null Skip to main content

ACI A/ASCSX2 : Split-Core Adjustable Trip Point Current Switch, Normally-Closed (N/C), 0 to 250 A Range, 1.5 to 220 A Trip Point, 0.2 A @ 200 VAC/VDC Contact, 5-Year Warranty

ACI

Your Price:  $64.85
(No reviews yet) Write a Review
SKU:
A/ASCSX2
Condition:
New
Availability:
Ships in 3-5 Days
Adding to cart… The item has been added
Core StyleSplit-Core
Trip PointAdjustable 1.5 to 220 A
Amperage Range0 to 250 A
ContactNormally-Closed (N/C) · 0.2 A @ 200 VAC/VDC
Mounting35 mm DIN rail foot
Warranty5-Year Limited

ACI A/ASCSX2 Adjustable Trip Point Current Switch

The ACI A/ASCSX2 is a split-core AC current switch with an adjustable trip point of 1.5 to 220 A and a Normally-Closed (N/C) dry contact rated 0.2 A @ 200 VAC/VDC. It monitors 0 to 250 A and is powered entirely by induction from the conductor it monitors, so no external supply is required.

An adjustable current switch lets the installer set the trip threshold in the field, which is what makes it suitable for condition monitoring rather than simple on/off proof. Because the A/ASCSX2 trip point can be placed between the loaded and unloaded current of a driven load, it can distinguish a motor that is running normally from one that is running but has lost its belt, is slipping, has a locked rotor, or is otherwise running under- or over-loaded. ACI lists overload, underload, broken belt, belt slippage, locked rotor and equipment failure as the supported applications for adjustable current switches.

The split-core housing opens around an existing conductor, so the A/ASCSX2 can be fitted to wiring that is already terminated. ACI directs that the switch be installed on the line side of the power feeding the monitored equipment, and that all power sources be disconnected and locked out before the device is installed. That is what makes split-core the standard choice for retrofit work and for service vehicles, where one part covers most jobs.

Power for the switch is induced from the monitored conductor itself, so there is no 24 VAC or 24 VDC supply to run and no transformer to size. The unit ships with ACI's patented 35 mm DIN rail mounting foot (U.S. Patent No. 7,416,421) for panel installation.

Specifications on this page are taken from the ACI Adjustable Switches data sheet (ACS2, ACSX2, ASCS2 & ASCSX2 Series) and Installation & Operation Instructions I0000788 Rev. 12.0.

Best For

  • Belt-loss, belt-slip and locked-rotor detection where the trip point must sit between loaded and unloaded current
  • Preventative maintenance scheduling driven by measured load change
  • Motor, pump, fan and compressor run status feedback to a BMS, PLC or DDC controller
  • Proof-of-operation and run-status interlocks on air handlers and hydronic equipment
  • Runtime accumulation and basic load trending from dry-contact closures
  • Lighting circuit status and usage logging

Warranty

Five (5) Year Limited Warranty. Covered by ACI's Five (5) Year Limited Warranty. The warranty is published in the front of ACI's Sensors & Transmitters catalog and on the ACI website.

Key Features

Field-Adjustable Trip Point

Trip threshold is set in the field anywhere from 1.5 to 220 A, with 10% hysteresis typical, so the switch can be tuned to the actual load rather than a factory default.

Self-Powered by Induction

Power is induced from the monitored conductor. There is no 24 V supply to run, no transformer to size and no separate power wiring to install.

Split-Core Aperture

Opens around an existing conductor for retrofit installation without disconnecting any wiring.

Normally-Closed (N/C) Dry Contact

Rated 0.2 A @ 200 VAC/VDC, wired to a 2-position screw terminal block that is not polarity sensitive. Contact resistance is under 10 Ohms tripped and over 1 Meg Ohm open.

Patented DIN Rail Mounting Foot

Snaps directly onto 35 mm DIN rail or mounts with two #8 Tek screws, in any orientation. U.S. Patent No. 7,416,421.

Two-Colour Status LED

Red indicates current above the trip point, blue indicates current below it, which makes setting the threshold a visual operation.

