Skip to main content

Veris H800 Hawkeye: Solid-Core Fixed Trip Point Current Switch, Contact Type: Normally Open "N/O", Amp Range: 0.25-200A, Trip Point: 0.25A or Less, Contact Rating: 1.0A @ 30VAC/DC, 5-Year Warranty

Veris

MSRP: $26.35
$15.25
(You save $11.10 )
(No reviews yet) Write a Review
SKU:
H800
Condition:
New
Availability:
Ships Same Day
Adding to cart… The item has been added

Veris H800 Hawkeye : Solid-Core Fixed Trip Point Current Switch, Contact Type: Normally Open "N/O", Amp Range: 0.25-200A, Trip Point: 0.25A or Less, Contact Rating: 1.0A @ 30VAC/DC, 5-Year Warranty

The Veris H800 Hawkeye is a solid-core fixed trip point current switch designed for monitoring status in various applications, such as unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern. Featuring a normally open contact type, an amp range of 0.25-200A, and a trip point of 0.25A or less, this switch offers reliability surpassing traditional relays across auxiliary contacts. It is particularly well-suited for direct-drive units, fan coil units, and exhaust fans. The low setpoint, with a minimum trip point as low as 0.25A, eliminates the need for multiple wraps of the conductor through the sensor, even on small loads. The removable mounting bracket provides installation flexibility, and its solid-core design enables quick retrofit installation. The H800 is induced from the monitored current sensor power and comes with a 5-year warranty. It is certified by UL and CE, ensuring product quality and safety.

The Veris Hawkeye H800 on/off current switches provide a cost-effective solution for monitoring status on unit vents, exhaust fans, recirculation pumps and other fixed loads where belt loss is not a concern. Veris has applied new technology to the Veris Hawkeye H800 model to achieve impressive improvement in turn-on levels.

  • More reliable for status than relays across auxiliary contacts
  • Ideal for direct-drive units, unit vents, fan coil units, exhaust fans, and other fixed loads
  • Low setpoint - minimum trip point as low as 0.25 A, avoids the need for multiple wraps of the conductor through the sensor even on loads as small as 1/5 hp
  • Removable mounting bracket provides installation flexibility
  • Quick installation - solid-core for fast retrofit installation
  • Induced from monitored current sensor power

Applications

  • Electrical load status
  • Direct-drive units, exhaust fans, process motors, and other fixed loads
  • Lighting run times and status
  • VFD output On/Off status
  • Direct-Drive units, unit vents, fan coil units, exhaust fans, and other fixed loads

Specifications

Application Building Automation Systems
Current Measurement Range 0.25 - 200 A
Current Sensor type Current Switch, AC
Electrical Wiring Size 24 - 14 AWG (0.2 - 2.1 mm²)
Measurement Type AC Current
Model H800
Monitored Frequency Range 50 - 60 Hz
Monitored Wire Size 0.7" (18 mm)
Mounting Solid Core
Output Specifications N.O. 1 A @ 30 VAC/DC
Outputs Switch output
Product Certification UL | CE
Setpoint Fixed

 

Datasheets

pdf logo Veris Hawkeye H800 Current Switch Data Sheet
pdf logo Veris Hawkeye H800 Current Switch Installation
pdf logo Veris Hawkeye H800 Current Switch Engineering Specifications
pdf logo Veris Hawkeye H800 Current Switch Declaration
Mounting Type:
Solid-Core
Setpoint:
Fixed Trip
Contact Type:
Normally Open
Amp Range:
0.25-200A
Trip Point:
0.25A
Contact Rating:
1.0A @ 30VAC/DC
Contact Termination:
Terminal Strip