Skip to main content

BAPI BA/AQX-D : Dual Channel CO2 Room Sensor for Continuously Occupied Areas, Field Selectable Voltage Output - 0 to 10V Default, 0 to 2,000 ppm Range, 5-Year Warranty

BAPI

MSRP: $425.00
$184.00
(You save $241.00 )
(No reviews yet) Write a Review
SKU:
BA/AQX-D
Condition:
New
Availability:
Ships in 1-3 Days
Adding to cart… The item has been added

BAPI BA/AQX-D : Dual Channel CO2 Room Sensor for Continuously Occupied Areas, Field Selectable Voltage Output - 0 to 10V Default, 0 to 2,000 ppm Range, 5-Year Warranty

Breathe Easy With BAPI's BA/AQX-D CO2 Sensor: Precision Air Quality Monitoring for Continuously Occupied Spaces

Maintain peak indoor air quality and optimize ventilation in your busy spaces with the BAPI BA/AQX-D CO2 sensor. This dual-channel powerhouse accurately measures CO2 levels, triggering adjustments for maximum comfort and energy efficiency.

Unmatched Performance:

  • Precise CO2 detection: Monitors ranges from 0 to 2,000 ppm, ideal for continuously occupied areas like classrooms, offices, and conference rooms.
  • Dual-channel design: Ensures reliable readings even in fluctuating environments.
  • Field-selectable voltage output (0-10V default): Seamless integration with your existing HVAC system.
  • 5-year warranty: Invest with confidence in long-lasting performance.

Effortless Convenience:

  • Automatic temperature and pressure compensation: No need for manual adjustments.
  • Multiple mounting options: Wall, ceiling, or duct placement for optimal coverage.
  • Intuitive LED indicator: Provides real-time CO2 level feedback (green for good, yellow for fair, red for poor).

Enhanced Well-being and Savings:

  • Improved indoor air quality: Reduces headaches, fatigue, and respiratory issues associated with high CO2 levels.
  • Increased occupant comfort: Maintains a fresh, healthy environment for improved productivity and learning.
  • Optimized ventilation: Reduces energy waste by adjusting ventilation based on actual CO2 needs.

Invest in the BAPI BA/AQX-D CO2 sensor for a healthier, more energy-efficient future.

Specifications

Power: 12 to 24 VDC, 240 mA • 18 to 24 VAC, 12 VA Peak
CO2 Sensing Element: Dual Channel Non-Dispersive Infrared (NDIR)
Field Selectable Voltage Output: 0 to 5 or 0 to 10 VDC
Termination:  3 Terminals, 16 to 22 AWG
Operating Environment: 32 to 122°F (0 to 50°C)
0 to 95%RH non-condensing
Enclosure Material:
ABS Plastic, Material Rated UL94 V-O
CO2 Detection Range: 0 to 2,000
Start-Up Time:
<2 Minutes
Response Time: <2 Minutes for 90% step change typical (after start-up)
Mounting: Standard 2”x4” junction box, European junction box or drywall mount (screws provided)
CO2 Accuracy: 400 to 1,000 ppm: ±75 ppm
>1,000 ppm: ±10% of reading
CO2 Drift Stability: <5% of full scale over life of product.
LED CO2 Level Indicator

(0 to 2,000 ppm units only):

  • Good, Green < 1,000 ppm
  • Fair, Yellow = 1,000 to 1,500 ppm
  • Poor, Red > 1,500 ppm
Agency: RoHS, CE, Title 24 Requirements

 

Datasheets

pdf logo BAPI CO2 Room Sensor, BAPI-Stat “Quantum” Enclosure, Datasheet for Submittal
pdf logo BAPI-Stat “Quantum” CO2 Room Sensor Instructions
pdf logo Effects of Temperature and Barometric Pressure on CO2 Measurement
pdf logo Calibration Methods for Single and Dual Beam CO2 Sensors

 

Sensor Type:
Wall
Humidity Element:
None
CO2 Element:
Yes
Temperature Element:
None
Display:
No Display
VOC: