating.
Pressure Range0 to 15 in w.c.
Accuracy+/-1% F.S.
Resolution0.010 in w.c.
Display4-Digit LCD
EnclosureNEMA 4X (IP66)
Power9V Battery or 9-24 VDC

Overview

The Series DM-1000 DigiMag replaces an analog mechanical gage with a field-programmable digital instrument. It can be programmed in 8 engineering units plus percent of full scale, so units can be changed on site without calculating conversions. All models are factory calibrated to a specific range.

Four menus reached from the MENU key give access to security level, engineering units, filter set point, peak and valley process readings, digital damping for erratic processes, display update rate to conserve battery life, and zero and span field calibration.

A filter set point can be entered so the display blinks when the reading crosses it, alerting the user that a maintenance action needs to occur. Power is flexible: the gage runs on 9-24 VDC line power or a 9V battery, and when both are connected the battery acts as backup if line power is lost or interrupted.

Specifications

ModelDM-1109
Range0 to 15 in w.c.
Resolution0.010 in w.c.
ServiceAir and non-combustible, compatible gases.
Wetted MaterialsConsult factory.
Housing MaterialsGlass filled plastic.
Accuracy+/-1% F.S. including linearity, hysteresis and repeatability.
Long Term Stability+/-1% F.S. per year.
Thermal Effect+/-0.05% F.S./F typical.
Temperature Limits0 to 140 F (-18 to 60 C).
Compensated Temperature Limits32 to 122 F (0 to 50 C).
Pressure Limit11 psi (75 kPa)
Display4-digit LCD, digits 0.60 in H x 0.33 in W.
Display UpdateSelectable from 1 second to 10 minutes, or update only on button push.
Selectable Engineering Unitsin w.c., psi, kPa, Pa, mm w.c., mBar, in Hg, mm Hg, and % of full scale (0-100%).
Digital DampingAdjustable 1 to 15.
Power Requirements9V battery or external power supply 9-24 VDC. Battery included, shipped not connected.
Type of Battery9V alkaline (Duracell PC 1604 or equivalent).
Battery Service Life150 hours typical at 1 second display update; 9 months typical at 10 minute display update; 1.5 years typical with display update disabled. Up to four times longer with a lithium ULTRALIFE U9VL-J.
Current Consumption5 mA maximum.
Electrical ConnectionsRemovable terminal block for 16 to 26 AWG.
Electrical EntryCable gland for 0.114 to 0.250 in (2.9 to 6.4 mm) diameter cable.
Process Connections1/8 in (3 mm) ID tubing.
Tubing Size3/16 in (4.8 mm) I.D. x 5/16 in (7.9 mm) O.D. flexible PVC tubing.
Panel Cut-Out4-9/16 in diameter panel opening; vertical mounting position required.
Enclosure RatingNEMA 4X (IP66).
Size5 in (127 mm) O.D. front face; 2.33 in overall depth (dimensional drawing).
Weight1.18 lb (535 g).
Agency ApprovalsCE; EN 61326-1 [Immunity Test Requirement for Industrial Environments] to IEC 61000-3-2, 61000-3-3, 61000-4-2, 61000-4-3, 61000-4-4, 61000-4-5, 61000-4-6 and 61000-4-11.

Range in Selectable Engineering Units

in w.c.PakPambarmm w.c.psiin Hgmm Hg
15.0037383.73837.38381.00.5431.10428.02

Full-scale value of this model expressed in each selectable engineering unit. Units marked with a dash on the Dwyer model chart are not offered for this range and are omitted.

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressure in ducts or buildings
  • Room pressurization monitoring

In the Box

  • Mounting lugs - 3
  • 6-20 x 2-1/2 in screws - 3
  • 4-20 x 3/8 in screws - 3
  • Cable gland - 1
  • 9V alkaline battery - 1 (shipped not connected)

Optional Accessories

A-2864-1/2 in gage panel mounting flange
A-300Flat flush mounting bracket
A-480Plastic static pressure tip
A-4894 in straight static pressure tip with flange

Add the -NIST suffix when ordering for a NIST traceable calibration certificate (example: DM-1109-NIST).

Documentation

Frequently Asked Questions

What is the pressure range of the Dwyer DM-1109?

The DM-1109 covers 0 to 15 in w.c. (0 to 3738 Pa), with 0.010 in w.c. resolution.

Can the Dwyer DM-1109 measure air velocity or flow?

No. Velocity and flow operation is not available on DM-1100 models. For air velocity or volumetric flow, use the corresponding DM-1200 model.

How accurate is the Dwyer DM-1109?

It is rated +/-1% F.S. including linearity, hysteresis and repeatability. Dwyer specifies +/-1% F.S. on ranges down to 2 in w.c. and +/-2% F.S. on the 1, 0.5 and 0.25 in w.c. ranges.

What units can the Dwyer DM-1109 display?

Eight engineering units plus percent of full scale: in w.c., psi, kPa, Pa, mm w.c., mBar, in Hg and mm Hg. Units are changed in the field from the OPEr menu, so no conversion arithmetic is needed.

How is the Dwyer DM-1109 powered?

A 9V alkaline battery or an external 9-24 VDC supply. The battery is included but shipped not connected. If both are connected the battery acts as backup when line power is lost.

How long does the battery last?

About 150 hours at a 1 second display update, about 9 months at a 10 minute update, and about 1.5 years with the display update disabled. A lithium ULTRALIFE U9VL-J can extend that up to four times.

Does the Dwyer DM-1109 fit a Magnehelic gage cut-out?

Yes. The gage is a 5 in O.D. front face and installs in a 4-9/16 in diameter panel opening, the same cut-out used by the analog Magnehelic gage. A vertical mounting position is required because that is the position the gage is calibrated in at the factory.

Can the Dwyer DM-1109 alert on a dirty filter?

Yes. A filter set point can be entered and the filter type set to HIGH or LOW, and the display blinks when the reading passes that set point. In 10 minute or on-touch display modes the LCD shows ALAr instead.

Specifications on this page are taken from Dwyer Series DM-1000 catalog page 25 and from Bulletin P-DM-1100, FR# 443779-00 Rev. 6 (2/19). One discrepancy is unresolved in Dwyer's own literature: the specification panel lists process connections as 1/8 in (3 mm) ID tubing, while the installation section states the integral connections are sized for 3/16 in (4.8 mm) I.D. x 5/16 in (7.9 mm) O.D. flexible PVC tubing. Both figures are shown above as printed; confirm with Dwyer before specifying tubing. Reviewed August 2026.

1 Year
Series:
DM-1000 DigiMag
Model Family:
DM-1100
Measurement Type:
Differential Pressure
Range Type:
Unidirectional
Pressure Range:
0 to 15 in w.c.
Accuracy:
+/-1% F.S.
Display:
4-Digit LCD
Enclosure Rating:
NEMA 4X IP66
Power Source:
9V Battery or 9-24 VDC
Process Connection:
Integral Tubing Ports
Media:
Air and Compatible Non-Combustible Gases