Caleffi 250041A : Solar Air Vent 1/2" MNPT

Caleffi

MSRP: $81.20
Your Price:  $56.84
(You save $24.36 )
(No reviews yet) Write a Review
SKU:
250041A
UPC:
8.01662E+12
Condition:
New
Availability:
Ships in 1 Week
Adding to cart… The item has been added
Connection1/2" male NPT
Max Pressure150 psi
Medium Temp Range-20 to 360 deg F (-30 to 180 deg C)
Warranty2-Year Limited

The Caleffi 250041A is a solar air vent with 1/2" male NPT connections. It is used in solar thermal systems.

Best for automatic air removal at the high point of a solar collector circuit.

Specifications sourced from Caleffi North America technical literature. Last reviewed July 2026.

Key Features

Vents Air During Filling and Start-Up

A float-operated mechanism releases air as the collector loop is filled and commissioned. Caleffi instructions call for it to be installed with a shut-off valve and isolated once filling is complete.

High-Temperature Solar Duty

Built for the temperature extremes of a solar collector circuit, including stagnation, rather than standard hydronic service.

Technical Specifications

Product TypeSolar Air Vent
ApplicationSolar Thermal
Connections1/2" male NPT
Connection TypeNPT
Maximum operating pressure150 psi
Maximum air discharge pressure75 psi
Medium temperature range-20 to 360 deg F (-30 to 180 deg C)
Shipping Weight0.7 lb

Documentation

Related Products

Frequently Asked Questions

What does Caleffi 250041A do?

Caleffi 250041A vents air from a solar thermal circuit during filling and start-up. Air trapped in a collector loop blocks circulation and reduces heat transfer. Caleffi instructions call for it to be installed with a shut-off valve and isolated once the loop is filled.

Should Caleffi 250041A be left open in service?

No. Caleffi instructions call for the vent to be installed with a shut-off valve and isolated after the system is filled. Leaving it open in normal operation is not the intended use. Caleffi NA29284 is the matching shut-off valve.

Is Caleffi 250041A rated for solar stagnation temperatures?

It is built for solar thermal duty with a medium temperature range of -20 to 360 deg F (-30 to 180 deg C). Standard hydronic air vents are not rated for the temperatures a stagnating collector can reach.

What is the warranty on Caleffi 250041A?

Caleffi covers this product under its standard two-year limited warranty against defects in material and workmanship from the date of shipment. ZOT Supply is an authorized Caleffi distributor.

Caleffi 2-Year Limited Warranty. Caleffi North America warrants this product to be free from defects in material and workmanship for two years from the date of shipment, when installed and operated in accordance with published instructions. ZOT Supply is an authorized Caleffi distributor with fast nationwide and international shipping.
Application:
Solar Thermal
Product Type:
Solar Air Vent
Connection Type:
NPT
Connections:
1/2 inch male NPT
Max Operating Pressure:
150 psi
Medium Temperature Range:
-20 to 360 deg F (-30 to 180 deg C)