Senva TGW-BCN-A : Wall Mount Dual Toxic Gas CO/NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, Clear/Tinted Enclosure, 7-Year Warranty

Senva

MSRP: $1,168.65
$467.25
(You save $701.40 )
(No reviews yet) Write a Review
SKU:
TGW-BCN-A
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

Senva TGW-BCN-A : Wall Mount Dual Toxic Gas CO/NO2 Sensor/Controller, BACnet MS/TP, Modbus RTU, Modbus ASCII Output, LCD Display, Clear/Tinted Enclosure, 7-Year Warranty

Applications

  • Ensure adequate air flow in occupied spaces
  • Ideal fo parking lot garages 
  • Monitor multiple toxic gases with one mounted unit
  • Alert occupants of elevated gas levels
  • Directly control exhaust fans

Specifications

Power Supply 15-30VDC/24VAC(1), 4W max, 160mA max.
BACnet /Modbus  
Protocol RS-485 BACnet MS/TP, Modbus RTU, Modbus ASCII
Baud Rates BACnet MS/TP, Modbus RTU, Modbus ASCII
Fan Relay  
Fan relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
CO fan relay setpoint 25ppm (default), 0-1000 ppm (menu selectable)
NO2 fan relay setpoint 1ppm (default), 0-30ppm (menu selectable)
Alarm Relay  
Alarm relay characteristics N.C. 1A@24/30VDC (50/60Hz) (no mains connection)
CO alarm relay setpoint 100ppm (default), 0-1000 ppm (menu selectable)
NO2 alarm relay setpoint 3ppm (default), 0-30ppm (menu selectable)
Display  
3-1/2 digit LCD Indicates CO ppm, NO2 ppm (menu selectable)
LEDs  
Green, Yellow, Red Green = Normal, Yellow = Warning/Fan Relay, Red = Alarm/Alarm Relay
Audible Alarm Exposure  
85dB Piezo transducer 30 minutes above alarm setpoint per UL2034 (menu selectable)
CO Sensor Performance  
Type Electrochemical
Accuracy ±5% of default range(2) ±5%of reading above 200ppm
Resolution 1ppm
Certifications UL2034 Listed Component
Life expectancy >7 years
Coverage Area 5000-7500 square feet (placed within 50' apart from a Senva TG sensor)
NO2 Sensor Performance  
Type Electrochemical
Accuracy ±5% of default range(3) ±5%of reading above 20ppm
Resolution 0.1ppm
Life expectancy >7 years
Coverage Area 5000-7500 square feet (placed within 50' apart from a Senva TG sensor.)
Enclosure (Wall & Duct)  
Material ABS/Polycarbonate
Dimensions 4.0”h x 4.4”w x 2.1”d (+6.8” probe for duct version)
Conduit Opening Tapped 1/2” NPT
Rating IP20
Compliance UL61010-1 Listed UL, cUL, CE

 

Datasheets

pdf logo Senva TG UL Toxic Gas CO-NO2 Sensor Datasheet
pdf logo Senva TG UL Install Manual
pdf logo TG UL Field Calibration Instructions
pdf logo User’s Guide TG Series
pdf logo Buy America Act Certification
pdf logo Engineering Specifications
pdf logo LADBS Acceptance
pdf logo Application Note Detecting Toxic Gases
pdf logo Understanding Cross-Sensitivities
pdf logo Application Note TG Sensor Placement
pdf logo TG UL Series BACnet User Manual
pdf logo New TGD Duct Mount Toxic Gas Sensors
 
 
Enclosure Style:
Wall
Gas Element:
Carbon Monoxide / Nitrogen Dioxide
Analog Output:
None
Relay Output:
2 SPDT
Communication:
BACnet/Modbus