null Skip to main content
Image coming soon

Senva CVT-FUSE-C6 : CVT In-Line Fuse Kit, 1/2 Amp 600VAC Slow Blow, 200kA AC Interrupting Rating, Blue Lead, for CVT Voltage Reference Runs Over 20 ft

Senva

MSRP: $140.48
Your Price:  $61.53
(You save $78.95 )
(No reviews yet) Write a Review
SKU:
CVT-FUSE-C6
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
Fuse1/2 Amp · 600VAC Slow Blow
Interrupting200kA AC
LeadBlue
UseCVT Reference Runs >20 ft

The Senva CVT-FUSE-C6 is a blue-lead in-line fuse kit for Senva CVT Current/Voltage Transducer installations, providing a 1/2 Amp, 600VAC slow-blow fuse with a 200kA AC interrupting rating. It supplies the overcurrent protection required when a CVT voltage reference run exceeds 20 ft (runs under 10 ft require no fusing per UL 240.21 tap-rule guidance).

Senva CVT-FUSE-C6 CVT Fuse Kit

Senva's CVT architecture keeps all high-voltage connections within the CVT enclosure, and per UL 240.21 tap-rule guidance no overcurrent protection is required for voltage reference runs under 10 ft. When a reference run must exceed 20 ft, this in-line fuse kit provides the required protection without consuming panelboard breaker space.

Best For

  • CVT voltage reference runs over 20 ft
  • Remote meter base placement outside the panel
  • Retrofit metering with long wiring paths

Key Features

1/2A 600VAC Slow Blow

Correctly sized protection for CVT voltage reference taps, with a 200kA AC interrupting rating.

Blue Lead for Phase ID

Matches the blue-lead CVT phase color convention for clean, phase-identified installs.

For Long Reference Runs

Required when a CVT voltage reference must exceed 20 ft; runs under 10 ft need no overcurrent protection per UL 240.21 guidance.

In-Line Simplicity

Installs directly in the CVT voltage reference wiring — no panelboard breaker space needed.

Technical Specifications

Specifications verified against the Senva CVT Series datasheet.

Fuse
Fuse Type1/2 Amp, 600VAC slow blow
Interrupting Rating200kA AC
Lead ColorBlue
Application
Use CaseOvercurrent protection for CVT voltage reference runs over 20 ft
NoteRuns under 10 ft require no fusing per UL 240.21 tap-rule guidance

Documentation

Related Senva Metering Products

CVT Current/Voltage Transducers

The transducers this kit protects — 300A to 6000A flexible split-core Rogowski CVTs.

Senva EM-RS485

Protocol energy meter for CVT installations.

Senva EM-PULSE

Pulse-output energy meter for CVT installations.

Frequently Asked Questions

When do I need the CVT-FUSE-C6?

When a CVT voltage reference run exceeds 20 ft. Senva ships EM Series meters with no more than 10 ft of voltage reference wire per CVT, and runs under 10 ft require no overcurrent protection per UL 240.21 tap-rule guidance.

What fuse does the kit use?

A 1/2 Amp, 600VAC slow-blow fuse with a 200kA AC interrupting rating — matched to the CVT voltage reference circuit.

What does the blue lead indicate?

Lead color follows the CVT phase color convention (black, red, blue), so the fuse kit can match the phase it protects.

Product Line:
CVT Series
Product Type:
Fuse Kit
Lead Color:
Blue
Fuse Rating:
1/2A 600VAC Slow Blow