null Skip to main content

Senva P5-0100-1LP P5 Universal Dry Pressure Transmitter, 0-1 in WC Base with 4 Selectable Sub-Ranges, Field-Selectable Output (4-20mA/0-5V/0-10V), Uni or Bi-Directional, +/-1.00% Accuracy, LCD Display, Duct Probe, BAA Compliant, Made in USA

Senva

MSRP: $340.14
$150.19
(You save $189.95 )
(No reviews yet) Write a Review
SKU:
P5-0100-1LP
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added
Base Range0-1 in WC
Sub-Ranges4 Selectable
DirectionUni or Bi (Switch)
Output Signal4-20mA (2W/3W), 0-5V, 0-10V
Accuracy+/-1.00% of range
DisplayLCD Display
Duct ProbeIncluded
OriginMade in USA

The Senva P5-0100-1LP is part of the Senva P5 Series Universal Dry Pressure Transmitter family - the multi-configuration unit in Senva's dry-pressure lineup. One SKU replaces multiple fixed-range transmitters in your stock: this unit's 0-1 in WC base scales to four selectable sub-ranges (settable via internal slide switch), with field-selectable output signal (4-20 mA 2-wire loop, 4-20 mA 3-wire, 0-5 VDC, or 0-10 VDC) and field-selectable direction (unidirectional or bidirectional). Built around a MEMS silicon piezoresistive sensor with non-position-sensitive design, manual or contact-closure auto-zero, and a patented enclosure with high-density DIN-rail mount and 3/8 in conduit-ready entry. This SKU ships with the optional LCD display for on-board pressure readout and the integrated duct probe with gasketed dampening tip for in-duct installation.

Universal = Inventory Reduction. The P5 is engineered to replace multiple fixed-range transmitters with a single stocking SKU. One technician visit, one part number on the truck - field-set the range, the output signal, and the direction to match the application. Eliminates call-backs caused by stocking the wrong range or output type, and reduces purchasing complexity for OEM and BAS contractors managing many sites.
Best for: low-pressure room and zone applications - building static pressure, clean room and isolation room differential, and laboratory exhaust hood proving. The universal output and selectable sub-range make this the right pick for OEM and BAS contractors who want one part number that fits many applications across their installed base.
7-YEAR
WARRANTY
Industry-leading 7-year limited warranty. Senva backs the P5 Series electronics for seven years - significantly longer than typical 2-5 year warranties on competing pressure transmitters. ZOT Supply is an authorized Senva distributor; product ships factory-new from Beaverton, Oregon with full manufacturer warranty intact.
Buy American Act (BAA) / BABAA / TAA / ARRA Compliant. The Senva P5 Series is manufactured in the USA with over 65% domestic component cost and qualifies under Buy American Act, Build America Buy America Act (BABAA), Trade Agreements Act (TAA), and American Recovery and Reinvestment Act (ARRA Section 1605) for federal, state, and municipal procurement contracts. Senva's current Commerce Declaration (updated April 2026) is available from ZOT on request.

Key Features

Universal Output + Sub-Range

Four field-selectable output signals (4-20 mA 2-wire loop, 4-20 mA 3-wire, 0-5 VDC, 0-10 VDC) on a single internal switch. Four selectable sub-ranges on another switch. Field-selectable unidirectional or bidirectional via a third switch. One stocking SKU covers what would otherwise be 16+ fixed-range parts.

MEMS Silicon Piezoresistive Sensing

Solid-state silicon sensing element with precision factory calibration. Non-position-sensitive design - mount flat, vertical, or DIN-rail without zero shift. Thermal drift is 0.02% FSO per deg C (0.01% per deg F) referenced to 72 F. Accuracy is +/-1.00% of selected range typical.

0-1 in WC Base + Four Sub-Ranges

Base full-scale: 0-1 in WC. Selectable sub-ranges in unidirectional mode: 0.1, 0.25, 0.5, 1.0 in WC. Selectable bidirectional sub-ranges: +/-0.1, +/-0.25, +/-0.5, +/-1.0 in WC. Set via slide switches inside the enclosure - power off before changing.

Manual + Contact-Closure Auto-Zero

Front-panel pushbutton zero plus a separate remote-zero terminal that accepts a normally-open contact closure - useful for programmatic re-zeroing from the BAS. Press and hold ZERO SET for 2 seconds with no pressure applied (or with H and L ports tied together) to re-zero. Zero drift <0.004 in WC per year.

Patented DIN-Rail + Conduit-Ready Mount

Patented enclosure design with two DIN-rail orientations - back-mount for standard depth or side-mount for high-density panels. Integrated 3/8 in flex conduit cover with 3/4 in knockout means no separate fittings needed for typical commercial install.

LCD Display + Duct Probe Included

Ships with the on-board LCD for live pressure readout AND the integrated duct probe with gasketed dampening tip for stable in-duct measurements. The fully-loaded configuration - direct duct mount with on-board readout, no accessories to add.

Selectable Sub-Ranges & Outputs

This SKU is the 0-1 in WC base unit. All field-selectable options are set with slide switches inside the enclosure. Power must be off when changing switches.

Selectable OptionAvailable Settings
Base Full-Scale Range0-1 in WC
Unidirectional Sub-Ranges (4)0.1 in WC, 0.25 in WC, 0.5 in WC, 1.0 in WC
Bidirectional Sub-Ranges (4)+/-0.1 in WC, +/-0.25 in WC, +/-0.5 in WC, +/-1.0 in WC
Selection MethodInternal slide switch (Pressure Range Selector)
Direction SelectionInternal slide switch (Uni/Bi-Directional Selector)
Output SelectionInternal slide switch (Output Type Selector): 4-20 mA 2-wire / 4-20 mA 3-wire / 0-5 VDC / 0-10 VDC

Technical Specifications

SpecificationValue
ModelP5-0100-1LP
SeriesP5 Universal Dry Pressure
Base Pressure Range0-1 in WC
Selectable Sub-Ranges (Uni)0.1 in WC, 0.25 in WC, 0.5 in WC, 1.0 in WC
Selectable Sub-Ranges (Bi)+/-0.1 in WC, +/-0.25 in WC, +/-0.5 in WC, +/-1.0 in WC
DirectionField-selectable (Uni or Bi) via internal switch
Output SignalsField-selectable: 4-20 mA 2-wire loop / 4-20 mA 3-wire / 0-5 VDC / 0-10 VDC
Supply Voltage12-30 VDC or 24 VAC (+/-10%), 30 mA max
Accuracy+/-1.00% of selected range (combined non-linearity, hysteresis, and repeatability at 70 F)
Sensor TypeMEMS silicon piezoresistive, precision calibrated
Zero FunctionPushbutton + N.O. contact-closure auto-zero
Zero ToleranceIncluded in accuracy specification
Span Tolerance+/-1.00% (+/-1% +/-0.005 in WC for ranges under 0.10 in WC)
Zero Drift (1 year)0.004 in WC/year max (0.4% for units over 0.5 in WC)
Thermal Shift0.02% FSO per deg C (0.01% FSO per deg F), measured from 22 C (72 F)
Response Rate8 seconds (full scale)
Overpressure41.5 in WC
Max Static Line Pressure41.5 in WC
Burst Pressure83 in WC
Position SensitivityNon-position sensitive
Operating Temperature-4 to 140 F (-20 to 60 C)
Compensated Temperature-4 to 140 F (-20 to 60 C)
Operating Humidity0 to 95% RH, non-condensing
Media CompatibilityDry, oil-free air or nitrogen (N2)
Display5-digit LCD
Duct ProbeIntegrated gasketed probe with dampening tip
Enclosure MaterialUL94-5VB rated, ABS
Enclosure RatingNEMA 1
Conduit Entry3/8 in flex conduit cover with 3/4 in knockout (integrated)
Tubing ConnectionHose barbs, accepts 1/8 in and 1/4 in ID tubing
DIN Rail MountingBack or side (two orientations) - patented design
Terminal Torque3.5 in-lb
Dimensions4.75 x 1.82 x 0.90 in (transmitter); 5.16 x 1.82 x 0.90 in with display variant
Weight0.22 lb
ComplianceCE, RoHS
Procurement ComplianceBuy American Act (BAA), BABAA, TAA, ARRA Section 1605
Country of OriginMade in USA - Beaverton, Oregon (over 65% domestic component cost)
Warranty7-year limited (electronics)
Manufacturer Part NumberP5-0100-1LP

Documentation

Frequently Asked Questions

What sub-ranges and outputs does the P5-0100-1LP support?
This is the 0-1 in WC base unit. Inside the enclosure are slide switches that let you field-select the sub-range (4 unidirectional options: 0.1, 0.25, 0.5, 1.0 in WC, or 4 bidirectional options: +/-0.1, +/-0.25, +/-0.5, +/-1.0 in WC) and the output signal (4-20 mA 2-wire loop, 4-20 mA 3-wire, 0-5 VDC, or 0-10 VDC). Direction (uni or bi) is a separate switch. Power off the unit before changing any switch positions; new settings don't take effect until power is cycled.
How is the P5 different from the P4 Series?
The P5 is the Universal version of Senva's dry-pressure family. Where the P4 uses fixed ranges and fixed outputs (one SKU per range/output combination), the P5 lets you field-select the sub-range, the output signal, and the direction on a single unit. This means one P5 SKU can replace multiple P4 SKUs in inventory and on the truck. The trade-off: the P5 carries a +/-1.00% accuracy spec (vs the P4 Precision option at 0.25% or 0.50% NIST). Pick the P5 when inventory flexibility matters; pick a P4 Precision when documented NIST accuracy is required.
How do I wire the output signal?
Three terminals plus a remote-zero contact terminal. For 4-20 mA 2-wire loop: connect supply (12-30 VDC) and the 4-20 mA receiver in series through PWR and COM. For 4-20 mA 3-wire: PWR to supply +, COM to supply common, and the 4-20mA 3-Wire Out terminal to the receiver. For 0-5 VDC or 0-10 VDC: PWR, COM, and the 0-5/10V Out terminal. The Remote Zero terminal accepts a dry (N.O.) contact closure to trigger an auto-zero remotely. Tighten terminals to 3.5 in-lb. For 24 VAC supply, Senva recommends a dedicated isolation transformer since one side of the secondary ties to signal common.
What does the LCD display show?
The 5-digit LCD shows live differential pressure in the configured units. It's useful during commissioning, filter-loading testing, and balancing - verify what the transmitter is sensing without a separate manometer. The LED status indicator beside the display flashes every 5 seconds for normal operation, rapidly flashes when applied pressure exceeds 110% of the selected sub-range, and momentarily flashes when a zero operation completes.
What does the included duct probe do?
This SKU ships with an integrated gasketed duct probe that includes a dampening tip - the dampening reduces oscillation from turbulent airflow so the displayed reading stays stable in real duct conditions. The probe threads directly into the back of the enclosure for direct in-duct mounting. For applications where you need the probe in the duct but the transmitter mounted elsewhere, Senva also offers the RP-6 6-inch remote probe (sold separately).
How do I zero the transmitter and what media is it rated for?
The P5 is rated for dry, oil-free air or nitrogen (N2) only - not for wet, oily, corrosive, or particulate-laden media. To zero: with power applied and no differential pressure across the ports (or with the H and L ports temporarily tied together), press and hold the ZERO SET button for 2 seconds. The LED will flash momentarily when the operation completes. The unit also supports remote auto-zero via an N.O. contact-closure input wired to the Remote Zero terminal - useful for triggering periodic re-zero from the BAS to compensate for the long-term zero drift (typically under 0.004 in WC per year).
Brand:
Senva
Series:
P5 Universal Dry Pressure
Product Type:
Universal Dry Media Differential Pressure Transmitter
Base Range:
0-1 in WC
Range Code:
0100
Selectable Sub-Ranges (Uni):
0.1 in WC, 0.25 in WC, 0.5 in WC, 1.0 in WC
Selectable Sub-Ranges (Bi):
+/-0.1 in WC, +/-0.25 in WC, +/-0.5 in WC, +/-1.0 in WC
Number of Selectable Sub-Ranges:
8 (4 uni + 4 bi)
Direction:
Field-selectable Unidirectional or Bidirectional
Output Signal:
Field-selectable: 4-20 mA 2-wire loop / 4-20 mA 3-wire / 0-5 VDC / 0-10 VDC
Supply Voltage:
12-30 VDC or 24 VAC, 30 mA max
Accuracy:
+/-1.00% of selected range
Display:
5-Digit LCD
Duct Probe:
Integrated gasketed probe with dampening tip
Sensor Type:
MEMS silicon piezoresistive
Zero Function:
Pushbutton + N.O. contact-closure remote zero
Zero Drift:
0.004 in WC/year max
Thermal Shift:
0.02% FSO/C (0.01% FSO/F)
Response Rate:
8 seconds full-scale
Overpressure:
41.5 in WC
Max Static Line Pressure:
41.5 in WC
Burst Pressure:
83 in WC
Position Sensitivity:
Non-position sensitive
Operating Temperature:
-4 to 140 F, -20 to 60 C
Operating Humidity:
0 to 95% RH non-condensing
Media:
Dry oil-free air, nitrogen (N2)
Enclosure:
UL94-5VB ABS, NEMA 1
Tubing Accepted:
1/8 in and 1/4 in ID
Conduit Entry:
3/8 in flex (integrated cover with 3/4 in knockout)
DIN Rail Mounting:
Back or side (patented design)
Terminal Torque:
3.5 in-lb
Compliance:
CE, RoHS
Procurement:
Buy American Act (BAA), BABAA, TAA, ARRA Compliant
Country of Origin:
USA (Beaverton, Oregon)
Warranty:
7-year limited

Videos Hide Videos Show Videos