Skip to main content

Veris CW2XAXAV : Wall Mount CO2/Temperature/VOC Combo Sensor, Selectable Outputs: 4-20 mA, 0-5 VDC, or 0-10 VDC, Temperature Transmitter, Blank Enclosure, 5-Year Warranty

Veris

MSRP: $419.49
$283.57
(You save $135.92 )
(No reviews yet) Write a Review
SKU:
CW2XAXAV
Condition:
New
Availability:
Ships in 1 to 2 Weeks
Adding to cart… The item has been added

Veris CW2XAXAV : Wall Mount CO2/Temperature/VOC Combo Sensor, Selectable Outputs: 4-20 mA, 0-5 VDC, or 0-10 VDC, Temperature Transmitter, Blank Enclosure, 5-Year Warranty

The CW2 Series air quality sensor is designed for commercial spaces like offices, conference rooms, schools and retail stores. It measures CO2, temperature and humidity (optional) to monitor indoor air quality and ensure compliance with ASHRAE 62.1 standards. The sensor features microprocessor control for stability, self-calibration for easy maintenance, and high accuracy NDIR technology. It's compatible with various BAS controllers and easy to install.

Specifications:

CO2 Measurement Accuracy      ±30 ppm ±3% of measured value
CO2 Measurement Range      0 to 2000/5000 ppm (selectable)
CO2 Measurement Repeatability      ±20 ppm ±1% of measured value
CO2 Measurement Resolution      1 ppm
CO2 Response Time      <60 seconds for 90% step change
CO2 Sensor Type      Non-dispersive infrared (NDIR), diffusion sampling
Color      Matte White
Electrical Wiring Size      Screw terminals, 18-24 AWG
Enclosure Material      High impact ABS plastic
IP Protection      IP20
Input Specifications      Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz
Measurement Type      CO2 / VOC / Temperature
Operating Humidity      0 to 95% RH non-condensing
Operating Temperature      0 to 50 °C (32 to 122 °F)
Output Specifications      Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V
Outputs      Analog
Standards EMC      EN61000 Series - industrial immunity
Standards      CE, UL 916, RCM, ICES-003. REACH, RoHS
Temperature Measurement Accuracy      ±0.2 °C (±0.4 °F) typical
Temperature Measurement Range      0 to 50 °C (32 to 122 °F)
Temperature Measurement Resolution      0.1 °C (0.1 °F)
Temperature Sensor Type      Solid state, integrated circuit
VOC Measurement Accuracy      ±15% of measured value
VOC Measurement Range      0 to 100% AQI for VOC
VOC Output Scale      0 to 1,000 ppb of total VOC (TVOC)
VOC Sensor Type      Solid state

 

Data Sheets

pdf logo Veris CW2XAXAV Datasheet
pdf logo Veris CW2 Series Wall Mount 4-in-1 Sensors Data Sheet
pdf logo Veris CW2 Series Wall Mount 4-in-1 Sensors Installation Sheet

 

 

Sensor Type:
Wall Mount
Temperature Element:
Transmitter
Supported Protocols:
None
Humidity Element:
None
CO2 Element:
Yes
Setpoint:
No Setpoint
Override:
No Override
Display:
No Display
Material:
Plastic