null Skip to main content

Fuji Electric OPC-115V : 115VAC Input/Output Interface Card, Remote Mount, for FRENIC-Mini (C2), 8 AC Inputs and 4 Relay Outputs

Fuji Electric

MSRP: $174.00
Your Price:  $121.80
(You save $52.20 )
(No reviews yet) Write a Review
SKU:
OPC-115V
Condition:
New
Adding to cart… The item has been added
Option typeI/O card
SeriesFRENIC-Mini (C2)
User side8 x 115 VAC in
Inverter side24 V DC
The Fuji Electric OPC-115V is the 115 VAC input/output interface card for the FRENIC-Mini (C2) series, converting 8 channels of 115 VAC user wiring to the inverter's 24 V DC control terminals.

The OPC-115V is a remote mount interface board that lets 115 VAC field wiring drive the inverter's 24 V DC digital inputs, and lets the inverter's transistor outputs switch 115 VAC or 24 V DC loads through relay contacts. It mounts on DIN rail or on a mounting plate.

Best for

  • Retrofits where the existing control wiring is 115 VAC line voltage
  • Panels that must keep 115 VAC control separate from the drive terminals
  • Machines where relay contacts are needed to switch a load from a drive output

Key features

115 VAC to 24 V DC input conversion

8 AC inputs at 115 VAC, 8 mA per channel, each driving a relay coil that presents a 24 V DC input to the inverter.

Relay outputs both sides

4 relay outputs on the user side at 250 VAC 5 A or 24 VDC 5 A per channel, and 8 relay outputs on the inverter side at 24 VDC 20 mA per channel.

LED status per channel

A status LED is provided for each relay: red on the AC side, green on the DC side.

Remote mount

Mounts on DIN rail or on a mounting plate, away from the inverter.

Technical specifications

TypeOPC-115V
Option classInput/output interface card
Compatible seriesFRENIC-Mini (C2)
User side digital inputs8 AC inputs, 115 VAC, 8 mA per channel
User side input parametersInput impedance 6.5 kΩ, minimum ON voltage 96 VAC, maximum OFF voltage 36 VAC, turn ON time 15 ms max, turn OFF time 10 ms max
User side digital outputs4 relay outputs, 250 VAC 5 A or 24 VDC 5 A per channel
Inverter side digital inputs4 DC inputs, 24 VDC, 12 mA per channel
Inverter side input parametersInput impedance 2.88 kΩ, minimum ON voltage 18 VDC, maximum OFF voltage 1.2 VDC, turn ON time 10 ms max, turn OFF time 5 ms max
Inverter side digital outputs8 relay outputs, 24 VDC 20 mA per channel
Operating and storage temperature0 to 60°C operating, −20 to 80°C storage
Operating humidity10% to 90% RH (no condensation)
Dimensions145 mm x 92 mm
MountingDIN rail or mounting plate
Country of originIndia

Specifications on this page are taken from the OPC-115V instruction sheet, QS-OPC-115-1010 Ver. 1.00, and from the Fuji Electric Corp. of America FRENIC-Mini (C2) product listing. Verified September 2026.

Documentation

Frequently asked questions

What does the OPC-115V do?
It converts 8 channels of 115 VAC user wiring into 24 V DC digital inputs for the inverter, and provides relay outputs on both the user side and the inverter side.
What voltage are the OPC-115V inputs?
The user side takes 115 VAC at 8 mA per channel, with a minimum ON voltage of 96 VAC and a maximum OFF voltage of 36 VAC. The inverter side takes 24 V DC at 12 mA per channel.
What can the OPC-115V relay outputs switch?
User side: 250 VAC 5 A or 24 VDC 5 A per channel across 4 relays. Inverter side: 24 VDC 20 mA per channel across 8 relays.
How is the OPC-115V mounted?
On DIN rail or on a mounting plate. The board measures 145 mm x 92 mm.
Accessory Item:
I/O Card
Accessory Type:
I/O Card
Compatible Series:
FRENIC-Mini (C2)