The Fuji Electric FRN0037E3S-4G is a FRENIC-Ace E3 Basic type variable frequency drive for a three-phase 380 to 480 V supply, rated 11 kW (15 HP) at 24 A on the HHD specification and 15 kW (20 HP) at 35 A on the HND specification.
It is the 0037 capacity code in the three-phase 400 v FRENIC-Ace E3 lineup, supplied as the S (Basic type) enclosure with global English documentation. The drive uses fan cooling, is built to IP20 enclosed type and UL open type, and weighs 5.2 kg (11 lbs). A braking transistor is built in, and a DC reactor and braking resistor are available as options.
Specifications on this page are taken from the Fuji Electric FRENIC-Ace Series catalog, revision 24A1-E-0174c.
Best For
- Panel builders fitting a 15 HP class three-phase 400 v drive on conveyors, fans and pumps
- OEM machines that need one drive to cover both a 11 kW HHD and a 15 kW HND selection
- Applications with frequent stops or high-inertia loads where an external braking resistor will be fitted
- Installations on a 3-Phase 380 to 480 V supply with an in-panel, IP20 mounting location
Warranty
Fuji Electric warrants this product for 1 year from the date of purchase or 24 months from the manufacturing date stamped on the nameplate, whichever comes first. Parts restored by Fuji Electric's Service Department carry a 6 month warranty from the date repairs are completed. The warranty does not cover breakdowns caused by use outside the conditions stated in the catalog or operation manual, by modification or repair by a third party, or by events outside Fuji Electric's responsibility.
Key Features
4 duty ratings in one drive
Selectable HHD / HND / HD / ND ratings let one drive cover a 11 kW (15 HP) HHD load at 24 A or a 15 kW (20 HP) HND load at 35 A.
Built-in braking transistor
A braking transistor is built in. Adding an optional braking resistor rated 40Ω minimum raises braking capability for frequent stops and high-inertia loads.
Output to 599 Hz
Maximum output frequency is 5 to 599 Hz, with base frequency variable across the same range for high-speed spindle and machine-tool work.
Carrier frequency up to 16 kHz
Carrier frequency is variable from 0.75 to 16 kHz on the HHD specification, so motor noise can be traded against thermal headroom.
Fine frequency resolution
Analog setting resolution is 1/3000 of maximum output frequency. Digital setting is 0.01 Hz below 99.99 Hz and 0.1 Hz from 100.0 to 599.0 Hz.
Fan cooled in an IP20 enclosure
This capacity uses fan cooling in an IP20 enclosed, UL open type housing for in-panel mounting. Unit weight is 5.2 kg (11 lbs).
Technical Specifications
| Type | FRN0037E3S-4G |
|---|---|
| Series | FRENIC-Ace E3, Basic type |
| Standard applicable motor, HHD | 11 kW (15 HP) |
| Standard applicable motor, HND | 15 kW (20 HP) |
| Standard applicable motor, HD | 15 kW (20 HP) |
| Standard applicable motor, ND | 18.5 kW (25 HP) |
| Rated capacity, HHD | 18 kVA |
| Rated capacity, HND | 27 kVA |
| Rated capacity, HD | 24 kVA |
| Rated capacity, ND | 28 kVA |
Source: FRENIC-Ace Series catalog 24A1-E-0174c, p. 17, 20.
| Rated output voltage | Three-phase 400 to 480 V (with AVR function) |
|---|---|
| Rated output current, HHD | 24 A |
| Rated output current, HND | 35 A |
| Rated output current, HD | 35 A |
| Rated output current, ND | 37 A |
| Overload current rating, HHD | 150% for 1 minute, 200% for 0.5 seconds |
| Overload current rating, HND | 120% for 1 minute |
| Overload current rating, HD | 150% for 1 minute |
| Overload current rating, ND | 120% for 1 minute |
| Rated frequency | 50 / 60 Hz |
| Maximum output frequency | 5 to 599 Hz |
| Base frequency | 5 to 599 Hz variable |
| Starting frequency | 0.1 to 60.0 Hz variable (0.0 Hz under vector control) |
| Carrier frequency, HHD | 0.75 to 16 kHz variable |
| Carrier frequency, HND | 0.75 to 16 kHz variable |
| Carrier frequency, HD | 0.75 to 16 kHz variable |
| Carrier frequency, ND | 0.75 to 10 kHz variable |
Source: FRENIC-Ace Series catalog 24A1-E-0174c, p. 20, 26.
| Input voltage and frequency | Three-phase 380 to 480 V, 50/60 Hz |
|---|---|
| Voltage and frequency fluctuation | Voltage: +10 to -15% (interphase unbalance ratio: 2% or less), Frequency: +5 to -5 % |
| Rated input current with DCR, HHD | 21.1 A |
| Rated input current with DCR, HND | 28.8 A |
| Rated input current with DCR, HD | 28.8 A |
| Rated input current with DCR, ND | 35.5 A |
| Rated input current without DCR, HHD | 33 A |
| Rated input current without DCR, HND | 43.8 A |
| Rated input current without DCR, HD | 43.8 A |
| Rated input current without DCR, ND | 52.3 A |
| Required power supply capacity with DCR, HHD | 15 kVA |
| Required power supply capacity with DCR, HND | 20 kVA |
| Required power supply capacity with DCR, HD | 20 kVA |
| Required power supply capacity with DCR, ND | 25 kVA |
| Auxiliary control power supply input | Not provided on this type |
Source: FRENIC-Ace Series catalog 24A1-E-0174c, p. 20.
| Braking transistor | Built-in |
|---|---|
| Braking torque, HHD | 20% |
| Braking torque, HND | 15% |
| Braking torque, HD | 15% |
| Braking torque, ND | 12% |
| Connectable resistance value | 40Ω minimum |
| Braking resistor | Option |
| DC reactor (DCR) | Option |
Source: FRENIC-Ace Series catalog 24A1-E-0174c, p. 20.
| Ambient temperature, HHD | -10 to +55 °C [14 to 131 °F] (current derating necessary in +50 to +55 °C [122 to 131 °F] range) |
|---|---|
| Ambient temperature, HND | -10 to +55 °C [14 to 131 °F] (current derating necessary in +50 to +55 °C [122 to 131 °F] range) |
| Ambient temperature, HD | -10 to +50 °C [14 to 122 °F] (current derating necessary in +40 to +50 °C [104 to 122 °F] range) |
| Ambient temperature, ND | -10 to +50 °C [14 to 122 °F] (current derating necessary in +40 to +50 °C [104 to 122 °F] range) |
| Protective construction (IEC 60529) | IP20 enclosed type, UL open type |
| Cooling system | Fan cooling |
| Weight | 5.2 kg (11 lbs) |
Source: FRENIC-Ace Series catalog 24A1-E-0174c, p. 20.
| Carrier frequency derating | Output current derating is required when the carrier frequency (F26) is set at or above 8 kHz on the HHD and HND specifications for types FRN0002E3-4G to FRN0012E3-4G and 10 kHz for FRN0022E3-4G to FRN0059E3-4G, 6 kHz on the HND specification for FRN0072E3-4G, or 4 kHz on the HD and ND specifications for types FRN0002E3-4G to FRN0072E3-4G. |
|---|
Source: FRENIC-Ace Series catalog 24A1-E-0174c, p. 20.
| FRN | FRENIC series |
|---|---|
| 0037 | Applicable motor rating code: 11 kW HHD, 15 kW HND, 15 kW HD, 18.5 kW ND |
| E3 | Applicable area E (industrial, high performance, multiple functionality), development code 3 |
| S | Enclosure: Standard (Basic type) |
| 4 | Power supply: Three-phase 400 V |
| G | Destination and manual: Global / English |
Source: FRENIC-Ace Series catalog 24A1-E-0174c, p. 17.
Documentation
Frequently Asked Questions
What motor size does the Fuji FRN0037E3S-4G drive?
It is rated for a 11 kW (15 HP) motor on the HHD specification or a 15 kW (20 HP) motor on the HND specification or a 15 kW (20 HP) motor on the HD specification or a 18.5 kW (25 HP) motor on the ND specification. Always confirm the motor nameplate current against the drive's rated output current of 24 A HHD or 35 A HND or 35 A HD or 37 A ND.
What input supply does the FRN0037E3S-4G need?
Three-phase 380 to 480 V, 50/60 Hz. The catalog allows Voltage: +10 to -15% (interphase unbalance ratio: 2% or less), Frequency: +5 to -5 %.
Does the FRN0037E3S-4G have a built-in braking resistor?
No. The braking transistor is built in, but the braking resistor is an option. Connectable resistance for this model is 40Ω minimum.
What is the difference between HHD and HND and HD and ND on this drive?
HHD is the high carrier frequency, heavy load rating: 11 kW, 24 A, 150% for 1 minute, 200% for 0.5 seconds. HND is the high carrier frequency, general load rating: 15 kW, 35 A, 120% for 1 minute. HD is the heavy load rating: 15 kW, 35 A, 150% for 1 minute. ND is the general load rating: 18.5 kW, 37 A, 120% for 1 minute. The ratings also carry different ambient temperature limits and carrier frequency ranges.
What ambient temperature can the FRN0037E3S-4G run at?
On the HHD specification the range is -10 to +55 °C [14 to 131 °F] (current derating necessary in +50 to +55 °C [122 to 131 °F] range). On the HND specification the range is -10 to +55 °C [14 to 131 °F] (current derating necessary in +50 to +55 °C [122 to 131 °F] range).
What does the model number FRN0037E3S-4G mean?
FRN is the FRENIC series, 0037 is the applicable motor rating code, E3 is the industrial high-performance family and development code 3, S is the standard Basic type enclosure, 4 is a three-phase 400 v supply, and G is the global English destination code.