ACI A/RH3-1K-NI-SP-05 : Wall Plate Relative Humidity Sensor, 3% Accuracy, RH Outputs: 0-5 (Default) & 0-10 VDC, 1K Nickel RTD, Wall Plate 304SS, Made in USA

ACI

MSRP: $342.00
$130.02
(You save $211.98 )
(No reviews yet) Write a Review
SKU:
A/RH3-1K-NI-SP-05
Condition:
New
Availability:
Ships in 1-2 Days
Adding to cart… The item has been added

ACI A/RH3-1K-NI-SP-05 : Wall Plate Relative Humidity Sensor, 3% Accuracy, RH Outputs: 0-5 (Default) & 0-10 VDC, 1K Nickel RTD, Wall Plate 304SS, Made in USA

The ACI Relative Humidity with Thermistor Wall Plate Series utilizes a thermoset polymer capacitive sensing element with a factory applied hygroscopic filter to deliver a proportional analog voltage output signal. The hygroscopic filter provides added resistance to moisture, dust, and other chemicals for greater long term reliability. The RH Stainless Plate transmitter features integral DIP switches for field selection of the proper output signal and supply voltage to meet your applications requirements. Each unit also contains 0%, 50%, and 100% test options to verify that the transmitter is both working and properly installed. Field calibration can be performed by using the increment and decrement calibration DIP switches without the need to replace the sensing element. These enhancements provide increased flexibility and outstanding long-term reliability. All RH Stainless Plate transmitters come standard with an attractive brushed finish stainless steel, single gang wall mounting plate and are designed to mount over a single gang junction box in the wall. The PCBs are conformally coated for added protection from moisture and other contaminants. A temporary plastic sensor cover is included to provide protection for the RH sensor from chemicals used in wash down applications.

Specifications

RH Supply Voltage (Reverse Polarity Protected):

4-20 mA: 250 Ohm Load: 15 - 40 VDC / 18 - 28 VAC | 500 Ohm Load: 18 - 40 VDC / 18 - 28 VAC

0-5 VDC: 12 - 40 VDC / 18 - 28 VAC | 0-10 VDC: 18 - 40 VDC / 18 - 28 VAC

RH Output Signal: 2-wire: 4 - 20 mA (Factory Default) | 3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable)
RH Measurement Range: 0-100%
Operating RH Range: 0 to 95% RH, non-condensing
RH Stability | Repeatability | Sensitivity: Less than 2% drift / 5 years | 0.5% RH | 0.1% RH

 

Datasheets

Sensor Type:
Wall Plate
Humidity Element:
3%
Humidity Ouput:
0-5 VDC
Temperature Element:
1K Nickel RTD
CO2 Element:
None
Display:
No Display
Supported Protocols:
None
Setpoint:
No Setpoint
Override:
No Override
Material: