Senva CT1D-D3X : Duct CO2/Temperature Combo Sensor, 1K Platinum RTD, Selectable Outputs: 4-20 mA, 0-5 VDC, or 0-10 VDC, No Display, 7-Year Limited Warranty

Senva

MSRP: $549.02
Your Price:  $236.85
(You save $312.17 )
(No reviews yet) Write a Review
SKU:
CT1D-D3X
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
CO2 Range0-2000 ppm (fixed)
Temp Element1000 Ohm Pt RTD
DisplayNone
Outputs4-20mA / 0-5V / 0-10V
Setpoint RelaySolid-State, Factory-Set
OriginMade in USA

The Senva CT1D-D3X is a duct-mount NDIR carbon dioxide (CO2) transmitter with an integrated passive 1000 Ohm Platinum RTD temperature element. CO2 is reported over selectable 4-20mA, 0-5V, or 0-10V outputs while the 1000 Ohm Pt RTD element returns a raw resistance signal for your building controller to read. An integrated solid-state setpoint relay supports direct ventilation control. This no-display configuration ships at the factory-default 0-2000 ppm range with a fixed setpoint; range, calibration offset, and setpoint thresholds are not field-adjustable without the LCD/menu option.

Specifications sourced from the Datasheet rev. 5/28/2024 (Senva doc #152-0381-0C).

Made in the USASenva builds the CT1D in Beaverton, Oregon. The CT1D series is listed on Senva's 2026 Buy America / BABAA / TAA Commerce Declaration (updated 04/21/2026), with domestic content exceeding 65%. Backed by an industry-leading 7-year limited warranty on electronics. ZOT Supply is an authorized Senva distributor; units ship factory-fresh with the full manufacturer warranty.

Key Features

Self-Calibrating NDIRNon-dispersive infrared CO2 element with selectable Automatic Baseline Correction (ABC) that tracks low ambient CO2 to compensate for long-term IR-source aging.
15+ Year Sensor LifeField-replaceable NDIR CO2 element rated for 15+ years of service for low total lifetime cost.
Solid-State Setpoint RelayBuilt-in solid-state relay (1A @ 30VAC/DC, N.O.) ships at factory-default thresholds (on 800 ppm / off 700 ppm) for standalone on/off ventilation control.
Selectable Analog OutputsDual 3-wire output: 4-20mA plus 0-5V or 0-10V, selectable in the field to match your controller.
1000 Ohm Pt RTD Temperature ElementIntegrated passive 1000 Ohm Platinum RTD (1097 Ohm at 77F (1000 Ohm at 0C nominal)) wired to your controller for temperature; passive elements are not shown on the LCD.

Technical Specifications

Carbon Dioxide (CO2)
Sensing ElementNon-Dispersive Infrared (NDIR)
Output Scaling0-2000 ppm (fixed)
Accuracy (Standard)+/-(30 ppm + 3% of reading), 400-2000 ppm (at -10 to 50C, 0-85% RH). Fixed 0-2000 ppm range; higher ranges require the LCD/menu version.
Drift (ABC disabled)35 ppm/month
Auto-Calibration (ABC)Selectable ON/OFF (default ON)
Pressure Dependency+1% of reading per kPa from nominal (101 kPa)
Response Time60 s to 90% of reading
Sample / Update Rate1 s / 1 s
CO2 Element Life15+ years
SetpointFixed at factory default (on 800 ppm / off 700 ppm); not field-adjustable
Temperature (Passive Element)
Element1000 Ohm Platinum RTD
Nominal Resistance1097 Ohm at 77F (1000 Ohm at 0C nominal)
Connection2-wire resistance to controller; see Senva Thermistor R-T table
LCD Temperature DisplayNo (passive elements not shown on LCD)
Setpoint Relay
TypeSolid-state, 1A @ 30VAC/DC, N.O.
Power & Enclosure
Power Supply24 VAC 100 mA max / 12-30 VDC 50 mA max (15-30 VDC or 24 VAC required for 0-10V output)
EnclosureABS / Polycarbonate, IP20 / NEMA 1, duct mount
Operating Environment14 to 122F (-10 to 50C), 0-95% RH non-condensing
Dimensions4.0 in H x 4.4 in W x 2.1 in D, plus 6.8 in probe

Documentation

Related Products

Frequently Asked Questions

What CO2 range does the CT1D-D3X use?

This no-display unit is fixed at the factory-default 0-2000 ppm range. The selectable 0-5000 and 0-10000 ppm ranges require the LCD/menu (D-suffix) version.

Does the CT1D-D3X auto-calibrate?

Yes. The NDIR element uses selectable Automatic Baseline Correction (ABC) that tracks low ambient CO2 to offset long-term sensor drift. For continuously occupied spaces or greenhouses, Senva recommends the dual-channel option instead of disabling ABC.

Is the temperature reading shown on the display?

No. The 1000 Ohm Pt RTD is a passive element that returns a raw resistance signal to your controller; passive RTD and thermistor temperatures are not shown on the CT1D LCD. Only the B (transmitter) option displays temperature.

Is the CT1D-D3X made in the USA?

Yes. Senva manufactures the CT1D in Beaverton, Oregon, and the CT1D series is listed on Senva's 2026 Buy America / BABAA / TAA Commerce Declaration with domestic content exceeding 65%.

What is the warranty on the CT1D-D3X?

Senva backs the CT1D with an industry-leading 7-year limited warranty on the electronics; the NDIR sensing module carries a 3-year warranty.

Warranty

Senva backs the CT1D-D3X with an industry-leading 7-year limited warranty on the electronics. The NDIR CO2 sensing module carries a 3-year warranty. The field-replaceable CO2 element keeps total lifetime cost low across the sensor's 15+ year service life.

ZOT Supply is an authorized Senva distributor; your CT1D ships factory-fresh with the full Senva warranty. Warranty covers defects in materials and workmanship under normal use and service. Refer to Senva's published warranty terms for full conditions and exclusions.

Sensor Type:
Duct Mount
CO2 Element:
Yes
Temperature Element:
1000 Ohm Pt RTD
Humidity Element:
None
VOC:
No
Display:
No Display
CO2 Range:
2000ppm Fixed
Supported Protocols:
None
Country of Origin:
USA