Technical Specifications

ACI Item Number142370
Core StyleSplit-Core
Trip Point StyleAdjustable Trip Point
Trip Point1.5 to 220 A
Amperage Range0 to 250 A
Contact TypeNormally-Closed (N/C)
Contact Rating0.2 A @ 200 VAC/VDC
Hysteresis10% of trip point, typical
Operating Frequency Range40 Hz to 1 kHz
Status LED IndicationRed LED (current above trip point) | Blue LED (current below trip point)
Monitored Current TypeAC Current
Maximum AC Voltage600 VAC
Sensor PowerInduced from the monitored conductor
Isolation Voltage2200 VAC
Contact On Resistance | Off Resistance< 10 Ohms (tripped) | > 1 Meg Ohm (open)
Aperture Size0.75 in (19.05 mm)
DIN Rail Size35 mm (U.S. Patent No. 7,416,421)
Operating Temperature Range5 to 104 °F (-15 to 40 °C)
Operating Humidity Range0 to 95% RH, non-condensing
Recommended Storage Temperature | RH41 to 95 °F (5 to 35 °C) | 40 to 85% RH, non-condensing
Enclosure Material | Flammability RatingPC/ABS (polycarbonate / ABS blend) | UL94-V0
Wiring Connections2-position screw terminal block (not polarity sensitive)
Wire Size16 to 22 AWG (1.31 mm2 to 0.33 mm2), copper wires only
Terminal Block Torque Rating4.43 to 5.31 in-lbs (0.5 to 0.6 Nm)
Minimum Mounting Distance1 in (2.6 cm) from relays, contactors and transformers
Agency ApprovalsUL/CUL US Listed (UL 508) Industrial Control Equipment, File # E309723, CE, RoHS2, WEEE, UKCA
Product Dimensions (L x W x H)2.780 in (70.51 mm) x 3.238 in (82.25 mm) x 1.120 in (28.45 mm)
Product Weight0.266 lbs (0.121 kg)
WarrantyFive (5) Year Limited Warranty

Not intended for use in life / safety applications or in hazardous / classified locations.

Disconnect and lock out all power sources before installation. Required by the ACI Installation & Operation Instructions. Installation must be performed by qualified personnel in compliance with all national and local electrical codes.

Response Time

Current Above Trip PointResponse Time
1.50 A344 mS
10 A92 mS
20 A86 mS

Documentation

Related Products

Frequently Asked Questions

What is the trip point of the ACI A/ASCSX2?

The A/ASCSX2 trip point is 1.5 to 220 A. It is adjustable in the field over that range, with 10% hysteresis typical.

Does the ACI A/ASCSX2 need external power?

No. Power is induced from the conductor being monitored, so no 24 VAC or 24 VDC supply, transformer or power wiring is required. The two terminals carry the dry contact output only.

Is the ACI A/ASCSX2 solid-core or split-core?

The A/ASCSX2 is split-core. Split-core units open around an existing conductor and install without disconnecting any wiring, which is why they are used in retrofit work.

What is the contact rating of the ACI A/ASCSX2?

The status contact is Normally-Closed (N/C) rated 0.2 A @ 200 VAC/VDC. Contact resistance is under 10 Ohms when tripped and over 1 Meg Ohm when open.

What amperage range does the ACI A/ASCSX2 monitor?

The A/ASCSX2 monitors 0 to 250 A with a maximum conductor voltage of 600 VAC and 2200 VAC isolation.

ACI Five (5) Year Limited Warranty. This product is covered by Automation Components, Inc.’s Five (5) Year Limited Warranty, published in the front of the ACI Sensors & Transmitters catalog and on the ACI website. Warranty terms are set by the manufacturer and are subject to change without notice.

Mounting Type:
Split-Core
Setpoint:
Adjustable Trip
Contact Type:
Normally Closed
Amp Range:
0-250A
Trip Point:
1.5-220A
Contact Rating:
0.2 A @ 200 VAC/VDC
Contact Termination:
Terminal Strip
Sensor Power:
Self-Powered
Warranty: