Veris H308 Hawkeye: Micro Split-Core Adjustable Trip Point Current Switch, Contact Type: Normally Open "N/O", Amp Range: 0.75 to 50A, Trip Point: 0.75A or less, Contact Rating: 1.0 A @ 30 VAC/DC, Status LED, 5-Year Warranty

Veris

MSRP: $94.19
$61.70
(You save $32.49 )
(No reviews yet) Write a Review
SKU:
H308
Condition:
New
Availability:
Lead time > 4 weeks. Call 855-825-2811 for product expert.
Adding to cart… The item has been added

Veris H308 Hawkeye : Micro Split-Core Adjustable Trip Point Current Switch, Contact Type: Normally Open "N/O", Amp Range: 0.75 to 50A, Trip Point: 0.75A or less, Contact Rating: 1.0 A @ 30 VAC/DC, Status LED, 5-Year Warranty

Hawkeye H308 adjustable current switches offer high performance, with a wide array of amperage range options. These products can accurately detect belt loss, coupling shear or other mechanical failure on unit vents, exhaust fans, recirculation pumps and other fixed loads down to as little as 1/5 hp.

  • Retrofit or new construction - high performance devices in split-core housings
  • Adjustable trip point - precise current trip point setting
  • Low setpoint - minimum trip point as low as 0.75 A, no need for multiple wraps of the conductor through the sensor, even on loads as small as 1/5 hp
  • Small size - fits easily inside small enclosures
  • Self-gripping iris on split-core housings for easy installation
  • Status LEDs - for easy setup and local indication
  • Induced from monitored conductor sensor power

Applications

  • Detecting belt loss, coupling shear, and mechanical failure
  • Verifying lighting circuit and other electrical service run times
  • Monitoring status of industrial process equipment
  • Monitoring status of critical motors (compressor, fuel, etc.)
  • VFD output on/off status
 

Specifications

Application Building Automation Systems
Current Measurement Range 0.75 - 50 A
Current Sensor type Current Switch, AC
Electrical Wiring Size 24 - 14 AWG (0.2 - 2.1 mm²)
Measurement Type AC Current
Model H308
Monitored Frequency Range 50 - 60 Hz
Monitored Wire Size 0.3" (8 mm)
Mounting Split Core
Output Specifications N.O. 1 A @ 30 VAC/DC
Outputs Switch output
Product Certification UL | CE
Setpoint Adjustable

 

Datasheets

pdf logo Veris Hawkeye H308 Current Switch Data Sheet
pdf logo Veris Hawkeye H308 Current Switch Installation
pdf logo Veris Hawkeye H308 Current Switch Engineering Specifications
pdf logo Veris Hawkeye H308 Current Switch Declaration
Mounting Type:
Split-Core
Setpoint:
Adjustable Trip
Contact Type:
Normally Open
Amp Range:
0.75 to 50A
Trip Point:
0.75 or less
Contact Rating:
1.0 A @ 30 VAC/DC
Contact Termination:
Terminal Strip