null Skip to main content

Prolon PL-TUB14-FSD : 14 in. Round Inlet VAV Terminal Box with PL-FSD Flow Sensor, 16 x 15 in. Rectangular Discharge, 1,600 CFM Max Airflow, 1/2 in. Micromat Insulation, Double Blade Damper, 22 ga G90 Galvanized Steel

Prolon

Your Price:  $640.02
(No reviews yet) Write a Review
SKU:
PL-TUB14-FSD
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
Nominal Size14 in. round
Max Airflow1,600 CFM (755 L/s)
Flow SensorPL-FSD, K 2.14
Discharge16 x 15 in.
Insulation1/2 in. Micromat
Casing22 ga G90 galvanized
The Prolon PL-TUB14-FSD is a 14 in. round inlet terminal box for variable air volume applications, rated for a maximum airflow of 1,600 CFM (755 L/s). It has a 16 x 15 in. rectangular discharge, 1/2 in. Micromat insulation, a double blade damper with polymer seal and a 22 ga. G90 galvanized steel casing. It is supplied with the Prolon PL-FSD flow sensor, which measures the velocity pressure of the air through the box (K factor 2.14 for the 14 in. duct diameter).

Specifications per the Prolon Terminal Box PL-TUB datasheet, doc 802-00028-009 (V9) and the Prolon Flow Sensor (PL-FSD) datasheet REV 7.1.0 (PL-DATA-FSD-C/F-EN). Reviewed September 26, 2026.

The PL-TUB14-FSD takes supply air in through its 14 in. round inlet and delivers it through a 16 x 15 in. rectangular discharge with a slip and drive duct connection. The Micromat insulation has its edges protected by a J-shaped metal trim to prevent air erosion. The PL-FSD flow sensor measures the dynamic pressure corresponding to air velocity through the box, and its 1/4 in. high and low pressure ports connect by tubing to the airflow sensor of a VAV zone controller.

Best For

  • Variable air volume applications using a 14 in. nominal round inlet and 16 x 15 in. rectangular discharge, up to 1,600 CFM.
  • Variable air volume applications using the PL-FSD sensor to measure velocity pressure through the measurement location.

Warranty

For warranty coverage on this Prolon item, contact ZOT Supply at sales@zotsupply.com or 855-825-2811.

Key Features

1,600 CFM Max Airflow

Rated for a maximum airflow of 1,600 CFM (755 L/s) at the 14 in. size.

Micromat Insulated

1/2 in. Micromat insulation in accordance with NFPA 90A/90B/255, ASTM E-84, SMACNA, UL 181/723 and CAN/ULC S102.

Rectangular Discharge

16 x 15 in. discharge with slip and drive duct connection.

Double Blade Damper

Damper in 22 ga. G90 galvanized steel with a polymer seal, on a 1/2 in. black zinc plated drive shaft.

Protected Liner Edges

A J-shaped metal trim protects the insulation edges to prevent air erosion.

PL-FSD Flow Sensor

Four total pressure rods and two static pressure tubes feed a center core with 1/4 in. high and low pressure ports.

Authorized Distributor

ZOT Supply is an authorized distributor of Prolon products.

Technical Specifications

SpecificationValue
ModelPL-TUB14-FSD
SeriesProlon PL-TUB terminal box
Nominal Size14 in.
Max Airflow1,600 CFM (755 L/s)
Inlet Diameter (Dia D)13.875 in.
Discharge Width (Dim A)16 in. (406.4 mm)
Discharge Height (Dim B)15 in. (381 mm)
Casing22 ga. G90 galvanized steel casing
DamperDouble blade damper in 22 ga. G90 galvanized steel with polymer seal
Drive Shaft1/2 in. (12.7 mm) black zinc plated drive shaft
Insulation1/2 in. (12.7 mm) Micromat insulation in accordance with NFPA 90A/90B/255, ASTM E-84, SMACNA, UL 181/723 and CAN/ULC S102
Insulation EdgesProtected by a J-shaped metal trim to prevent air erosion
DischargeRectangular discharge with slip and drive duct connection
Inlet ConnectionSleeve small end 1 in. for connection at inlet
Flow SensorProlon PL-FSD
Flow Sensor Duct Diameter14 in. (356 mm)
Flow Sensor K Factor2.14
Flow Sensor ConstructionFour rods measure total pressure and two angular tubes measure static pressure, coupled to a center core with two chambers that centralize, amplify and balance the readings
Measurement OpeningsLocation and diameter of the measurement openings on each rod conform to Standard III of ASHRAE
Flow Sensor MaterialMolded ABS plastic, pre-treated to meet the UL94 standard regarding flame spread in buildings
Pressure Ports1/4 in. high pressure port and 1/4 in. low pressure port
ApplicationVariable air volume

Documentation

Frequently Asked Questions

What is the maximum airflow of the Prolon PL-TUB14-FSD?

The PL-TUB14-FSD is rated for a maximum airflow of 1,600 CFM (755 L/s).

What size is the discharge on the Prolon PL-TUB14-FSD?

The PL-TUB14-FSD has a 16 x 15 in. (406.4 x 381 mm) rectangular discharge with a slip and drive duct connection, and a 14 in. round inlet with a Dia D of 13.875 in.

Is the PL-TUB14-FSD insulated?

Yes. The PL-TUB14-FSD is lined with 1/2 in. (12.7 mm) Micromat insulation in accordance with NFPA 90A/90B/255, ASTM E-84, SMACNA, UL 181/723 and CAN/ULC S102, with the insulation edges protected by a J-shaped metal trim.

What is the K factor of the flow sensor on the PL-TUB14-FSD?

The PL-FSD flow sensor for a 14 in. duct diameter has a K factor of 2.14.

Where is the flow sensor K factor entered on a Prolon VAV controller?

In Prolon Focus software, duct setup takes the duct diameter in which the flow sensor is installed and the K factor of the flow sensor. Both are needed before running the Focus auto calibrate procedure.

How do I connect tubing to the PL-FSD on the PL-TUB14-FSD?

The PL-FSD has a 1/4 in. high pressure port and a 1/4 in. low pressure port. Run each to the matching high and low airflow inlet on the zone controller.

What is the PL-TUB14-FSD made of?

The casing is 22 ga. G90 galvanized steel, and the double blade damper is 22 ga. G90 galvanized steel with a polymer seal.

Size:
14 Inch
Flow Sensor:
With Flow Sensor