Skip to main content

Senva AQ2D-AC2AAAX : Duct Mount TotalSense RH/CO2 Sensor, Selectable Outputs: 4-20 mA, 0-5 VDC, or 0-10 VDC, CO2, 2% RH Accurracy, No Display, Buy American Act Compliant, 7-Year Limited Warranty

Senva

MSRP: $630.00
$249.00
(You save $381.00 )
(No reviews yet) Write a Review
SKU:
AQ2D-AC2AAAX
Condition:
New
Availability:
Ships in 2 Days
Adding to cart… The item has been added

Senva AQ2D-AC2AAAX : Duct Mount TotalSense Sensor, Selectable Outputs: 4-20 mA, 0-5 VDC, or 0-10 VDC, CO2, 2% RH Accurracy, No Display, Buy American Act Compliant, 7-Year Limited Warranty

Enhance building health and occupant comfort with the Senva AQ2D-AC2AAAX, a duct-mounted air quality sensor. This sensor measures CO2, temperature, and relative humidity, providing valuable data for optimized ventilation control.

Key features include:

  • Selectable outputs: Choose between 4-20mA, 0-5VDC, or 0-10VDC for seamless integration with building automation systems.
  • High accuracy: Measures CO2 with ±30ppm + 3% of reading accuracy and relative humidity with ±2% accuracy.
  • Wide range: Monitors CO2 levels from 0-10,000ppm (programmable) and temperature from -10 to 50°C.
  • Fast response: Reaches 90% of the actual reading within 90 seconds.
  • Durable construction: Enclosed in ABS plastic for long-lasting performance.
  • Easy installation: Mounts directly inside air ducts.

Maintain a healthy indoor environment with the Senva AQ2D-AC2AAAX. This sensor is ideal for schools, offices, hospitals, and other buildings focused on improving air quality and occupant well-being.

Specifications

Power Supply 16-30VDC/24VAC(1), 3.5W nominal, 4W max.
Analog Outputs 0-5V, 0-10V, 4-20mA (switch selectable)
Relay Type Solid-state output, 1A @ 30VAC/DC, N.O.
Relay Polarity NO/NC (selectable)
CO2
 
Type Non-dispersive Infrared (NDIR)
Accuracy ±(30ppm + 3% of reading) (400-2,000ppm), -10-50ºC, 0-85%RH
±(50ppm+ 5% of reading) (2,000-5,000ppm), -10-50ºC, 0-85%RH
>5,000ppm consult factory
Resolution 1 ppm
Range 0-2,000 PPM (Default) (Programmable up to 10,000ppm)
Response time
90 seconds to 90% reading
Response Rate 1s
Temp and Pressure Compensation
Yes, barometric pressure readable over comms
Relative Humidity 2% models, +/-2% over 0 to 80%RH range
Enclosure ABS Plastic / 4.0"h x 4.4"w x x2.1"d (+6.8" probe)
Compliance CE, RoHS

 

Datasheets

pdf logo Senva AQ2D TotalSense RH/CO2 TotalSense Duct
pdf logo Senva AQ2D RH/CO2 Duct Installation
pdf logo Senva AQ2D Display Navigation Guide TotalSense Series
pdf logo Senva Made In USA Certificate 2023
Sensor Type:
Duct
Output Signal:
4-20mA, 0-5 VDC, or 0-10 VDC
CO2 Element:
Yes
Humidity Element:
2%
VOC Element:
None
Temperature Element:
None
Display:
No Display
Supported Protocols:
None