Senva TGM-BCN-AS : Metal Wall Mount Dual Toxic Gas CO/NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, 7-Year Warranty
Protect occupants from harmful CO and NO2 gases with the Senva TGM-BCN-AS, a dual toxic gas sensor/controller for wall mounting. This UL-listed unit features BACnet MS/TP and Modbus communication for seamless building integration, and can also function as a standalone controller. Its 7-year warranty and daisy-chainable design for cost-effective coverage of large areas make it ideal for parking garages and other enclosed spaces.
Key features:
- Dual gas detection: Monitors both carbon monoxide (CO) and nitrogen dioxide (NO2)
- BACnet/Modbus connectivity: Integrates seamlessly with building automation systems
- Standalone controller option: Controls exhaust fans and ventilation directly
- 7-year warranty: Ensures long-lasting performance and peace of mind
- Daisy-chainable design: Cost-effectively covers large areas
- Clear LCD display, LED indicators, and audible alarms: Provide instant status updates
Order your Senva TGM-BCN-AS today and breathe easy knowing your occupants are protected from harmful toxic gases.
Applications
- Ensure adequate air flow in occupied spaces
- Ideal fo parking lot garages
- Monitor multiple toxic gases with one mounted unit
- Alert occupants of elevated gas levels
- Directly control exhaust fans
Specifications
Power Supply | 15-30VDC/24VAC(1), 4W max, 160mA max. |
BACnet /Modbus | |
Protocol RS-485 | BACnet MS/TP, Modbus RTU, Modbus ASCII |
Baud Rates | 9600, 19200, 38400, 57600, 76800, 115200 |
Fan Relay | |
Fan relay characteristics | NO2 fan relay setpoint |
CO fan relay setpoint | 25ppm (default), 0-1000 ppm (menu selectable) |
NO2 fan relay setpoint | 1ppm (default), 0-30ppm (menu selectable) |
Alarm Relay | |
Alarm relay characteristics | N.C. 1A@24/30VDC (50/60Hz) (no mains connection) |
CO alarm relay setpoint | 100ppm (default), 0-1000 ppm (menu selectable) |
NO2 alarm relay setpoint | 3ppm (default), 0-30ppm (menu selectable) |
Display | |
3-1/2 digit LCD | Indicates CO ppm, NO2 ppm (menu selectable) |
LEDs | |
Green, Yellow, Red | Green = Normal, Yellow = Warning/Fan Relay, Red = Alarm/Alarm Relay |
Audible Alarm Exposure | |
85dB Piezo transducer | 30 minutes above alarm setpoint per UL2034 (menu selectable) |
CO Sensor Performance | |
Type | Electrochemical |
Accuracy | ±5% of default range(2) ±5%of reading above 200ppm |
Resolution | 1ppm |
Certifications | UL2034 Listed Component |
Life expectancy | >7 years |
Coverage Area | 5000-7500 square feet (placed within 50' apart from a Senva TG sensor) |
NO2 Sensor Performance | |
Type | Electrochemical |
Accuracy | ±5% of default range(3) ±5%of reading above 20ppm |
Resolution | 0.1ppm |
Life expectancy | >7 years |
Coverage Area | 5000-7500 square feet (placed within 50' apart from a Senva TG sensor.) |
Enclosure (Metal) | |
Material & Enclosure Rating | Powder-coated steel, NEMA 3R |
Dimensions | 5.0”h x 4.3”w x 2.25”d |
Opening | Dual air vents on front lid of enclosure |
Mounting | Pre-drilled for 2x4” electrical box |
Rating | IP20 |
Compliance | UL61010-1 Listed UL, cUL, CE |
Datasheets
- Enclosure Style:
- Wall
- Gas Element:
- Carbon Monoxide / Nitrogen Dioxide
- Analog Output:
- None
- Relay Output:
- 2 SPDT
- Communication:
- BACnet/Modbus
- Display: