Skip to main content

Dwyer GSTC-N-LCD : Wall Mount Nitrogen Dioxide Transmitter, 10 PPM, BACnet MS/TP, Modbus RTU, or Modbus ASCII (switch selectable) Communication Protocol, LCD Display, 5-Year Warranty

Dwyer

MSRP: $504.65
$479.42
(You save $25.23 )
(No reviews yet) Write a Review
SKU:
GSTC-N-LCD
Condition:
New
Availability:
Ships in 1 Week
Adding to cart… The item has been added

Dwyer GSTC-N-LCD : Wall Mount Nitrogen Dioxide Transmitter, 10 PPM, BACnet MS/TP, Modbus RTU, or Modbus ASCII (switch selectable) Communication Protocol, LCD Display, 5-Year Warranty

The Series GSTC Carbon Monoxide Transmitter is designed to monitor gas concentrations in underground parking garages and loading docks, effectively measuring the exhaust from gasoline engines. Compatible with BACnet or Modbus® communication protocols, it integrates seamlessly with most building management controllers. For enhanced accuracy, the transmitter supports field calibration using the A-449 remote LCD display. Additionally, the display notifies users when the sensor reaches the end of its life and requires replacement.

Benefits/Features

  • Easy Maintenance: Industrial-grade, replaceable electrochemical sensors with a typical lifespan of two years.
  • Inventory Efficiency: Field-selectable outputs reduce the need for multiple units.

Applications

  • Ventilation monitoring in garages or loading docks.
  • Air quality monitoring in mechanical rooms.

Specifications: 

Sensor: Field replaceable electrochemical, 2 years typical lifespan.
Range: NO2: 10 PPM
Output Drift: <5% per year in air.
Coverage Area: 5000 to 7500 sq ft typical.
Accuracy: NO2: 3% FS, at the time of calibration.
Resolution: NO2: 0.1 PPM.
Temperature Limits: -4 to 122°F (-20 to 50°C).
Storage Temperature: For best sensor life, 32 to 68°F (0 to 20°C).
Humidity Limits: 15 to 90% RH constant; 0 to 99% RH intermittent.
Response Time: <25 s to 90% NO2
Span and Zero Adjustment: GSTC models: Zero only via BACnet or Modbus® communication protocol.
Housing: UV resistant glass filled polycarbonate.
Output Signals: GSTC: BACnet MS/TP, Modbus® RTU, or Modbus® ASCII (switch selectable) communication protocol.
Power Requirements: GSTC: 10-36 VDC or isolated 21.6-33 VAC, 5.7 mA @ 24 VDC.
Electrical Connection: Removable terminal block, knockouts for conduit fitting.
Calibration: Via onboard push-buttons (LCD model only) or using optional A-449
display. Span gas concentration is field selectable.
Enclosure Rating: IP64.
Weight: 1 lb (0.45 kg).
Compliance: CE.

 

Datasheets

pdf logo Dwyer GSTC Series | Carbon Monoxide Data Sheet
pdf logo Dwyer GSTC Series | Carbon Monoxide Catalog Pages
Enclosure Style:
Wall
Gas Element:
Nitrogen Dioxide
Analog Output:
None
Relay Output:
None
Communication:
BACnet/Modbus
Display: