The CW2 Series air quality sensor is designed for commercial spaces like offices, conference rooms, schools and retail stores. It measures CO2, temperature and humidity (optional) to monitor indoor air quality and ensure compliance with ASHRAE 62.1 standards. The sensor features microprocessor control for stability, self-calibration for easy maintenance, and high accuracy NDIR technology. It's compatible with various BAS controllers and easy to install.

Specifications:

CO2 Measurement Accuracy      ±30 ppm ±3% of measured value
CO2 Measurement Range      0 to 2000/5000 ppm (selectable)
CO2 Measurement Repeatability      ±20 ppm ±1% of measured value
CO2 Measurement Resolution      1 ppm
CO2 Response Time      <60 seconds for 90% step change
CO2 Sensor Type      Non-dispersive infrared (NDIR), diffusion sampling
Color      Matte White
Display Size      2.05 in (52 mm)
Display Type      Segmented LCD, with 3 Buttons
Electrical Wiring Size      Screw terminals, 18-24 AWG
Enclosure Material      High impact ABS plastic
IP Protection      IP20
Input Specifications      Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz
Measurement Type      CO2 / Temperature
Operating Humidity      0 to 95% RH non-condensing
Operating Temperature      0 to 50 °C (32 to 122 °F)
Output Specifications      Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V
Outputs      Analog
Override      Yes
Setpoint Range      Temperature: 0 to 50 °C (32 to 122 °F) / 10 to 35 °C (50 to 95 °F), selectable Fan Speed: Off, Low, Med., High.
Setpoint Specifications      0-10Vdc. Temperature or fan speed (one setpoint type is selectable via dip switch)
Setpoint      Yes
Standards EMC      EN61000 Series - industrial immunity
Standards      CE, UL 916, RCM, ICES-003. REACH, RoHS
Temperature Measurement Accuracy      ±0.3 °C
Temperature Measurement Range      0 to 50 °C (32 to 122 °F)
Temperature Measurement Resolution      0.1 °C (0.1 °F)
Temperature Sensor Type      RTD, 1K Ohm Platinum
Warranty      5 Years

 

Data Sheets

pdf logo Veris CW2LAXC Datasheet
pdf logo Veris CW2 Series Wall Mount 4-in-1 Sensors Data Sheet
pdf logo Veris CW2 Series Wall Mount 4-in-1 Sensors Installation Sheet

 

Sensor Type:
Wall Mount
Temperature Element:
1K Platinum RTD
Supported Protocols:
None
Humidity Element:
None
CO2 Element:
Yes
Setpoint:
Setpoint
Override:
Override
Display:
3-Button LCD Display
Material:
Plastic