Skip to main content

Senva TGD-BNX-A : Duct Mount Toxic Gas NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, Clear/Tinted Enclosure, 7-Year Warranty

Senva

MSRP: $1,001.70
$400.50
(You save $601.20 )
(No reviews yet) Write a Review
SKU:
TGD-BNX-A
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

Senva TGD-BNX-A : Duct Mount Toxic Gas NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, Clear/Tinted Enclosure, 7-Year Warranty

The Senva TGD-BNX-A is a duct-mount toxic gas NO2 sensor/controller featuring BACnet MS/TP, Modbus RTU, and Modbus ASCII output, as well as an LCD display, all housed in a clear/tinted enclosure with a 7-year warranty. This device is particularly useful in ensuring adequate airflow in occupied spaces, making it ideal for applications such as parking lot garages. The TGD-BNX-A can also alert occupants of elevated gas levels and directly control exhaust fans. The device features a 3-1/2 digit LCD display, LEDs for status indication, and an 85dB piezo transducer for audible alarm exposure. The NO2 sensor is electrochemical, with an accuracy of ±5% of the default range and a resolution of 0.1ppm. The sensor's life expectancy is greater than 7 years, covering an area of 5000-7500 square feet. The enclosure, suitable for both wall and duct installations, is made of ABS/Polycarbonate material and complies with UL61010-1 standards, being UL, cUL, and CE listed.

Applications

  • Ensure adequate air flow in occupied spaces
  • Ideal fo parking lot garages 
  • Alert occupants of elevated gas levels
  • Directly control exhaust fans

Specifications

Power Supply 15-30VDC/24VAC(1), 4W max, 160mA max.
BACnet /Modbus  
Protocol RS-485 BACnet MS/TP, Modbus RTU, Modbus ASCII
Baud Rates 9600, 19200, 38400, 57600, 76800, 115200
Fan Relay  
Fan relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
NO2 fan relay setpoint 1ppm (default), 0-30ppm (menu selectable)
Alarm Relay  
Alarm relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
NO2 alarm relay setpoint 3ppm (default), 0-30ppm (menu selectable)
Display  
3-1/2 digit LCD Indicates NO2 ppm (menu selectable)
LEDs  
Green, Yellow, Red Green = Normal, Yellow = Warning/Fan Relay, Red = Alarm/Alarm Relay
Audible Alarm Exposure  
85dB Piezo transducer 30 minutes above alarm setpoint per UL2034 (menu selectable)
NO2 Sensor Performance  
Type Electrochemical
Accuracy ±5% of default range(3) ±5%of reading above 20ppm
Resolution 0.1ppm
Life expectancy >7 years
Coverage Area 5000-7500 square feet (placed within 50' apart from a Senva TG sensor.)
Enclosure (Wall & Duct)  
Material ABS/Polycarbonate
Dimensions 4.0”h x 4.4”w x 2.1”d (+6.8” probe for duct version)
Conduit Opening Tapped 1/2” NPT
Rating IP20
Compliance UL61010-1 Listed UL, cUL, CE

 

Datasheets

pdf logo Senva TG UL Toxic Gas CO-NO2 Sensor Datasheet
pdf logo Senva TG UL Install Manual
pdf logo TG UL Field Calibration Instructions
pdf logo User’s Guide TG Series
pdf logo Buy America Act Certification
pdf logo Engineering Specifications
pdf logo LADBS Acceptance
pdf logo Application Note Detecting Toxic Gases
pdf logo Understanding Cross-Sensitivities
pdf logo Application Note TG Sensor Placement
pdf logo TG UL Series BACnet User Manual
pdf logo New TGD Duct Mount Toxic Gas Sensors
Enclosure Style:
Duct
Gas Element:
Nitrogen Dioxide
Analog Output:
0
Relay Output:
2 SPDT
Communication:
BACnet MS/TP
Display:
LCD Display

Videos Hide Videos Show Videos