Functional Devices PSH600-UPS-STAT : 600VA UPS Backup Power Control Center, Status Contacts, 12" x 14" x 6" Metal Enclosure

Functional Devices

MSRP: $900.20
$450.10
(You save $450.10 )
(No reviews yet) Write a Review
SKU:
PSH600-UPS-STAT
Condition:
New
Availability:
Ships in 2-4 Days
Adding to cart… The item has been added

Functional Devices PSH600-UPS-STAT : 600VA UPS Backup Power Control Center, Status Contacts, 12" x 14" x 6" Metal Enclosure

Specifications:

UPS

UPS: 550 or 600VA
Backup Time: 2.5 Min. @ Full 600 VA Load 10 Min. @ 1/2 Load
Power Consumption Up to 3 Amp @120 Vac
Max Load: 330 Watt
Frequency: 50/60 Hz
Temperature Rating of UPS: 32 to 104° F
UPS Transfer Time: 6ms
Approvals: UL Listed, UL1778

 

PSH2C2RB10

Operating Temperature: -30 to 140° F
Humidity Range: 5 to 95% (noncondensing)
Main Breaker ON/OFF: Switch / Breaker (10 Amp)
Approvals: UL Listed, UL916, C-UL, CE, RoHS
Dimensions: 12.000 ̋ H x 14.000 ̋ W x 6.000 ̋ D Metal Housing with
Screw Cover
Origin Made of US and non-US parts

 

Line Input Status Contacts and UPS Output Status Contacts Rated:

  • 10 Amp @ 277 Vac General Use
  • 10 Amp @ 30 Vdc (N/O)
  • 7 Amp @ 30 Vdc (N/C)
  • 1/2 HP @ 125 Vac
  • 1/4 HP @ 277 Vac
  • 1000 VA @ 120 Vac Magnetic Ballast (N/C) C300 Pilot Duty
  • 16.8 VA @ 24 Vac Pilot Duty

Notes:

  • To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2C2RB10.
  • To order interface board for replacement or for separate use, order model PSMN2C2RB10.
  • Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature
  • UPS may change based on quality and availability

UPS Status Contacts and LED Indicator
The UPS status contacts and LED indicate power from the UPS. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay will be energized as long as the UPS can sustain it (until the UPS battery is depleted), and the LED is on.

Input Power Status Contacts and LED Indicator

The input power status contacts and LED indicate the presence of normal power. When normal power is present, the relay is energized, and the LED is on. When normal power is lost, the relay is de-energized, and the LED is off.

Datasheets

pdf logo

Functional Devices PSH600-UPS-STAT Uninterruptible Power Supply Kit Data Sheet

 

Mounting:
Enclosed
Features:
Status Contacts
Number of Relays:
2
Relay Coil voltage:
120 Vac
Contact Ratings:
10 Amp
Circuit Breaker Switch:
10 Amp