null Skip to main content

Miljoco-Weiss V20365102-48 : Remote Reading Vapor Actuated Dial Thermometer, 2 in Dial, Front Flange Flush Mount, 30 to 240°F/C Dual Scale, 48 in Tin Plated Copper Capillary

Miljoco-Weiss

MSRP: $92.40
Your Price:  $87.78
(You save $4.62 )
(No reviews yet) Write a Review
SKU:
V20365102-48
Condition:
New
Adding to cart… The item has been added
Range30 to 240°F/C dual scale
Dial2″
MountingFlush Mount, Front Flange Case
Capillary48″ tin plated copper
Accuracy±One scale division
Case300 series stainless steel

The Miljoco-Weiss V20365102-48 is a Miljoco V2036 remote reading vapor actuated dial thermometer with a 2″ stainless steel front flange case, a 30 to 240°F/C dual scale and a 48″ tin plated copper capillary to a nickel plated copper sensing bulb, accurate to ±one scale division.

These instruments are ideal for obtaining readings from remote locations. Being vapor actuated, they are not subject to ambient temperature variations along the tube system and give readings both above and below ambient.

Vapor instruments have progressive graduations and are best read in the upper two-thirds of the range. Front flange thermometers are designed to be installed in a panel using three screws from the front.

Specifications on this page are taken from the Miljoco vapor actuated dial thermometer datasheet (2004_V20_Series_EN). Verified 2026-09-11.

Warranty

Miljoco-Weiss warrants its products to be free from material defects in material and workmanship for 12 months from the date of shipment, or such other period as provided in the product documentation, per the published Miljoco-Weiss terms and conditions of sale (Section 15, Limited Warranty).

Key Features

Remote reading

Ideal for obtaining readings from remote locations.

Vapor actuated thermal system

Not subject to ambient temperature variations along the tube system.

2″ front flange case

300 series stainless steel case with a rear outlet and polycarbonate, press-in lens.

Brass movement, phosphor bronze Bourdon tube

Brass movement with precision gearing drives a black adjustable pointer.

Dual °F and °C scale

Fahrenheit and Celsius graduations on a 2″ aluminum dial with white finish and black markings.

Technical Specifications

ModelV20365102-48
TypeRemote reading vapor actuated dial thermometer
Ordering CodeModel V2036, range code 51, tube system code 02, capillary length 48″
Temperature Range30 to 240°F/C
Graduations°F scale figure interval 20°, division 2°; °C scale figure interval 10°, division 2°
Dial Size2″
MountingFlush Mount, Front Flange Case
OutletRear
Case300 series stainless steel
LensPolycarbonate, press-in
DialAluminum with white finish and black markings
PointerBlack, adjustable
MovementBrass with precision gearing
Bourdon TubePhosphor bronze
Accuracy±One scale division
Capillary TubingTin plated copper, 48″
ConnectionPlain, no well
Sensing BulbNickel plated copper, 0.438″ diameter, 2.5″ long
Ambient Temperature-40 to 140°F (-40 to 60°C)
Dimensions (in.)A 2.94, B 1.09, C 2.06, D (bolt circle) 2.56
Optional FeaturesHS strain relief at case, TS strain relief at bulb, SD silicone dampening, WP lens O-ring (threaded lens only), RTV case sealant, WH weep hole, OR over range protection

Source Notes

Source note: Capillary length. The general specifications list 60″ tin plated copper capillary as standard. This part number specifies a 48″ capillary through the ordering code, and the datasheet states that other capillary lengths are available. The ordered length is published here.

Documentation

Related Products

Frequently Asked Questions

What range and scale does the V20365102-48 have?

30 to 240°F/C dual scale. °F scale figure interval 20°, division 2°; °C scale figure interval 10°, division 2°.

Where on the scale should the working temperature fall?

Vapor thermometers have progressive graduations and are best read in the upper two-thirds of the scale, so select a range that puts the working temperature in that area.

How long is the capillary and what is the bulb?

48″ of tin plated copper capillary to a nickel plated copper sensing bulb, 0.438″ in diameter and 2.5″ long per the datasheet bulb table.

Does the bulb height matter?

Yes. The datasheet cautions that the sensing bulb and case should be installed at a similar height to maintain the designed accuracy. Advise the factory when ordering if they must be mounted at different heights.

How is it mounted?

It is a 2″ front flange case with a rear outlet, installed in a panel with three screws from the front. Dimension A is 2.94 in. and bolt circle D is 2.56 in.

Manufacturer Warranty

Miljoco-Weiss warrants this product to be free from material defects in material and workmanship for 12 months from date of shipment, per the published Miljoco-Weiss terms and conditions of sale.

Warranty service requires written notice of the defect within seven days of discovery. Remedy is repair, replacement or credit at the manufacturer's discretion. Normal wear, corrosion, misuse and unauthorized modification are excluded.

Type:
Vapor Actuated Dial Thermometer
Series:
V20
Dial Size:
2 in
Mounting:
Front Flange Flush Mount
Connection Location:
Rear
Temperature Range:
30/240°F
Scale:
Dual °F/°C
Capillary Length:
48 in
Capillary Material:
Tin Plated Copper
Case Material:
Stainless Steel
Accuracy:
Plus or Minus 1 Scale Division