BAPI BA/AQX-F : Dual Channel CO2 Room Sensor for Continuously Occupied Areas, Field Selectable Voltage Output - 0 to 10V Default, 0 to 5,000 ppm Range, 5-Year Warranty
Breathe Easy & Save Smart: BAPI BA/AQX-F CO2 Sensor for Optimal Indoor Air Quality.
Looking for an intelligent solution to optimize ventilation, maximize energy efficiency, and prioritize occupant well-being in continuously occupied spaces? Look no further than the BAPI BA/AQX-F CO2 Sensor!
Dual-Channel Precision, Expanded Monitoring:
- Accurately tracks CO2 levels up to 5,000 ppm, ideal for larger rooms, conference spaces, or areas with fluctuating occupancy.
- Dual-channel technology ensures reliable readings even in environments with temperature or pressure changes.
Seamless Integration & Effortless Management:
- Field-selectable voltage output (0-10V default) for smooth integration with your existing HVAC system.
- Automatic temperature and pressure compensation eliminates manual adjustments,simplifying maintenance.
- Multiple mounting options (wall, ceiling, duct placement) offer versatile installation for optimal coverage.
Enhanced Comfort & Reduced Costs:
- Maintains optimal ventilation based on real-time CO2 levels, boosting occupant comfort and reducing energy waste.
- Improves indoor air quality by minimizing CO2 buildup, leading to better health, focus, and productivity.
- Durable construction and a 5-year warranty guarantee lasting performance and peace of mind.
Invest in the BAPI BA/AQX-F CO2 Sensor and watch your indoor air quality skyrocket while your energy bills plummet!
Specifications
Power: | 12 to 24 VDC, 240 mA • 18 to 24 VAC, 12 VA Peak |
CO2 Sensing Element: | Dual Channel Non-Dispersive Infrared (NDIR) |
Field Selectable Voltage Output: | 0 to 5 or 0 to 10 VDC |
Termination: | 3 Terminals, 16 to 22 AWG |
Operating Environment: | 32 to 122°F (0 to 50°C) 0 to 95%RH non-condensing |
Enclosure Material: | ABS Plastic, Material Rated UL94 V-O |
CO2 Detection Range: | 0 to 5,000 |
Start-Up Time: | <2 Minutes |
Response Time: | <2 Minutes for 90% step change typical (after start-up) |
Mounting: | Standard 2”x4” junction box, European junction box or drywall mount (screws provided) |
CO2 Accuracy: | 400 to 1,000 ppm: ±75 ppm >1,000 ppm: ±10% of reading |
CO2 Drift Stability: | <5% of full scale over life of product. |
Agency: | RoHS, CE, Title 24 Requirements |
Datasheets
- Sensor Type:
- Wall
- Humidity Element:
- None
- CO2 Element:
- Yes
- Temperature Element:
- None
- Display:
- No Display
- VOC:
- No