null Skip to main content

Prolon PL-PN3-1A-7X-7X : Pre-Wired 3-Controller HVAC Panel, NC2000 Network Controller with Touchscreen + Two M2000 Controllers, UL Listed, Modbus RTU / TCP-IP

Prolon

$7,243.28
(No reviews yet) Write a Review
SKU:
PL-PN3-1A-7X-7X
Condition:
New
Availability:
Ships in 2-4 Days
Adding to cart… The item has been added

Prolon PL-PN3-1A-7X-7X : Pre-Wired 3-Controller HVAC Panel — NC2000 Network Controller with 10” Touchscreen + Two M2000 Controllers, UL Listed, Modbus RTU / TCP-IP

Part Number
PL-PN3-1A-7X-7X
 
Panel Type
3-Controller Pre-Wired
 
Controllers
NC2000 (HMI) + 2x M2000
 
Display
10” Touchscreen Included
 
Certification
UL916 Listed

The Prolon PL-PN3-1A-7X-7X is a pre-wired, UL-certified 3-controller HVAC control panel configured with one NC2000 Network Controller with integrated 10-inch touchscreen and two M2000 flexible field controllers. The panel arrives fully assembled and pre-wired in a NEMA 1 industrial enclosure with clearly marked terminal blocks, isolation relays on all digital outputs, overcurrent fuse protection, and wire management channels — ready for fast, clean, repeatable field installation.

What the X Means in PL-PN3-1A-7X-7X

The 7 in positions 3 and 5 designates the M2000 controller type. The X designates the application program — the M2000 is a flexible multi-application controller that can be flashed into different programs including RTU, MUA, FCU, FLX, CHL, HP, HPS, and more. The application is configured at commissioning using the free Prolon FOCUS software. Contact ZOT Supply or use the Project Portal if you need a panel configured for a specific application combination.

Slot 1 — NC2000 with HMI

NC2000 Network Controller

The master network controller for the Prolon system. Manages up to 127 nodes on the Modbus RS485 network and provides Modbus TCP/IP connectivity via Ethernet. Includes the integrated 10-inch Android touchscreen running Prolon FOCUS for local configuration, monitoring, and setpoint adjustment without a laptop. Also supports USB and SD card for data logging and firmware updates.

Slot 2 — M2000 Controller

M2000 Field Controller #1

The Prolon M2000 is a multi-application field controller with 9 configurable analog inputs, 5 triac digital outputs, and 3 analog outputs. Supports thermistor, dry contact, 4-20mA, and 0-10VDC inputs. Can be flashed into RTU, MUA, FCU, FLX, CHL, HP, HPS, HYD, and other programs. Application is selected at commissioning.

Slot 3 — M2000 Controller

M2000 Field Controller #2

Second M2000 field controller, independently configurable for any supported application program. Controllers do not need to be related in function — each can serve a completely different sequence from a separate power source. This makes the PL-PN3 suitable for mixed-application installations in a single panel.

Pre-Wired & Ready to Deploy

The panel ships fully assembled with all controllers pre-wired, terminal blocks clearly marked, and fuses installed. Field installation is limited to connecting power, equipment wiring, and communication. Dramatically reduces panel build time and eliminates wiring errors on the job site. Consistent, repeatable deployment across multiple panels on the same project.

Integrated 10” Touchscreen Display

The NC2000 HMI option includes a built-in 10-inch Android tablet running Prolon FOCUS pre-loaded. Allows technicians and building operators to monitor all points, adjust setpoints, change schedules, configure controllers, and run diagnostics directly at the panel — no laptop or separate device required. Password protection and limited access mode available.

Isolated Digital Outputs

All digital outputs on the M2000 controllers are isolated with relays built into the panel. This protects the controllers from load-side transients and provides clean, reliable switching of HVAC equipment. LED indicators on each output allow for quick visual diagnostics of power, communication, and operational status without opening the panel.

Modbus RTU + TCP/IP Network Ready

The NC2000 provides Modbus RTU (RS485) for field device communication and Modbus TCP/IP for BMS integration and remote access via Ethernet. Supports static IP or DHCP. This panel counts as 3 nodes on the network. Up to 127 total nodes supported per NC2000 network. Remote configuration and monitoring via free Prolon FOCUS software.

 

Rooftop Unit (RTU) Control

One or both M2000s flashed as RTU controllers for multi-unit rooftop installations from a single panel

 

Make-Up Air Unit (MUA)

M2000 in MUA Standard or MUA Advanced program for dedicated outdoor air systems and kitchen ventilation

 

Fan Coil Unit (FCU) Control

M2000 in FCU program for fan coil unit zone control, integrated with NC2000 for network scheduling

 

Mixed-Application Installations

Each M2000 can run a completely different program — e.g. one RTU and one MUA in the same panel

 

Heat Pump Systems (HP / HPS)

M2000 in HP or HPS program for heat pump control, reversing valve sequencing, and defrost logic

 

Flexible / Custom Sequences (FLX)

M2000 in FLX program for non-standard equipment sequences where a custom I/O mapping is required

Specification Value
Part Number PL-PN3-1A-7X-7X
Panel Type Pre-Wired 3-Controller Panel (PL-PN3)
Controller 1 NC2000 Network Controller with 10” HMI Touchscreen
Controller 2 M2000 Field Controller (application field-configurable)
Controller 3 M2000 Field Controller (application field-configurable)
Supply Voltage 24 VAC ±10%, 50/60 Hz, Class 2
NC2000 Power (HMI) 30 VA
M2000 Power 5 VA consumption, 40 VA input per controller
M2000 Inputs 9 analog inputs per controller — thermistor / dry contact / 4-20mA / 0-5VDC / 1-5VDC, individually configurable
M2000 Digital Outputs 5 triac outputs per controller, 24VAC source, 300mA max (resettable fuse). All isolated by panel relays.
M2000 Analog Outputs 3 outputs per controller — 0-10VDC / 2-10VDC / 0-5VDC / 1-5VDC, 40mA max
Overcurrent Protection Disconnect-style Slo-Blo fuse, 3A @ 250VAC, with replacement fuse included
Communication — Field Modbus RTU (RS485) up to 127 nodes. This panel = 3 nodes.
Communication — BMS / Remote Modbus TCP/IP (static IP or DHCP), USB, Ethernet via NC2000
Baud Rates 9600, 19200, 38400, 57600, 76800, 115200
Terminal Blocks Removable screw-type, 16 AWG maximum
Panel Dimensions 24.25” x 24.25” x 6.25” (610mm x 610mm x 159mm)
Weight 67 lbs (30.5 kg)
Housing NEMA 1, Molded ABS, UL94-HB
Operating Temperature -4 to 122°F (-20 to 50°C), non-condensing
Certification UL916 Energy Management Equipment, CAN/CSA-C22.2, RoHS, FCC Part 15: 2012 Class B
Software Prolon FOCUS (free) — available at proloncontrols.com
UL916 Energy Management Equipment CAN/CSA-C22.2 RoHS FCC Part 15 Class B NEMA 1 Modbus RTU RS485 Modbus TCP/IP
<
What does PL-PN3-1A-7X-7X mean?
PL-PN3 is the 3-controller panel format. 1A designates the NC2000 Network Controller with integrated 10-inch HMI touchscreen in slot 1. 7X designates an M2000 field controller in slots 2 and 3. The X in the application position means the controller program is configured at commissioning using Prolon FOCUS software. The M2000 can be flashed into any supported application including RTU, MUA, FCU, FLX, CHL, HP, HPS, and others.
Do the two M2000 controllers have to run the same application?
No. Each M2000 in the panel is independently configurable and can run a completely different controller program from a separate power source. For example, one M2000 can be configured as an RTU controller while the second runs a MUA sequence. This makes the PL-PN3 ideal for mixed-equipment installations where multiple unrelated HVAC systems share a single control panel location.
What is the NC2000 HMI touchscreen used for?
The NC2000 with HMI includes a built-in 10-inch Android tablet running Prolon FOCUS. It allows technicians and operators to connect to the project, discover controllers on the network, configure controller programs, adjust zone temperature setpoints, change schedules, override outputs, and run diagnostics — all directly at the panel without a laptop. Password protection and limited access mode restrict unauthorized changes.
How many Modbus nodes does this panel use?
The PL-PN3 with three controllers counts as 3 nodes on the Modbus RS485 network. The NC2000 supports up to 127 total nodes, so this panel leaves 124 node addresses available for additional controllers, sensors, and field devices on the same network.
Can this panel be integrated into a building management system (BMS)?
Yes. The NC2000 provides Modbus TCP/IP via Ethernet for BMS integration, supporting static IP or DHCP addressing. This allows a third-party BMS or building automation system to communicate with all controllers in the panel and across the entire Prolon network through a single IP connection to the NC2000.
What software is used to configure Prolon controllers?
Prolon FOCUS is the free configuration and commissioning software for all Prolon controllers. It is available for PC download at proloncontrols.com and also runs on the integrated HMI tablet in this panel. FOCUS allows you to discover controllers, assign programs, configure sequences, adjust setpoints, and monitor live system status. Wiring diagrams for all controller programs are available free at proloncontrols.com.

Panel Type:
Three Controller Panel
Display: