Motor rating1/4 HP
Input supplySingle-phase, 200 to 240 V
Rated output current1.5 A
EnclosureIP20, UL open type
Braking transistorNot available
CommunicationRS-485 Modbus RTU
The Fuji Electric FRN0002C2S-7U is a FRENIC-Mini (C2) compact variable frequency drive rated 1/4 HP with a single-phase, 200 to 240 v, 50/60 hz and a rated output current of 1.5 A.

The FRN0002C2S-7U drives a 1/4 HP four-pole standard motor from a Single-phase, 200 to 240 V, 50/60 Hz supply. Control is by V/f, slip compensation, automatic torque boost or dynamic torque vector control, with an automatic energy-saving function and a process PID regulator built in. It takes a single-phase supply and delivers a three-phase output to the motor, so a three-phase motor runs from a single-phase service. Frequency is set from the built-in volume, a 0 to +10 V DC or 4 to 20 mA DC analog input, the keypad, 16 preset steps or RS-485.

Best for

  • Conveyors, fans, pumps, centrifugal separators and food processing machines
  • Panels where depth matters: the frame measures 80 x 120 x 80 mm (3.15 x 4.72 x 3.15 inches) W x H x D
  • Sites with only a 230 V single-phase service that need to run a three-phase motor
  • Small loads that stop on their own: this model has no braking transistor, so an external braking resistor cannot be used
  • Quiet or dusty locations: this model is natural cooled with no cooling fan

Warranty

3-year standard warranty from the shipping date for product installed in the USA. Product installed outside the USA carries a 2-year warranty.

Key features

Dynamic torque vector control

Delivers 150% or more starting torque running at 1 Hz with slip compensation and auto torque boost active, for conveyors and high-inertia loads.

RS-485 built in

RJ-45 connector on the unit with Modbus RTU, Fuji dedicated inverter protocol, dedicated keypad protocol and SX protocol for PC loader, plus a terminator ON/OFF switch.

Process PID regulator

Controls temperature, pressure or flow without an external controller, with a low liquid level stop function and integration reset and hold.

Sensorless synchronous motor drive

Sensorless magnetic positioning drives a synchronous motor over a speed control range of 10% of base frequency and up, on ROM version 0500 or later.

16-speed operation

Sixteen preset frequencies are selected from the five programmable digital inputs using SS1, SS2, SS4 and SS8.

Natural cooling

This model is natural cooled, so there is no cooling fan in the drive to service.

Technical specifications

Inverter typeFRN0002C2S-7U
SeriesFRENIC-Mini (C2), standard model
Nominal applied motor1/4 HP (Fuji four-pole standard motor)
Rated capacity0.57 kVA
Input phases, voltage, frequencySingle-phase, 200 to 240 V, 50/60 Hz
Voltage and frequency variationVoltage: +10 to -10%, Frequency: +5 to -5%
Rated output voltageThree-phase 200 to 240 V (with AVR)
Output voltage setting range80 to 240 V settable at base frequency and at maximum output frequency
Rated output current1.5 A
Derated continuous current1.4 A
Overload capability150% of rated current for 1 min; 150% of rated current for 1 min or 200% of rated current for 0.5 s when the rated current in parentheses applies
Rated frequency50, 60 Hz
Input rated current with DC reactor2.0 A
Input rated current without DC reactor3.3 A
Required power supply capacity0.4 kVA (with DC reactor)
Braking torque150% average braking torque decelerating from 60 Hz with AVR control OFF
Braking transistorNot available on this model
Cooling methodNatural cooling
Weight / mass0.6 kg (1.3 lbs)
External dimensions80 x 120 x 80 mm (3.15 x 4.72 x 3.15 inches) W x H x D
EnclosureIP20 (IEC 60529:1989), UL open type (UL50)
Applicable safety standardsUL508C, EN 61800-5-1:2007
Maximum frequency25 to 400 Hz
Base frequency25 to 400 Hz
Starting frequency0.1 to 60.0 Hz
Carrier frequency0.75 to 16 kHz
Frequency setting resolutionAnalog 1/1000 of maximum frequency; keypad 0.01 Hz at 99.99 Hz or less, 0.1 Hz from 100.0 to 400.0 Hz; link 1/20000 of maximum frequency or 0.01 Hz fixed
Frequency accuracyAnalog within ± 2% at 25°C (77°F); keypad within ± 0.01% at 25°C (77°F)
Control method (induction motor)V/f control, slip compensation, automatic torque boost, dynamic torque vector control, automatic energy-saving function
Control method (synchronous motor)Sensorless magnetic positioning, speed control range 10% of base frequency and up (ROM version 0500 or later)
Starting torque150% or more running at 1 Hz with slip compensation and auto torque boost active (induction motor drive only)
Torque boostAutomatic torque boost for constant torque loads; manual torque boost settable 0.0 to 20.0%
Acceleration / deceleration time0.00 to 3600 s, two independent settings switchable while running; linear, S-curve weak, S-curve strong or non-linear pattern
Multistep frequency16 steps (step 0 to 15) selected by SS1, SS2, SS4 and SS8
Digital inputs5 programmable inputs: X1, X2, X3, FWD and REV. Sink or source selected with the built-in switches on the unit
Analog inputs2 inputs: terminal 12 accepts 0 to +10 V DC for 0 to 100%; terminal C1 accepts +4 to +20 mA DC (or 0 to +20 mA DC) for 0 to 100%. Either can be used as PID process command or feedback
Frequency setting potentiometerBuilt-in volume. Terminal 13 supplies DC 10 V for an external 1 to 5 kΩ potentiometer
Transistor output1 output (Y1). Short circuit when ON signal is output, or open circuit when ON signal is output. Max 27 V DC, max 50 mA, leak current 0.1 mA max, ON voltage within 2 V at 50 mA
Alarm relay output1 output (30A, 30B, 30C). No-voltage contact signal (1c) when the inverter stops on an alarm. Alarm output can be switched between excitation operation and non-excitation operation. Contact rating AC 250 V 0.3 A cosφ = 0.3, DC 48 V 0.5 A
Analog output1 output (FMA). DC voltage 0 to 10 V, gain settable between 0 and 300%. Selectable monitor: output frequency before or after slip compensation, output current, output voltage, input power, PID feedback value, DC link circuit voltage, PID command, PID output, analog output test
Serial communicationBuilt-in RJ-45 connector, RS-485. Selectable protocol: dedicated keypad protocol, Modbus RTU, Fuji dedicated inverter protocol, or SX protocol for PC loader. Includes terminator ON/OFF switch
PLC terminal+24 V (22 to 27 V), max 50 mA
PID controlProcess PID regulator. Command from keypad, analog input terminal C1 or RS-485; feedback from analog input terminal C1. Low liquid level stop function, forward/reverse switching, integration reset and hold
DC injection brakingStarting frequency 0.0 to 60.0 Hz, braking time 0.0 to 30.0 s, braking level 0 to 100% (induction motor drive only)
Momentary power failureProtective function stops the inverter on a momentary power failure of 15 ms or more; restart selectable
Installation locationIndoors, free of corrosive gases, flammable gases, dust and oil mist, contamination level 2 (IEC 60664-1: 2007). Keep out of direct sunlight
Ambient temperature−10°C (14°F) to +50°C (122°F) open type (IP20); −10°C (14°F) to +40°C (104°F) with side-by-side mounting or with a NEMA 1 kit fitted
RoHSYes
Ambient humidity5 to 95% RH (no condensation)
Altitude1000 m (3300 ft) or less with no output derating
Vibration3 mm (0.12 inch) vibration width from 2 to less than 9 Hz; 9.8 m/s² from 9 to less than 20 Hz; 2 m/s² from 20 to less than 55 Hz; 1 m/s² from 55 to less than 200 Hz

Specifications on this page are taken from Fuji Electric FRENIC-Mini Series catalog, 24A1-E-0011e, printed pages 6, 7, 9 to 14 and 16. Ambient temperature derating and RoHS status are taken from Fuji Electric Corp. of America datasheet FECA-DS-101b. Verified September 2026.

Matched options

OptionPart numberNote
NEMA 1 kitNEMA1-C2-101Not applicable to the EMC filter built-in type or to inverters of 5.5 kW or above
DIN rail mounting baseRMA-C1-0.75Not suitable for inverters of 5.5 kW (7.5 HP) or above

Specifications on this page are taken from Fuji Electric FRENIC-Mini Series catalog, 24A1-E-0011e, printed pages 19, 20 and 21. Verified September 2026.

Documentation

Frequently asked questions

What motor can the FRN0002C2S-7U run?
It is rated for a 1/4 HP Fuji four-pole standard motor, with a rated capacity of 0.57 kVA and a rated output current of 1.5 A.
What input power does the FRN0002C2S-7U need?
Single-phase, 200 to 240 V, 50/60 Hz. The permitted variation is voltage: +10 to -10%, frequency: +5 to -5%.
What is the overload rating of the FRN0002C2S-7U?
150% of rated current for 1 min; 150% of rated current for 1 min or 200% of rated current for 0.5 s when the rated current in parentheses applies, on a rated output current of 1.5 A.
Does the FRN0002C2S-7U support Modbus RTU?
Yes. RS-485 is built in on an RJ-45 connector and Modbus RTU is one of the selectable protocols, alongside the Fuji dedicated inverter protocol, the dedicated keypad protocol and SX protocol for PC loader.
Can the FRN0002C2S-7U run a three-phase motor?
Yes. The input is single-phase, 200 to 240 v, 50/60 hz and the rated output voltage is three-phase 200 to 240 v (with avr).
Can a braking resistor be used with the FRN0002C2S-7U?
No. This model has no braking transistor, so an external braking resistor cannot be operated with it.
Which NEMA 1 kit fits the FRN0002C2S-7U?
The NEMA1-C2-101. Mounting the kit brings the inverter enclosure into compliance with the NEMA1 Standard (UL TYPE1 certified).
What temperature and humidity can the FRN0002C2S-7U run in?
−10°C (14°F) to +50°C (122°F) open type (IP20); −10°C (14°F) to +40°C (104°F) with side-by-side mounting or with a NEMA 1 kit fitted. Humidity is 5 to 95% RH with no condensation, at 1000 m (3300 ft) or less without derating.
Series:
FRENIC-Mini (C2)
Phase:
1-Phase
Voltage:
230VAC
Power Rating:
1/4 HP
Enclosure:
IP20
Safe Torque Off (STO):
No
Communication:
Modbus RTU
Warranty:
3-Year Standard Warranty
Software Included:
FRENIC-Loader
Braking Transistor:
Not Available